{"title":"真空干燥法制备阳离子聚合物涂层微通道中阳离子分析物的LVSEP分析","authors":"F. Kitagawa, Yuka Niimiya, Isoshi Nukatsuka","doi":"10.15583/JPCHROM.2021.008","DOIUrl":null,"url":null,"abstract":"To improve the detection sensitivity of cationic analytes with simple experimental procedures in microchip electrophoresis (MCE), large-volume sample stacking with an electroosmotic flow (EOF) pump (LVSEP) was performed in polymer-coated microchannels. At first, cationic polybrene (PB) was employed as the coating polymer to reverse the EOF. In the LVSEP analyses, however, the PB-coated microchannel gave insufficient enrichments and broader peaks for cationic standard dyes. By the application of neutral poly(vinyl alcohol) and cationic poly(allylamine) mixture-coating, on the other hand, good enrichments of histamine were achieved by LVSEP with a sensitive enhancement factor of 120.","PeriodicalId":91226,"journal":{"name":"Chromatography (Basel)","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-04-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"LVSEP Analysis of Cationic Analytes in Cationic Polymer-Coating Microchannel Prepared by Vacuum-Drying Method\",\"authors\":\"F. Kitagawa, Yuka Niimiya, Isoshi Nukatsuka\",\"doi\":\"10.15583/JPCHROM.2021.008\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To improve the detection sensitivity of cationic analytes with simple experimental procedures in microchip electrophoresis (MCE), large-volume sample stacking with an electroosmotic flow (EOF) pump (LVSEP) was performed in polymer-coated microchannels. At first, cationic polybrene (PB) was employed as the coating polymer to reverse the EOF. In the LVSEP analyses, however, the PB-coated microchannel gave insufficient enrichments and broader peaks for cationic standard dyes. By the application of neutral poly(vinyl alcohol) and cationic poly(allylamine) mixture-coating, on the other hand, good enrichments of histamine were achieved by LVSEP with a sensitive enhancement factor of 120.\",\"PeriodicalId\":91226,\"journal\":{\"name\":\"Chromatography (Basel)\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-04-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Chromatography (Basel)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15583/JPCHROM.2021.008\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chromatography (Basel)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15583/JPCHROM.2021.008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
LVSEP Analysis of Cationic Analytes in Cationic Polymer-Coating Microchannel Prepared by Vacuum-Drying Method
To improve the detection sensitivity of cationic analytes with simple experimental procedures in microchip electrophoresis (MCE), large-volume sample stacking with an electroosmotic flow (EOF) pump (LVSEP) was performed in polymer-coated microchannels. At first, cationic polybrene (PB) was employed as the coating polymer to reverse the EOF. In the LVSEP analyses, however, the PB-coated microchannel gave insufficient enrichments and broader peaks for cationic standard dyes. By the application of neutral poly(vinyl alcohol) and cationic poly(allylamine) mixture-coating, on the other hand, good enrichments of histamine were achieved by LVSEP with a sensitive enhancement factor of 120.