{"title":"Kalibrator Infant Warmer Berbasis Arduino Uno Dilengkapi dengan Penyimpanan Data","authors":"Bayu Wahyudi, D. Ningtias, Ardian Widyastuti","doi":"10.26623/elektrika.v15i1.5780","DOIUrl":null,"url":null,"abstract":"Calibration is an activity to determine the conventional correctness of the designation value of measuring instruments and measuring materials by comparing them with traceable measuring standards to national standards for units of measure and/or international ones. One example of a tool used for calibration is the Infant Warmer Calibrator. The purpose of this research is to produce a tool that can be used to calibrate and analyze temperature and humidity data on infrant warmers. This tool uses five LM35 type temperature sensors with Arduino as the main controller for this tool, and is also equipped with a DHT11 type humidity sensor, and is also equipped with an SD Card as storage. From the results of the study, different results were obtained with the largest error difference of 1.85% at a test point of 35°C and the smallest error presentation was 1.3% at a test point of 34°C and the tool was functioning properly. Keywords: Kalibrator Infant Warmer, Temperature sensor, Humidity Sensor, SD Card. ABSTRAKKalibrasi adalah kegiatan untuk menentukan kebenaran konvensional nilai penunjukkan alat ukur dan bahan ukur dengan cara membandingkan terhadap standar ukur yang mampu telusur (traceable) ke standar nasional untuk satuan ukuran dan/atau internasional. Salah satu contoh alat yang digunakan untuk kalibrasi adalah Kalibrator Infant Warmer. Tujuan penelitian ini adalah untuk menghasilkan alat yang dapat digunakan untuk melakukan kalibrasi serta melakukan analisis data suhu dan kelembapan pada infrant warmer. Alat ini menggunakan lima sensor suhu type LM35 dengan arduino sebagai pengotrol utama pada alat ini, dan juga dilengkapi dengan sensor kelembapan type DHT11, dan juga dilengkapi dengan SD Card sebagai penyimpanan. Dari hasil penelitian didapatkan hasil yang berbeda-beda dengan selisih kesalahan terbesar 1,85 % pada test point 35°C dan presentasi kesalahan terkecil yaitu 1,3% pada test point 34°C dan alat sudah berfungsi dengan baik.","PeriodicalId":31998,"journal":{"name":"Elektrika","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-05-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Elektrika","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26623/elektrika.v15i1.5780","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

校准是一种通过将测量仪器和测量材料与可追溯的测量标准与国家计量单位标准和/或国际标准进行比较来确定其指定值的常规正确性的活动。用于校准的工具的一个例子是婴儿保暖器校准器。本研究的目的是开发一种可用于校准和分析红外线加热器温度和湿度数据的工具。该工具使用五个LM35型温度传感器,Arduino作为该工具的主控制器,还配备了一个DHT11型湿度传感器,并配备了一张SD卡作为存储。从研究结果来看,获得了不同的结果,在35°C的测试点上最大误差差异为1.85%,在34°C的试验点上最小误差为1.3%,工具运行正常。关键词:Kalibrator婴儿保温器,温度传感器,湿度传感器,SD卡。[UNK]ABSTRACCalibration是一项通过将可追溯标准与尺寸单位和/或国际单位的国家标准进行比较来确定测量仪器和材料显示价值的传统事实的活动。用于校准的工具的一个例子是婴儿保暖器校准器。本研究的目的是生产可用于校准和分析红外取暖器温度和湿度数据的工具。该工具在该设备上使用了五个以arduino为主的LM35温度传感器,还配备了DHT11型湿度传感器,并配备了SD卡作为存储。从研究结果来看,获得了不同的结果,在35°C测试点的最大误差序列为1.85%,在34°C测试点将最小误差呈现为1.3%,该装置工作良好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Kalibrator Infant Warmer Berbasis Arduino Uno Dilengkapi dengan Penyimpanan Data
Calibration is an activity to determine the conventional correctness of the designation value of measuring instruments and measuring materials by comparing them with traceable measuring standards to national standards for units of measure and/or international ones. One example of a tool used for calibration is the Infant Warmer Calibrator. The purpose of this research is to produce a tool that can be used to calibrate and analyze temperature and humidity data on infrant warmers. This tool uses five LM35 type temperature sensors with Arduino as the main controller for this tool, and is also equipped with a DHT11 type humidity sensor, and is also equipped with an SD Card as storage. From the results of the study, different results were obtained with the largest error difference of 1.85% at a test point of 35°C and the smallest error presentation was 1.3% at a test point of 34°C and the tool was functioning properly. Keywords: Kalibrator Infant Warmer, Temperature sensor, Humidity Sensor, SD Card. ABSTRAKKalibrasi adalah kegiatan untuk menentukan kebenaran konvensional nilai penunjukkan alat ukur dan bahan ukur dengan cara membandingkan terhadap standar ukur yang mampu telusur (traceable) ke standar nasional untuk satuan ukuran dan/atau internasional. Salah satu contoh alat yang digunakan untuk kalibrasi adalah Kalibrator Infant Warmer. Tujuan penelitian ini adalah untuk menghasilkan alat yang dapat digunakan untuk melakukan kalibrasi serta melakukan analisis data suhu dan kelembapan pada infrant warmer. Alat ini menggunakan lima sensor suhu type LM35 dengan arduino sebagai pengotrol utama pada alat ini, dan juga dilengkapi dengan sensor kelembapan type DHT11, dan juga dilengkapi dengan SD Card sebagai penyimpanan. Dari hasil penelitian didapatkan hasil yang berbeda-beda dengan selisih kesalahan terbesar 1,85 % pada test point 35°C dan presentasi kesalahan terkecil yaitu 1,3% pada test point 34°C dan alat sudah berfungsi dengan baik.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
12
审稿时长
24 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信