叶轮诱发的不间断室性心动过速

IF 1.3 Q2 MEDICINE, GENERAL & INTERNAL
Amir Kaki, A. Subahi, Mohamed Shokr, Walid Ibrahim, A. Yassin, R. Hasan, M. Alraies, T. Schreiber
{"title":"叶轮诱发的不间断室性心动过速","authors":"Amir Kaki, A. Subahi, Mohamed Shokr, Walid Ibrahim, A. Yassin, R. Hasan, M. Alraies, T. Schreiber","doi":"10.31486/toj.18.0018","DOIUrl":null,"url":null,"abstract":"Background: The Impella 2.5 and Impella Cardiac Power (CP) devices (ABIOMED) are used to provide mechanical circulatory support for high-risk percutaneous coronary interventions or cardiogenic shock as a bridge to recovery or destination therapy. The Impella device has shown both efficacy and safety in patients presenting with cardiogenic shock. Performing clinical and hemodynamic assessments of patients presenting with cardiogenic shock is an important step to determine if mechanical circulatory support with an Impella device is indicated. Case Report: A 62-year-old male presented with cardiogenic shock requiring Impella device support. Two days later, the patient developed incessant ventricular tachycardia. Transthoracic echocardiography showed that the Impella device had migrated out of the ventricular cavity. Once the position of the Impella device was adjusted, ventricular tachycardia immediately resolved. Conclusion: Our case emphasizes the importance of using imaging modalities such as transthoracic echocardiography to ensure correct positioning of an Impella device in the left ventricle to avoid complications.","PeriodicalId":47600,"journal":{"name":"Ochsner Journal","volume":"19 1","pages":"248 - 251"},"PeriodicalIF":1.3000,"publicationDate":"2019-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Impella-Induced Incessant Ventricular Tachycardia\",\"authors\":\"Amir Kaki, A. Subahi, Mohamed Shokr, Walid Ibrahim, A. Yassin, R. Hasan, M. Alraies, T. Schreiber\",\"doi\":\"10.31486/toj.18.0018\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: The Impella 2.5 and Impella Cardiac Power (CP) devices (ABIOMED) are used to provide mechanical circulatory support for high-risk percutaneous coronary interventions or cardiogenic shock as a bridge to recovery or destination therapy. The Impella device has shown both efficacy and safety in patients presenting with cardiogenic shock. Performing clinical and hemodynamic assessments of patients presenting with cardiogenic shock is an important step to determine if mechanical circulatory support with an Impella device is indicated. Case Report: A 62-year-old male presented with cardiogenic shock requiring Impella device support. Two days later, the patient developed incessant ventricular tachycardia. Transthoracic echocardiography showed that the Impella device had migrated out of the ventricular cavity. Once the position of the Impella device was adjusted, ventricular tachycardia immediately resolved. Conclusion: Our case emphasizes the importance of using imaging modalities such as transthoracic echocardiography to ensure correct positioning of an Impella device in the left ventricle to avoid complications.\",\"PeriodicalId\":47600,\"journal\":{\"name\":\"Ochsner Journal\",\"volume\":\"19 1\",\"pages\":\"248 - 251\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2019-03-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ochsner Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31486/toj.18.0018\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ochsner Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31486/toj.18.0018","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 4

摘要

背景:Impella 2.5和Impella Cardiac Power (CP)装置(ABIOMED)用于为高风险经皮冠状动脉介入治疗或心源性休克提供机械循环支持,作为恢复或终点治疗的桥梁。Impella装置在出现心源性休克的患者中显示出有效性和安全性。对出现心源性休克的患者进行临床和血流动力学评估是确定是否需要使用Impella装置进行机械循环支持的重要步骤。病例报告:一名62岁男性表现为心源性休克,需要Impella设备支持。两天后,患者出现不间断室性心动过速。经胸超声心动图显示Impella装置已移出心室腔。一旦调整了Impella装置的位置,室性心动过速立即得到解决。结论:我们的病例强调了使用诸如经胸超声心动图等成像方式来确保Impella装置在左心室的正确定位以避免并发症的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Impella-Induced Incessant Ventricular Tachycardia
Background: The Impella 2.5 and Impella Cardiac Power (CP) devices (ABIOMED) are used to provide mechanical circulatory support for high-risk percutaneous coronary interventions or cardiogenic shock as a bridge to recovery or destination therapy. The Impella device has shown both efficacy and safety in patients presenting with cardiogenic shock. Performing clinical and hemodynamic assessments of patients presenting with cardiogenic shock is an important step to determine if mechanical circulatory support with an Impella device is indicated. Case Report: A 62-year-old male presented with cardiogenic shock requiring Impella device support. Two days later, the patient developed incessant ventricular tachycardia. Transthoracic echocardiography showed that the Impella device had migrated out of the ventricular cavity. Once the position of the Impella device was adjusted, ventricular tachycardia immediately resolved. Conclusion: Our case emphasizes the importance of using imaging modalities such as transthoracic echocardiography to ensure correct positioning of an Impella device in the left ventricle to avoid complications.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Ochsner Journal
Ochsner Journal MEDICINE, GENERAL & INTERNAL-
CiteScore
2.10
自引率
0.00%
发文量
71
审稿时长
24 weeks
期刊介绍: The Ochsner Journal is a quarterly publication designed to support Ochsner"s mission to improve the health of our community through a commitment to innovation in healthcare, medical research, and education. The Ochsner Journal provides an active dialogue on practice standards in today"s changing healthcare environment. Emphasis will be given to topics of great societal and medical significance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信