带稳定钢板的动力髋螺钉治疗不稳定转子间骨折:一个病例系列

IF 0.2 Q4 ORTHOPEDICS
Sherif Adel Lotfy, Tarek El Nor, Mohamed Romeih
{"title":"带稳定钢板的动力髋螺钉治疗不稳定转子间骨折:一个病例系列","authors":"Sherif Adel Lotfy, Tarek El Nor, Mohamed Romeih","doi":"10.1097/BCO.0000000000001168","DOIUrl":null,"url":null,"abstract":"Background: Unstable intertrochanteric fractures represent about 60% of all trochanteric fractures. Dynamic hip screw alone in an unstable fracture pattern has a high failure rate of about 50%. Proximal femoral nail is technically a difficult surgery and has complications including nail failure, femoral shaft fracture, malreduction, screw cut-out, and nonunion. Putting a buttress like a trochanteric-stabilization plate acts as a support to the dynamic hip screw and gives good lateral wall buttress, which prevents excessive shaft medialization. Methods: Twenty-one patients with closed unstable trochanteric fractures were treated by dynamic hip screw with trochanteric stabilization plate. Results: According to the modified Harris Hip Scoring system, 11 patients had excellent results, five patients had good results, four patients had fair results, and one patient had a poor result. Conclusions: The dynamic hip screw with trochanteric stabilization plate provides a stable construct for unstable intertrochanteric fractures as it gives a good lateral wall buttress which prevents excessive fracture collapse, femoral shaft medialization, and consecutive limb shortening. It effectively supports the unstable greater trochanteric fragment and can maintain the lever arm with adequate abductor strength. Level of Evidence: Level IV.","PeriodicalId":10732,"journal":{"name":"Current Orthopaedic Practice","volume":"33 1","pages":"530 - 537"},"PeriodicalIF":0.2000,"publicationDate":"2022-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Dynamic hip screw with stabilization plate in unstable intertrochanteric fractures: a case series\",\"authors\":\"Sherif Adel Lotfy, Tarek El Nor, Mohamed Romeih\",\"doi\":\"10.1097/BCO.0000000000001168\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Unstable intertrochanteric fractures represent about 60% of all trochanteric fractures. Dynamic hip screw alone in an unstable fracture pattern has a high failure rate of about 50%. Proximal femoral nail is technically a difficult surgery and has complications including nail failure, femoral shaft fracture, malreduction, screw cut-out, and nonunion. Putting a buttress like a trochanteric-stabilization plate acts as a support to the dynamic hip screw and gives good lateral wall buttress, which prevents excessive shaft medialization. Methods: Twenty-one patients with closed unstable trochanteric fractures were treated by dynamic hip screw with trochanteric stabilization plate. Results: According to the modified Harris Hip Scoring system, 11 patients had excellent results, five patients had good results, four patients had fair results, and one patient had a poor result. Conclusions: The dynamic hip screw with trochanteric stabilization plate provides a stable construct for unstable intertrochanteric fractures as it gives a good lateral wall buttress which prevents excessive fracture collapse, femoral shaft medialization, and consecutive limb shortening. It effectively supports the unstable greater trochanteric fragment and can maintain the lever arm with adequate abductor strength. Level of Evidence: Level IV.\",\"PeriodicalId\":10732,\"journal\":{\"name\":\"Current Orthopaedic Practice\",\"volume\":\"33 1\",\"pages\":\"530 - 537\"},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2022-08-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current Orthopaedic Practice\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1097/BCO.0000000000001168\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Orthopaedic Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/BCO.0000000000001168","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

背景:不稳定转子间骨折约占所有转子间骨折的60%。在不稳定骨折模式中单独使用动力髋螺钉的失败率高达50%左右。股骨近端钉在技术上是一项困难的手术,其并发症包括钉失败、股骨干骨折、复位不良、螺钉切除和骨不连。放置一个像转子稳定板一样的支撑物作为动力髋螺钉的支撑,并提供良好的侧壁支撑,防止过度的轴内侧化。方法:对21例闭合性不稳定大转子骨折采用动力髋螺钉加大转子稳定板治疗。结果:根据改良的Harris髋关节评分系统,11名患者成绩优异,5名患者成绩良好,4名患者成绩尚可,1名患者成绩较差。结论:带转子稳定板的动力髋螺钉为不稳定的转子间骨折提供了一种稳定的结构,因为它提供了良好的侧壁支撑,可以防止骨折过度塌陷、股骨干内侧化和连续缩短肢体。它能有效支撑不稳定的大转子碎片,并能保持杠杆臂足够的外展力量。证据级别:四级。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Dynamic hip screw with stabilization plate in unstable intertrochanteric fractures: a case series
Background: Unstable intertrochanteric fractures represent about 60% of all trochanteric fractures. Dynamic hip screw alone in an unstable fracture pattern has a high failure rate of about 50%. Proximal femoral nail is technically a difficult surgery and has complications including nail failure, femoral shaft fracture, malreduction, screw cut-out, and nonunion. Putting a buttress like a trochanteric-stabilization plate acts as a support to the dynamic hip screw and gives good lateral wall buttress, which prevents excessive shaft medialization. Methods: Twenty-one patients with closed unstable trochanteric fractures were treated by dynamic hip screw with trochanteric stabilization plate. Results: According to the modified Harris Hip Scoring system, 11 patients had excellent results, five patients had good results, four patients had fair results, and one patient had a poor result. Conclusions: The dynamic hip screw with trochanteric stabilization plate provides a stable construct for unstable intertrochanteric fractures as it gives a good lateral wall buttress which prevents excessive fracture collapse, femoral shaft medialization, and consecutive limb shortening. It effectively supports the unstable greater trochanteric fragment and can maintain the lever arm with adequate abductor strength. Level of Evidence: Level IV.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.60
自引率
0.00%
发文量
107
期刊介绍: Lippincott Williams & Wilkins is a leading international publisher of professional health information for physicians, nurses, specialized clinicians and students. For a complete listing of titles currently published by Lippincott Williams & Wilkins and detailed information about print, online, and other offerings, please visit the LWW Online Store. Current Orthopaedic Practice is a peer-reviewed, general orthopaedic journal that translates clinical research into best practices for diagnosing, treating, and managing musculoskeletal disorders. The journal publishes original articles in the form of clinical research, invited special focus reviews and general reviews, as well as original articles on innovations in practice, case reports, point/counterpoint, and diagnostic imaging.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信