Aveen K. Mohammed, A. Khaleel, Nawzad N. Ahmed
{"title":"枸橼酸西地那非药物新型涂层碳电极的构建","authors":"Aveen K. Mohammed, A. Khaleel, Nawzad N. Ahmed","doi":"10.32894/kujss.2020.15.2.1","DOIUrl":null,"url":null,"abstract":"In this research, new coated carbon electrodes were constructed and used for the determination of Sildenafil citrate (SILC) drug. The electrodes were constructed by preparing ion-pair for (SILC) with phosphotungstic acid (PTA) or phosphomolybdic (PMA) acid using dibutyl phthalate (DBP) as a plasticizer. These electrodes showed good sensitivity towards SILC with linear range of (1.010 -7 -1.010 -2 ) M, correlation coefficient, (0.9990), the life time (120) days, optimum temperature range (23-65) o C and optimum pH range (2-5) for both electrodes, limit of detection (5.05510 -8 and 5.11610 -8 ) M, slope (57.29 and 59.10) mV/decadefor SILC-PTA and SILC-PMA electrodes respectively. These electrodes were successfully applied for determination of SILC in pure and pharmaceutical preparation form(tablets) with recovery of not less than 98%.","PeriodicalId":34247,"journal":{"name":"mjl@ jm`@ krkwk ldrst l`lmy@","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Construction of New Coated Carbon Electrodes for Determination of Sildenafil Citrate Drug\",\"authors\":\"Aveen K. Mohammed, A. Khaleel, Nawzad N. Ahmed\",\"doi\":\"10.32894/kujss.2020.15.2.1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this research, new coated carbon electrodes were constructed and used for the determination of Sildenafil citrate (SILC) drug. The electrodes were constructed by preparing ion-pair for (SILC) with phosphotungstic acid (PTA) or phosphomolybdic (PMA) acid using dibutyl phthalate (DBP) as a plasticizer. These electrodes showed good sensitivity towards SILC with linear range of (1.010 -7 -1.010 -2 ) M, correlation coefficient, (0.9990), the life time (120) days, optimum temperature range (23-65) o C and optimum pH range (2-5) for both electrodes, limit of detection (5.05510 -8 and 5.11610 -8 ) M, slope (57.29 and 59.10) mV/decadefor SILC-PTA and SILC-PMA electrodes respectively. These electrodes were successfully applied for determination of SILC in pure and pharmaceutical preparation form(tablets) with recovery of not less than 98%.\",\"PeriodicalId\":34247,\"journal\":{\"name\":\"mjl@ jm`@ krkwk ldrst l`lmy@\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"mjl@ jm`@ krkwk ldrst l`lmy@\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.32894/kujss.2020.15.2.1\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"mjl@ jm`@ krkwk ldrst l`lmy@","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32894/kujss.2020.15.2.1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

在本研究中,构建了新的涂层碳电极,并用于枸橼酸西地那非(SILC)药物的测定。以邻苯二甲酸二丁酯(DBP)为增塑剂,用磷钨酸(PTA)或磷钼酸(PMA)制备了(SILC)离子对。这些电极对SILC表现出良好的敏感性,线性范围为(1.010-7-1.010-2)M,相关系数(0.9990),使用寿命(120)天,两种电极的最佳温度范围(23-65)℃和最佳pH范围(2-5),检测限(5.05510-8和5.116斜率分别为(57.29和59.10)mV/decade。这些电极成功地用于测定纯和药物制剂(片剂)中的SILC,回收率不低于98%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Construction of New Coated Carbon Electrodes for Determination of Sildenafil Citrate Drug
In this research, new coated carbon electrodes were constructed and used for the determination of Sildenafil citrate (SILC) drug. The electrodes were constructed by preparing ion-pair for (SILC) with phosphotungstic acid (PTA) or phosphomolybdic (PMA) acid using dibutyl phthalate (DBP) as a plasticizer. These electrodes showed good sensitivity towards SILC with linear range of (1.010 -7 -1.010 -2 ) M, correlation coefficient, (0.9990), the life time (120) days, optimum temperature range (23-65) o C and optimum pH range (2-5) for both electrodes, limit of detection (5.05510 -8 and 5.11610 -8 ) M, slope (57.29 and 59.10) mV/decadefor SILC-PTA and SILC-PMA electrodes respectively. These electrodes were successfully applied for determination of SILC in pure and pharmaceutical preparation form(tablets) with recovery of not less than 98%.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
3
审稿时长
10 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信