咪唑离子包被三硫醇键合二氧化硅毛细管离子色谱法测定无机阴离子

Anang Sedyohutomo, Hiroshi Suzuki, C. Fujimoto
{"title":"咪唑离子包被三硫醇键合二氧化硅毛细管离子色谱法测定无机阴离子","authors":"Anang Sedyohutomo, Hiroshi Suzuki, C. Fujimoto","doi":"10.15583/jpchrom.2021.009","DOIUrl":null,"url":null,"abstract":"This paper describes the separation and detection of five inorganic anions (I - , BrO 3- , NO 2- , Br - , and NO 3- ) by capillary ion chromatography using 1-alkyl-3-methylimidazolium-coated columns and UV detection at 210 nm. The salts of imidazolium (IM) ions (C2-, C4-, C6-, C8-, C10-, and C18-IMs) are a family of ionic liquids and were newly examined as permanent coating reagents on a triacontyl (C30) -bonded silica reversed phase column. When 40 mM NaCl aqueous solution was used as an eluent, the elution time of these anions was increased with the length of alkyl chain between C2- and C10-IMs, but turned to decrease with C18-IM. Good and faster separations were attained using a C18-IM-coated column with 150 mM NaCl in 25%(v/v) acetonitrile-75%(v/v) water. The method was successfully applied to the determination of nitrite, bromide, and nitrate in seawater and river water.","PeriodicalId":91226,"journal":{"name":"Chromatography (Basel)","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-08-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"The Utilization of Triacontyl-Bonded Silica Coated with Imidazolium Ions for Capillary Ion Chromatographic Determination of Inorganic Anions\",\"authors\":\"Anang Sedyohutomo, Hiroshi Suzuki, C. Fujimoto\",\"doi\":\"10.15583/jpchrom.2021.009\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes the separation and detection of five inorganic anions (I - , BrO 3- , NO 2- , Br - , and NO 3- ) by capillary ion chromatography using 1-alkyl-3-methylimidazolium-coated columns and UV detection at 210 nm. The salts of imidazolium (IM) ions (C2-, C4-, C6-, C8-, C10-, and C18-IMs) are a family of ionic liquids and were newly examined as permanent coating reagents on a triacontyl (C30) -bonded silica reversed phase column. When 40 mM NaCl aqueous solution was used as an eluent, the elution time of these anions was increased with the length of alkyl chain between C2- and C10-IMs, but turned to decrease with C18-IM. Good and faster separations were attained using a C18-IM-coated column with 150 mM NaCl in 25%(v/v) acetonitrile-75%(v/v) water. The method was successfully applied to the determination of nitrite, bromide, and nitrate in seawater and river water.\",\"PeriodicalId\":91226,\"journal\":{\"name\":\"Chromatography (Basel)\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-08-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Chromatography (Basel)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15583/jpchrom.2021.009\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chromatography (Basel)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15583/jpchrom.2021.009","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文介绍了用1-烷基-3-甲基咪唑涂层毛细管离子色谱柱和210nm紫外检测法分离和检测五种无机阴离子(I-、BrO3-、NO2-、Br-和NO3-)。咪唑鎓(IM)离子的盐(C2-、C4-、C6-、C8-、C10-和C18-IM)是一类离子液体,最近在三酰基(C30)键合的二氧化硅反相柱上作为永久涂层试剂进行了检测。当使用40mM NaCl水溶液作为洗脱剂时,这些阴离子的洗脱时间随着C2-和C10-IM之间的烷基链的长度而增加,但随着C18-IM的增加而减少。使用C18 IM涂布柱,在25%(v/v)乙腈-75%(v/v。该方法已成功应用于海水和河水中亚硝酸盐、溴化物和硝酸盐的测定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Utilization of Triacontyl-Bonded Silica Coated with Imidazolium Ions for Capillary Ion Chromatographic Determination of Inorganic Anions
This paper describes the separation and detection of five inorganic anions (I - , BrO 3- , NO 2- , Br - , and NO 3- ) by capillary ion chromatography using 1-alkyl-3-methylimidazolium-coated columns and UV detection at 210 nm. The salts of imidazolium (IM) ions (C2-, C4-, C6-, C8-, C10-, and C18-IMs) are a family of ionic liquids and were newly examined as permanent coating reagents on a triacontyl (C30) -bonded silica reversed phase column. When 40 mM NaCl aqueous solution was used as an eluent, the elution time of these anions was increased with the length of alkyl chain between C2- and C10-IMs, but turned to decrease with C18-IM. Good and faster separations were attained using a C18-IM-coated column with 150 mM NaCl in 25%(v/v) acetonitrile-75%(v/v) water. The method was successfully applied to the determination of nitrite, bromide, and nitrate in seawater and river water.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信