高效液相色谱法同时测定甲氨蝶呤和非甾体类抗炎药的含量

Makoto Takada, Y. Ohba, T. Kabashima, K. Nakashima, M. Wada
{"title":"高效液相色谱法同时测定甲氨蝶呤和非甾体类抗炎药的含量","authors":"Makoto Takada, Y. Ohba, T. Kabashima, K. Nakashima, M. Wada","doi":"10.15583/jpchrom.2020.009","DOIUrl":null,"url":null,"abstract":"The combination of methotrexate (MTX) and non-steroidal anti-inflammatory drugs (NSAIDs), which is frequently used for rheumatoid arthritis (RA) treatment, courses of adverse events. To prevent these, simultaneous monitoring of these compounds is available. Therefore, we developed a new method for MTX and NSAIDs such as loxoprofen (LP), meloxicam (MX), lornoxicam (LX), diclofenac (DF) and celecoxib (CX) determination using HPLC with simple pretreatment of human serum sample. The separation of MTX and 5 NSAIDs was performed on C6-Phenyl column with gradient elution using 10 mmol/L ammonium acetate aqueous solution and methanol, and achieved within 25 min of analytical runtime. Calibration curves using standards showed good linearity ( r 2 >0.9998) in the range of 0.02-500 pmol/10 μL injection for MTX, 10-500 pmol for LP, 0.2-500 pmol for MX and DF, 0.05-500 pmol for LX and 2-500 pmol for CX. The detection limits of the proposed method were at least less than 96.0 fmol, and repeatability was less than 4.62 RSD%. In addition, acceptable precision of less than 10.19 RSD% and recovery of more than 54.4% of the method were obtained because the peaks of MTX and NSAIDs could be well-separated from those of interferings in serum. the method be useful to avoid occurring adverse events, and confirm the curative effect of MTX and NSAIDs.","PeriodicalId":91226,"journal":{"name":"Chromatography (Basel)","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Simple Simultaneous Assay of Methotrexate and Non-Steroidal Anti-Inflammatory Drugs by HPLC\",\"authors\":\"Makoto Takada, Y. Ohba, T. Kabashima, K. Nakashima, M. Wada\",\"doi\":\"10.15583/jpchrom.2020.009\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The combination of methotrexate (MTX) and non-steroidal anti-inflammatory drugs (NSAIDs), which is frequently used for rheumatoid arthritis (RA) treatment, courses of adverse events. To prevent these, simultaneous monitoring of these compounds is available. Therefore, we developed a new method for MTX and NSAIDs such as loxoprofen (LP), meloxicam (MX), lornoxicam (LX), diclofenac (DF) and celecoxib (CX) determination using HPLC with simple pretreatment of human serum sample. The separation of MTX and 5 NSAIDs was performed on C6-Phenyl column with gradient elution using 10 mmol/L ammonium acetate aqueous solution and methanol, and achieved within 25 min of analytical runtime. Calibration curves using standards showed good linearity ( r 2 >0.9998) in the range of 0.02-500 pmol/10 μL injection for MTX, 10-500 pmol for LP, 0.2-500 pmol for MX and DF, 0.05-500 pmol for LX and 2-500 pmol for CX. The detection limits of the proposed method were at least less than 96.0 fmol, and repeatability was less than 4.62 RSD%. In addition, acceptable precision of less than 10.19 RSD% and recovery of more than 54.4% of the method were obtained because the peaks of MTX and NSAIDs could be well-separated from those of interferings in serum. the method be useful to avoid occurring adverse events, and confirm the curative effect of MTX and NSAIDs.\",\"PeriodicalId\":91226,\"journal\":{\"name\":\"Chromatography (Basel)\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-06-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Chromatography (Basel)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15583/jpchrom.2020.009\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chromatography (Basel)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15583/jpchrom.2020.009","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

甲氨蝶呤(MTX)与非甾体抗炎药(NSAIDs)联合使用,常用于类风湿关节炎(RA)的治疗,疗程不良事件。为了防止这些,可以同时监测这些化合物。因此,我们建立了一种高效液相色谱法测定MTX和非甾体抗炎药loxoprofen (LP)、meloxicam (MX)、lornoxicam (LX)、双氯芬酸(DF)和塞来昔布(CX)的新方法。MTX和5种NSAIDs在c6 -苯基柱上进行分离,用10 mmol/L乙酸铵水溶液和甲醇梯度洗脱,分析时间为25 min。MTX在0.02 ~ 500 pmol/10 μL范围内、LP在10 ~ 500 pmol范围内、MX和DF在0.2 ~ 500 pmol范围内、LX在0.05 ~ 500 pmol范围内、CX在2 ~ 500 pmol范围内呈良好的线性关系(r = 0.9998)。方法的检出限至少小于96.0 fmol,重复性小于4.62 RSD%。此外,由于MTX和NSAIDs的峰与血清中干扰物的峰能够很好地分离,该方法的精密度小于10.19 RSD%,回收率大于54.4%。该方法有助于避免不良事件的发生,确认甲氨蝶呤与非甾体抗炎药的疗效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Simple Simultaneous Assay of Methotrexate and Non-Steroidal Anti-Inflammatory Drugs by HPLC
The combination of methotrexate (MTX) and non-steroidal anti-inflammatory drugs (NSAIDs), which is frequently used for rheumatoid arthritis (RA) treatment, courses of adverse events. To prevent these, simultaneous monitoring of these compounds is available. Therefore, we developed a new method for MTX and NSAIDs such as loxoprofen (LP), meloxicam (MX), lornoxicam (LX), diclofenac (DF) and celecoxib (CX) determination using HPLC with simple pretreatment of human serum sample. The separation of MTX and 5 NSAIDs was performed on C6-Phenyl column with gradient elution using 10 mmol/L ammonium acetate aqueous solution and methanol, and achieved within 25 min of analytical runtime. Calibration curves using standards showed good linearity ( r 2 >0.9998) in the range of 0.02-500 pmol/10 μL injection for MTX, 10-500 pmol for LP, 0.2-500 pmol for MX and DF, 0.05-500 pmol for LX and 2-500 pmol for CX. The detection limits of the proposed method were at least less than 96.0 fmol, and repeatability was less than 4.62 RSD%. In addition, acceptable precision of less than 10.19 RSD% and recovery of more than 54.4% of the method were obtained because the peaks of MTX and NSAIDs could be well-separated from those of interferings in serum. the method be useful to avoid occurring adverse events, and confirm the curative effect of MTX and NSAIDs.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信