{"title":"砖石集热器现代化用衬板结构分析","authors":"L. Wysocki, C. Madryas, J. Grosel","doi":"10.2478/sgem-2021-0031","DOIUrl":null,"url":null,"abstract":"Abstract Brick sewers were designed as egg-shaped, pear-shaped, bell-shaped, vaulted, and even rectangular (sometimes with granite ceilings and floor slabs). In exceptional cases, circular sections were also made of brick. Efforts were made in order to ensure optimal flow conditions, and also that the cross-section was adapted to the shape of the rock mass pressure line. This is due to the fact that the most advantageous shapes for masonry collectors are shapes in which no tensile stresses will occur in any part of the cross-section under the influence of external loads. Nevertheless, sewage conduits degrade over time. The boundary conditions of their use also change, which affects the magnitude of mechanical and hydraulic loads. Further use of a sewer in such a case requires its renewal, and less frequently, modernization that results from the necessity to change its function. This is usually done by introducing a new conduit into the interior of the renovated or modernized sewer, which in literature is called a liner. The aim of the analysis was to determine the thickness of the liners that strengthen the structures of brick channels with an inverted egg cross-section and with dimensions of 1050 × 700 mm, which are intended for gravitational sewage systems. The analysis included the performance of variant static and strength calculations for the assumption that the conduit after its modernization will be replaced with a conduit operating in the pressure system, which is a very rare requirement. It was assumed that the best solution would be to use a CIPP (Cured In Place Pipe) liner.","PeriodicalId":44626,"journal":{"name":"Studia Geotechnica et Mechanica","volume":null,"pages":null},"PeriodicalIF":0.7000,"publicationDate":"2021-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analysis of the structure of liners used for the modernisation of brick collectors\",\"authors\":\"L. Wysocki, C. Madryas, J. Grosel\",\"doi\":\"10.2478/sgem-2021-0031\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Brick sewers were designed as egg-shaped, pear-shaped, bell-shaped, vaulted, and even rectangular (sometimes with granite ceilings and floor slabs). In exceptional cases, circular sections were also made of brick. Efforts were made in order to ensure optimal flow conditions, and also that the cross-section was adapted to the shape of the rock mass pressure line. This is due to the fact that the most advantageous shapes for masonry collectors are shapes in which no tensile stresses will occur in any part of the cross-section under the influence of external loads. Nevertheless, sewage conduits degrade over time. The boundary conditions of their use also change, which affects the magnitude of mechanical and hydraulic loads. Further use of a sewer in such a case requires its renewal, and less frequently, modernization that results from the necessity to change its function. This is usually done by introducing a new conduit into the interior of the renovated or modernized sewer, which in literature is called a liner. The aim of the analysis was to determine the thickness of the liners that strengthen the structures of brick channels with an inverted egg cross-section and with dimensions of 1050 × 700 mm, which are intended for gravitational sewage systems. The analysis included the performance of variant static and strength calculations for the assumption that the conduit after its modernization will be replaced with a conduit operating in the pressure system, which is a very rare requirement. It was assumed that the best solution would be to use a CIPP (Cured In Place Pipe) liner.\",\"PeriodicalId\":44626,\"journal\":{\"name\":\"Studia Geotechnica et Mechanica\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2021-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Studia Geotechnica et Mechanica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2478/sgem-2021-0031\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"MECHANICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Studia Geotechnica et Mechanica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/sgem-2021-0031","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MECHANICS","Score":null,"Total":0}
Analysis of the structure of liners used for the modernisation of brick collectors
Abstract Brick sewers were designed as egg-shaped, pear-shaped, bell-shaped, vaulted, and even rectangular (sometimes with granite ceilings and floor slabs). In exceptional cases, circular sections were also made of brick. Efforts were made in order to ensure optimal flow conditions, and also that the cross-section was adapted to the shape of the rock mass pressure line. This is due to the fact that the most advantageous shapes for masonry collectors are shapes in which no tensile stresses will occur in any part of the cross-section under the influence of external loads. Nevertheless, sewage conduits degrade over time. The boundary conditions of their use also change, which affects the magnitude of mechanical and hydraulic loads. Further use of a sewer in such a case requires its renewal, and less frequently, modernization that results from the necessity to change its function. This is usually done by introducing a new conduit into the interior of the renovated or modernized sewer, which in literature is called a liner. The aim of the analysis was to determine the thickness of the liners that strengthen the structures of brick channels with an inverted egg cross-section and with dimensions of 1050 × 700 mm, which are intended for gravitational sewage systems. The analysis included the performance of variant static and strength calculations for the assumption that the conduit after its modernization will be replaced with a conduit operating in the pressure system, which is a very rare requirement. It was assumed that the best solution would be to use a CIPP (Cured In Place Pipe) liner.
期刊介绍:
An international journal ‘Studia Geotechnica et Mechanica’ covers new developments in the broad areas of geomechanics as well as structural mechanics. The journal welcomes contributions dealing with original theoretical, numerical as well as experimental work. The following topics are of special interest: Constitutive relations for geomaterials (soils, rocks, concrete, etc.) Modeling of mechanical behaviour of heterogeneous materials at different scales Analysis of coupled thermo-hydro-chemo-mechanical problems Modeling of instabilities and localized deformation Experimental investigations of material properties at different scales Numerical algorithms: formulation and performance Application of numerical techniques to analysis of problems involving foundations, underground structures, slopes and embankment Risk and reliability analysis Analysis of concrete and masonry structures Modeling of case histories