G. Sajjan, K. Prasad Naik, K. Varma, Sai Durga Indukuri, Atchyut Gajja, B. Sindhuja
{"title":"毛细管凝聚技术和混合技术对模拟内吸收腔牙齿充填质量的体外评价:锥形束计算机断层扫描研究","authors":"G. Sajjan, K. Prasad Naik, K. Varma, Sai Durga Indukuri, Atchyut Gajja, B. Sindhuja","doi":"10.4103/endo.endo_79_22","DOIUrl":null,"url":null,"abstract":"Aim: The quality of obturation with recent capillary condensation technique and hybrid technique in teeth with artificial internal resorption cavity needs to be evaluated. Methods: Calculation of sample size was done with G*Power software (version 3.1.9.4) (effect size d = 1.46). Eighteen single-canal mandibular premolars were decoronated at the cementoenamel junction for standardization of specimen length as 12 mm. Biomechanical preparation was done with ProTaper Universal rotary file up to F4. Internal resorption cavity was prepared with #08 size round bur 6 mm from the apex. Samples were distributed randomly into two groups. Group I: teeth with bioceramic sealer (EndoSequence BC Sealer, Brasseler, USA) application using conventional technique and hybrid technique of obturation. Group II: capillary condensation technique of bioceramic sealer (EndoSequence BC Sealer, Brasseler USA) using single-cone gutta-percha obturation. The voids in three segments of the root canal were measured with cone-beam computed tomography using “OnDemand3D App” software. Data were statistically analyzed by one-way analysis of variance (ANOVA) and multiple comparisons of Tukey honestly significant difference tests with P < 0.05. Results: The mean area of the void was 0.3963 ± 0.3299 mm2 for Group I and 0.4022 ± 0.4101 mm2 for Group II. There was a difference in the number of voids present in different sections of the root within a group with significance but not between the groups. Conclusion: Capillary condensation technique with single-cone obturation is comparable to conventional sealer application and hybrid technique of obturation for filling internal resorption cavity.","PeriodicalId":11607,"journal":{"name":"Endodontology","volume":"35 1","pages":"24 - 29"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"In vitro evaluation of the quality of obturation with capillary condensation technique and hybrid technique in teeth with simulated internal resorption cavity: A cone-beam computed tomography study\",\"authors\":\"G. Sajjan, K. Prasad Naik, K. Varma, Sai Durga Indukuri, Atchyut Gajja, B. Sindhuja\",\"doi\":\"10.4103/endo.endo_79_22\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Aim: The quality of obturation with recent capillary condensation technique and hybrid technique in teeth with artificial internal resorption cavity needs to be evaluated. Methods: Calculation of sample size was done with G*Power software (version 3.1.9.4) (effect size d = 1.46). Eighteen single-canal mandibular premolars were decoronated at the cementoenamel junction for standardization of specimen length as 12 mm. Biomechanical preparation was done with ProTaper Universal rotary file up to F4. Internal resorption cavity was prepared with #08 size round bur 6 mm from the apex. Samples were distributed randomly into two groups. Group I: teeth with bioceramic sealer (EndoSequence BC Sealer, Brasseler, USA) application using conventional technique and hybrid technique of obturation. Group II: capillary condensation technique of bioceramic sealer (EndoSequence BC Sealer, Brasseler USA) using single-cone gutta-percha obturation. The voids in three segments of the root canal were measured with cone-beam computed tomography using “OnDemand3D App” software. Data were statistically analyzed by one-way analysis of variance (ANOVA) and multiple comparisons of Tukey honestly significant difference tests with P < 0.05. Results: The mean area of the void was 0.3963 ± 0.3299 mm2 for Group I and 0.4022 ± 0.4101 mm2 for Group II. There was a difference in the number of voids present in different sections of the root within a group with significance but not between the groups. Conclusion: Capillary condensation technique with single-cone obturation is comparable to conventional sealer application and hybrid technique of obturation for filling internal resorption cavity.\",\"PeriodicalId\":11607,\"journal\":{\"name\":\"Endodontology\",\"volume\":\"35 1\",\"pages\":\"24 - 29\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Endodontology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/endo.endo_79_22\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Endodontology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/endo.endo_79_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0
摘要
目的:对近期应用毛细管冷凝技术和混合技术充填人工内吸收腔的牙齿的质量进行评价。方法:使用G*Power软件(3.1.9.4版)计算样本量(效果尺寸d=1.46)。18颗下颌前磨牙在牙骨质层连接处进行去骨处理,将样本长度标准化为12mm。使用ProTaper万能旋转锉进行生物力学准备,直至F4。内部吸收腔是用#08尺寸的圆形钻从顶端6mm处制备的。将样本随机分为两组。第一组:使用生物陶瓷密封剂(EndoSequence BC sealer,Brasseler,USA)的牙齿,使用传统技术和混合充填技术。第二组:生物陶瓷密封剂(EndoSequence BC sealer,Brasseler USA)的毛细管冷凝技术,使用单锥牙胶封闭。使用“OnDemand3DApp”软件通过锥形束计算机断层扫描测量根管三段的空隙。通过单因素方差分析(ANOVA)和Tukey诚实显著性差异检验的多重比较对数据进行统计学分析,P<0.05。结果:第一组的平均空隙面积为0.3963±0.3299 mm2,第二组为0.4022±0.4101 mm2。在一组内,根的不同部分存在的空隙数量存在差异,具有显著性,但在各组之间没有差异。结论:单锥封闭的毛细管冷凝技术可与传统封闭器和混合封闭技术相媲美。
In vitro evaluation of the quality of obturation with capillary condensation technique and hybrid technique in teeth with simulated internal resorption cavity: A cone-beam computed tomography study
Aim: The quality of obturation with recent capillary condensation technique and hybrid technique in teeth with artificial internal resorption cavity needs to be evaluated. Methods: Calculation of sample size was done with G*Power software (version 3.1.9.4) (effect size d = 1.46). Eighteen single-canal mandibular premolars were decoronated at the cementoenamel junction for standardization of specimen length as 12 mm. Biomechanical preparation was done with ProTaper Universal rotary file up to F4. Internal resorption cavity was prepared with #08 size round bur 6 mm from the apex. Samples were distributed randomly into two groups. Group I: teeth with bioceramic sealer (EndoSequence BC Sealer, Brasseler, USA) application using conventional technique and hybrid technique of obturation. Group II: capillary condensation technique of bioceramic sealer (EndoSequence BC Sealer, Brasseler USA) using single-cone gutta-percha obturation. The voids in three segments of the root canal were measured with cone-beam computed tomography using “OnDemand3D App” software. Data were statistically analyzed by one-way analysis of variance (ANOVA) and multiple comparisons of Tukey honestly significant difference tests with P < 0.05. Results: The mean area of the void was 0.3963 ± 0.3299 mm2 for Group I and 0.4022 ± 0.4101 mm2 for Group II. There was a difference in the number of voids present in different sections of the root within a group with significance but not between the groups. Conclusion: Capillary condensation technique with single-cone obturation is comparable to conventional sealer application and hybrid technique of obturation for filling internal resorption cavity.