{"title":"提高运输系统的运行时间效率,减少运输系统的维护时间","authors":"","doi":"10.46544/ams.v27i3.12","DOIUrl":null,"url":null,"abstract":"The Gremikhinsky oil field contains heavy-grade, high-sulfur, high-resinous, paraffin-base crude oil, and the produced reservoir fluid is highly corrosive. All this results in the formation of asphaltene-resin-paraffin deposits (ARPD) and stable oil-water emulsions, which in turn leads to premature failure of downhole pumping equipment. In this work, the scope of measures to prevent malfunctions of pumping units is considered. The use of the SONKOR-9701 inhibitor through a special design of the ESP power cable with a capillary conveying line for supplying the chemical reagent to the reception delivers the chemical reagent directly to the required entry point with the most effective dosage and ensures a prompt change of the dosage and type of the reagent. With this technology, the reagent is not consumed for the repletion of the oil column in the annular space; its adsorption is on the surface of the casing and tubing. Thus, the reagent targeted with just specific technological causes and the greatest effect is ensured. Due to the introduction of a special cable with a capillary conveying line, it is planned to increase the average operating time for failure and, consequently, reduce the maintenance job at the Gremikhinsky oil field. It is also predicted the additional volume of extraction because of a special submersible cable device (SSCD), as well as by increasing the delivery (capacity) rate of the pump.","PeriodicalId":50889,"journal":{"name":"Acta Montanistica Slovaca","volume":" ","pages":""},"PeriodicalIF":2.2000,"publicationDate":"2022-12-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Increasing the efficiency of operating time and reducing maintenance time of transport systems\",\"authors\":\"\",\"doi\":\"10.46544/ams.v27i3.12\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The Gremikhinsky oil field contains heavy-grade, high-sulfur, high-resinous, paraffin-base crude oil, and the produced reservoir fluid is highly corrosive. All this results in the formation of asphaltene-resin-paraffin deposits (ARPD) and stable oil-water emulsions, which in turn leads to premature failure of downhole pumping equipment. In this work, the scope of measures to prevent malfunctions of pumping units is considered. The use of the SONKOR-9701 inhibitor through a special design of the ESP power cable with a capillary conveying line for supplying the chemical reagent to the reception delivers the chemical reagent directly to the required entry point with the most effective dosage and ensures a prompt change of the dosage and type of the reagent. With this technology, the reagent is not consumed for the repletion of the oil column in the annular space; its adsorption is on the surface of the casing and tubing. Thus, the reagent targeted with just specific technological causes and the greatest effect is ensured. Due to the introduction of a special cable with a capillary conveying line, it is planned to increase the average operating time for failure and, consequently, reduce the maintenance job at the Gremikhinsky oil field. It is also predicted the additional volume of extraction because of a special submersible cable device (SSCD), as well as by increasing the delivery (capacity) rate of the pump.\",\"PeriodicalId\":50889,\"journal\":{\"name\":\"Acta Montanistica Slovaca\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2022-12-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Montanistica Slovaca\",\"FirstCategoryId\":\"89\",\"ListUrlMain\":\"https://doi.org/10.46544/ams.v27i3.12\",\"RegionNum\":4,\"RegionCategory\":\"地球科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"GEOSCIENCES, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Montanistica Slovaca","FirstCategoryId":"89","ListUrlMain":"https://doi.org/10.46544/ams.v27i3.12","RegionNum":4,"RegionCategory":"地球科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"GEOSCIENCES, MULTIDISCIPLINARY","Score":null,"Total":0}
Increasing the efficiency of operating time and reducing maintenance time of transport systems
The Gremikhinsky oil field contains heavy-grade, high-sulfur, high-resinous, paraffin-base crude oil, and the produced reservoir fluid is highly corrosive. All this results in the formation of asphaltene-resin-paraffin deposits (ARPD) and stable oil-water emulsions, which in turn leads to premature failure of downhole pumping equipment. In this work, the scope of measures to prevent malfunctions of pumping units is considered. The use of the SONKOR-9701 inhibitor through a special design of the ESP power cable with a capillary conveying line for supplying the chemical reagent to the reception delivers the chemical reagent directly to the required entry point with the most effective dosage and ensures a prompt change of the dosage and type of the reagent. With this technology, the reagent is not consumed for the repletion of the oil column in the annular space; its adsorption is on the surface of the casing and tubing. Thus, the reagent targeted with just specific technological causes and the greatest effect is ensured. Due to the introduction of a special cable with a capillary conveying line, it is planned to increase the average operating time for failure and, consequently, reduce the maintenance job at the Gremikhinsky oil field. It is also predicted the additional volume of extraction because of a special submersible cable device (SSCD), as well as by increasing the delivery (capacity) rate of the pump.
期刊介绍:
Acta Montanistica Slovaca publishes high quality articles on basic and applied research in the following fields:
geology and geological survey;
mining;
Earth resources;
underground engineering and geotechnics;
mining mechanization, mining transport, deep hole drilling;
ecotechnology and mineralurgy;
process control, automation and applied informatics in raw materials extraction, utilization and processing;
other similar fields.
Acta Montanistica Slovaca is the only scientific journal of this kind in Central, Eastern and South Eastern Europe.
The submitted manuscripts should contribute significantly to the international literature, even if the focus can be regional. Manuscripts should cite the extant and relevant international literature, should clearly state what the wider contribution is (e.g. a novel discovery, application of a new technique or methodology, application of an existing methodology to a new problem), and should discuss the importance of the work in the international context.