Fangzhou Zhao, Xiongfei Wang, Zichao Zhou, L. Meng, J. Hasler, J. Svensson, L. Kocewiak, Haofeng Bai, Hongyang Zhang
{"title":"风力发电厂的储能增强型statcom","authors":"Fangzhou Zhao, Xiongfei Wang, Zichao Zhou, L. Meng, J. Hasler, J. Svensson, L. Kocewiak, Haofeng Bai, Hongyang Zhang","doi":"10.1109/MPEL.2023.3273893","DOIUrl":null,"url":null,"abstract":"The past years have seen a rapid increase in the deployment of large-scale wind power plants (WPPs) in transmission grids. The dynamic interactions between wind turbines (WTs), power transmission cables, and other electrical infrastructure of WPPs pose challenges to the stability and quality of electricity supply, particularly under diverse grid conditions. The interactions tend to be worsened with longer transmission cables <xref ref-type=\"bibr\" rid=\"ref1\">[1]</xref>. A harmonic instability issue that features a 451 Hz resonance is manifested in an offshore WPP located in the North Sea <xref ref-type=\"bibr\" rid=\"ref2\">[2]</xref>. During a submarine cable outage, an offshore WPP situated in England encountered instability due to sub-synchronous resonance at around 8.5 Hz <xref ref-type=\"bibr\" rid=\"ref3\">[3]</xref>.","PeriodicalId":13049,"journal":{"name":"IEEE Power Electronics Magazine","volume":"10 1","pages":"34-39"},"PeriodicalIF":2.6000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Energy-Storage Enhanced STATCOMs for Wind Power Plants\",\"authors\":\"Fangzhou Zhao, Xiongfei Wang, Zichao Zhou, L. Meng, J. Hasler, J. Svensson, L. Kocewiak, Haofeng Bai, Hongyang Zhang\",\"doi\":\"10.1109/MPEL.2023.3273893\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The past years have seen a rapid increase in the deployment of large-scale wind power plants (WPPs) in transmission grids. The dynamic interactions between wind turbines (WTs), power transmission cables, and other electrical infrastructure of WPPs pose challenges to the stability and quality of electricity supply, particularly under diverse grid conditions. The interactions tend to be worsened with longer transmission cables <xref ref-type=\\\"bibr\\\" rid=\\\"ref1\\\">[1]</xref>. A harmonic instability issue that features a 451 Hz resonance is manifested in an offshore WPP located in the North Sea <xref ref-type=\\\"bibr\\\" rid=\\\"ref2\\\">[2]</xref>. During a submarine cable outage, an offshore WPP situated in England encountered instability due to sub-synchronous resonance at around 8.5 Hz <xref ref-type=\\\"bibr\\\" rid=\\\"ref3\\\">[3]</xref>.\",\"PeriodicalId\":13049,\"journal\":{\"name\":\"IEEE Power Electronics Magazine\",\"volume\":\"10 1\",\"pages\":\"34-39\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2023-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Power Electronics Magazine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MPEL.2023.3273893\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Power Electronics Magazine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MPEL.2023.3273893","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
Energy-Storage Enhanced STATCOMs for Wind Power Plants
The past years have seen a rapid increase in the deployment of large-scale wind power plants (WPPs) in transmission grids. The dynamic interactions between wind turbines (WTs), power transmission cables, and other electrical infrastructure of WPPs pose challenges to the stability and quality of electricity supply, particularly under diverse grid conditions. The interactions tend to be worsened with longer transmission cables [1]. A harmonic instability issue that features a 451 Hz resonance is manifested in an offshore WPP located in the North Sea [2]. During a submarine cable outage, an offshore WPP situated in England encountered instability due to sub-synchronous resonance at around 8.5 Hz [3].