类纤维素的降解分析

IF 0.2 4区 化学 Q4 CHEMISTRY, ANALYTICAL
T. Ohshiro, Y. Aoyanagi, E. Yamada, F. Ohishi, Y. Nishimoto
{"title":"类纤维素的降解分析","authors":"T. Ohshiro, Y. Aoyanagi, E. Yamada, F. Ohishi, Y. Nishimoto","doi":"10.2116/bunsekikagaku.71.523","DOIUrl":null,"url":null,"abstract":"As a basic study of the degradation analysis of celluloid, TG measurement and FT-IR measurement by the ATR method were performed on a celluloid sheet irradiated with a xenon lamp and ultraviolet rays, and the results were compared with the cellulose acetate sheet. Celluloid showed a decrease in the thermal decomposition start temperature, and cellulose acetate showed an increase. Information on the deterioration of the sample surface was obtained from the pyrolysis start temperature and the IR spectrum of the surface, and information on the deterioration inside the sample was obtained from the peak temperature of DTG. The results were applied to the actual sample saved. Each celluloid sample was degraded by light, and the degree of degradation was considered to be similar to the change when a 0.2 mm thick sheet was irradiated with a xenon lamp for 8 hours. By devising the measurement conditions, it was confirmed that TG/DTA measurement and celluloid sample are effective measurement methods.","PeriodicalId":9521,"journal":{"name":"Bunseki Kagaku","volume":null,"pages":null},"PeriodicalIF":0.2000,"publicationDate":"2022-09-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Degradation Analysis of Celluloid\",\"authors\":\"T. Ohshiro, Y. Aoyanagi, E. Yamada, F. Ohishi, Y. Nishimoto\",\"doi\":\"10.2116/bunsekikagaku.71.523\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"As a basic study of the degradation analysis of celluloid, TG measurement and FT-IR measurement by the ATR method were performed on a celluloid sheet irradiated with a xenon lamp and ultraviolet rays, and the results were compared with the cellulose acetate sheet. Celluloid showed a decrease in the thermal decomposition start temperature, and cellulose acetate showed an increase. Information on the deterioration of the sample surface was obtained from the pyrolysis start temperature and the IR spectrum of the surface, and information on the deterioration inside the sample was obtained from the peak temperature of DTG. The results were applied to the actual sample saved. Each celluloid sample was degraded by light, and the degree of degradation was considered to be similar to the change when a 0.2 mm thick sheet was irradiated with a xenon lamp for 8 hours. By devising the measurement conditions, it was confirmed that TG/DTA measurement and celluloid sample are effective measurement methods.\",\"PeriodicalId\":9521,\"journal\":{\"name\":\"Bunseki Kagaku\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2022-09-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bunseki Kagaku\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.2116/bunsekikagaku.71.523\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bunseki Kagaku","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.2116/bunsekikagaku.71.523","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

作为纤维素降解分析的基础研究,在用氙灯和紫外线照射的纤维素片上进行了通过ATR法的TG测量和FT-IR测量,并将结果与乙酸纤维素片进行了比较。在热分解开始温度下,类纤维素表现出降低,乙酸纤维素表现出增加。从热解开始温度和表面的IR光谱获得关于样品表面的劣化的信息,并且从DTG的峰值温度获得关于样品内部的劣化信息。将结果应用于保存的实际样本。每个赛璐珞样品被光降解,并且降解程度被认为与当用氙灯照射0.2mm厚的片材8小时时的变化相似。通过设计测量条件,证实TG/DTA测量和赛璐珞样品是有效的测量方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Degradation Analysis of Celluloid
As a basic study of the degradation analysis of celluloid, TG measurement and FT-IR measurement by the ATR method were performed on a celluloid sheet irradiated with a xenon lamp and ultraviolet rays, and the results were compared with the cellulose acetate sheet. Celluloid showed a decrease in the thermal decomposition start temperature, and cellulose acetate showed an increase. Information on the deterioration of the sample surface was obtained from the pyrolysis start temperature and the IR spectrum of the surface, and information on the deterioration inside the sample was obtained from the peak temperature of DTG. The results were applied to the actual sample saved. Each celluloid sample was degraded by light, and the degree of degradation was considered to be similar to the change when a 0.2 mm thick sheet was irradiated with a xenon lamp for 8 hours. By devising the measurement conditions, it was confirmed that TG/DTA measurement and celluloid sample are effective measurement methods.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Bunseki Kagaku
Bunseki Kagaku 化学-分析化学
CiteScore
0.30
自引率
0.00%
发文量
64
审稿时长
3 months
期刊介绍: Bunsekikagaku is a journal written in Japanese and is published monthly by The Japan Society for Analytical Chemistry. The journal publishes papers on all aspects of the theory and practice of analytical sciences, including fundamental and applied, inorganic and organic, wet chemical and instrumental methods.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信