1/3比例缩小的两层钢筋混凝土校舍模型的快速损伤评估

IF 3 Q2 ENGINEERING, CIVIL
S. Chu, Chan-Jung Kang, Mingqing Hu, Liang-Chieh Chang
{"title":"1/3比例缩小的两层钢筋混凝土校舍模型的快速损伤评估","authors":"S. Chu, Chan-Jung Kang, Mingqing Hu, Liang-Chieh Chang","doi":"10.1080/24705314.2021.2019178","DOIUrl":null,"url":null,"abstract":"ABSTRACT This study presents a damage assessment scheme for seismically excited torsion-coupled nonlinear buildings based on the normalized relative displacement vibration shape (NRDVS). In order to investigate the applicability of the proposed NRDVS, the relative displacements are obtained from a real-time structural response integrator (RTSRI) by integrating the relative accelerations simulated from multiple-degree-of-freedom nonlinear models. As a result, the normalized inter-story drift ratio (NIDR) calculated by differencing the normalized displacements of the two successive floors of NRDVS and dividing by the story height can reveal the damaged floors as well as the location of damaged building members. Furthermore, the proposed damage assessment scheme is validated by observing the experimental measurements of shaking table tests of three 1/3 scaled-down two-story reinforced concrete school building models conducted at the National Center for Research on Earthquake Engineering (NCREE), Taipei, Taiwan.","PeriodicalId":43844,"journal":{"name":"Journal of Structural Integrity and Maintenance","volume":null,"pages":null},"PeriodicalIF":3.0000,"publicationDate":"2022-03-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Rapid damage assessment of 1/3 scaled-down two-story reinforced concrete school building models\",\"authors\":\"S. Chu, Chan-Jung Kang, Mingqing Hu, Liang-Chieh Chang\",\"doi\":\"10.1080/24705314.2021.2019178\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABSTRACT This study presents a damage assessment scheme for seismically excited torsion-coupled nonlinear buildings based on the normalized relative displacement vibration shape (NRDVS). In order to investigate the applicability of the proposed NRDVS, the relative displacements are obtained from a real-time structural response integrator (RTSRI) by integrating the relative accelerations simulated from multiple-degree-of-freedom nonlinear models. As a result, the normalized inter-story drift ratio (NIDR) calculated by differencing the normalized displacements of the two successive floors of NRDVS and dividing by the story height can reveal the damaged floors as well as the location of damaged building members. Furthermore, the proposed damage assessment scheme is validated by observing the experimental measurements of shaking table tests of three 1/3 scaled-down two-story reinforced concrete school building models conducted at the National Center for Research on Earthquake Engineering (NCREE), Taipei, Taiwan.\",\"PeriodicalId\":43844,\"journal\":{\"name\":\"Journal of Structural Integrity and Maintenance\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2022-03-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Structural Integrity and Maintenance\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/24705314.2021.2019178\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, CIVIL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Structural Integrity and Maintenance","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/24705314.2021.2019178","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 4

摘要

提出了一种基于归一化相对位移振动形态(NRDVS)的地震激励扭耦合非线性建筑损伤评估方案。为了验证NRDVS的适用性,利用实时结构响应积分器(RTSRI)对多自由度非线性模型模拟的相对加速度进行积分,得到了相对位移。因此,将NRDVS连续两层的归一化位移差值除以层高,计算出归一化层间位移比(NIDR),可以显示受损楼层以及受损建筑构件的位置。此外,通过在台北国家地震工程研究中心(NCREE)进行的3个1/3缩小的两层钢筋混凝土校舍模型的振动台试验测量,验证了所提出的损伤评估方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Rapid damage assessment of 1/3 scaled-down two-story reinforced concrete school building models
ABSTRACT This study presents a damage assessment scheme for seismically excited torsion-coupled nonlinear buildings based on the normalized relative displacement vibration shape (NRDVS). In order to investigate the applicability of the proposed NRDVS, the relative displacements are obtained from a real-time structural response integrator (RTSRI) by integrating the relative accelerations simulated from multiple-degree-of-freedom nonlinear models. As a result, the normalized inter-story drift ratio (NIDR) calculated by differencing the normalized displacements of the two successive floors of NRDVS and dividing by the story height can reveal the damaged floors as well as the location of damaged building members. Furthermore, the proposed damage assessment scheme is validated by observing the experimental measurements of shaking table tests of three 1/3 scaled-down two-story reinforced concrete school building models conducted at the National Center for Research on Earthquake Engineering (NCREE), Taipei, Taiwan.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.90
自引率
9.50%
发文量
24
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信