{"title":"我有几吨现金,这意味着我们要举行加冕典礼。","authors":"Zahra Amalia, Taufiq Saidi, T. B. Aulia, Mahlil Mahlil","doi":"10.29103/tj.v11i2.507","DOIUrl":null,"url":null,"abstract":"<p align=\"center\"><strong>Abstrak</strong></p><p class=\"11daftarpustaka\"> </p><p>Korosi pada struktur beton betulang dapat mengurangi kinerja struktur dan umur layannya karena volume tulangan yang berkurang. Besarnya jumlah korosi yang dipengaruhi oleh laju korosi dapat digambarkan melalui besarnya densitas arus yang terjadi. Jumlah korosi yang terjadi mempengaruhi perilaku retak pada beton bertulang, oleh karen itu, pada studi ini dilakukan uji eksperimental untuk mengevaluasi pengaruh densitas arus terhadap perilaku retak permukaan beton dari struktur beton bertulang yang mengalami korosi tulangan. Pengujian dilakukan dengan mengaplikasikan variasi densitas arus yaitu 900 µA/cm<sup>2</sup>, 500 µA/cm<sup>2</sup>, 200 µA/cm<sup>2</sup> and 100 µA/cm<sup>2</sup> pada pengujian korosi secara elektrik menggunakan larutan NaCl sebagai elektrolit untuk menghasilkan ion Cl<sup>-</sup>. Benda uji yang digunakan adalah balok dengan luas penampang 150x150 mm<sup>2</sup> dan panjang benda uji 300 mm. Tulangan baja diameter 19 mm digunakan pada tengah penampang. Hasil pengujian menunjukkan bahwa perilaku retak dari beton bertulang yang mengalami korosi pada tulangannya memiliki kurva yang bilinear. Selain itu, hasil pengujian menunjukkan bahwa densitas arus yang rendah memiliki kecepatan retak permukaan beton yang lebih tinggi jika dibandingkan dengan benda uji dengan menggunakan densitas arus yang tinggi.</p><p> </p><p>Kata kunci<em>: korosi, beton bertulang, produk korosi, retak, densitas arus</em></p><p align=\"center\"><strong> </strong></p><p align=\"center\"><strong>Abstract</strong></p><p class=\"Abstract\"> </p><p>Corrosion in reinforced concrete structure can reduce structure performance and its service life due to rebar mass loss. Corrosion amount influenced by corrosion rate can be figured out by using current density. Corrosion amount influences the crack behavior of reinforced concrete, therefore, in this study, experimental study was performed to evaluate the effect of current density to surface concrete cracking behavior of corroded reinforced concrete structure. Accelerated corrosion test tests were conducted with various current density. It was 900 µA/cm2, 500 µA/cm2, 200 µA/cm2 and 100 µA/cm2. NaCl solution was used as electrolyte to produce ion Cl<sup>-</sup>. The specimens were beam with cross section area 150x150 mm<sup>2</sup> and 300 mm in length. Rebar with diameter 19 mm was applied in the center of specimen. The results showed that cracking behavior of corroded rebar has bilinear curve that shows the effect of corrosion products movement through cracks. Furthermore, lower corrosion rate has higher cracking speed than higher corrosion rate.</p><p> </p><p>Keywords: <em>corrosion, reinforced concrete, corrosion products, cracking, current density</em></p>","PeriodicalId":52898,"journal":{"name":"Teras Jurnal Jurnal Teknik Sipil","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"PENGARUH DENSITAS ARUS TERHADAP PERILAKU RETAK BETON BERTULANG YANG MENGALAMI KOROSI TULANGAN\",\"authors\":\"Zahra Amalia, Taufiq Saidi, T. B. Aulia, Mahlil Mahlil\",\"doi\":\"10.29103/tj.v11i2.507\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p align=\\\"center\\\"><strong>Abstrak</strong></p><p class=\\\"11daftarpustaka\\\"> </p><p>Korosi pada struktur beton betulang dapat mengurangi kinerja struktur dan umur layannya karena volume tulangan yang berkurang. Besarnya jumlah korosi yang dipengaruhi oleh laju korosi dapat digambarkan melalui besarnya densitas arus yang terjadi. Jumlah korosi yang terjadi mempengaruhi perilaku retak pada beton bertulang, oleh karen itu, pada studi ini dilakukan uji eksperimental untuk mengevaluasi pengaruh densitas arus terhadap perilaku retak permukaan beton dari struktur beton bertulang yang mengalami korosi tulangan. Pengujian dilakukan dengan mengaplikasikan variasi densitas arus yaitu 900 µA/cm<sup>2</sup>, 500 µA/cm<sup>2</sup>, 200 µA/cm<sup>2</sup> and 100 µA/cm<sup>2</sup> pada pengujian korosi secara elektrik menggunakan larutan NaCl sebagai elektrolit untuk menghasilkan ion Cl<sup>-</sup>. Benda uji yang digunakan adalah balok dengan luas penampang 150x150 mm<sup>2</sup> dan panjang benda uji 300 mm. Tulangan baja diameter 19 mm digunakan pada tengah penampang. Hasil pengujian menunjukkan bahwa perilaku retak dari beton bertulang yang mengalami korosi pada tulangannya memiliki kurva yang bilinear. Selain itu, hasil pengujian menunjukkan bahwa densitas arus yang rendah memiliki kecepatan retak permukaan beton yang lebih tinggi jika dibandingkan dengan benda uji dengan menggunakan densitas arus yang tinggi.</p><p> </p><p>Kata kunci<em>: korosi, beton bertulang, produk korosi, retak, densitas arus</em></p><p align=\\\"center\\\"><strong> </strong></p><p align=\\\"center\\\"><strong>Abstract</strong></p><p class=\\\"Abstract\\\"> </p><p>Corrosion in reinforced concrete structure can reduce structure performance and its service life due to rebar mass loss. Corrosion amount influenced by corrosion rate can be figured out by using current density. Corrosion amount influences the crack behavior of reinforced concrete, therefore, in this study, experimental study was performed to evaluate the effect of current density to surface concrete cracking behavior of corroded reinforced concrete structure. Accelerated corrosion test tests were conducted with various current density. It was 900 µA/cm2, 500 µA/cm2, 200 µA/cm2 and 100 µA/cm2. NaCl solution was used as electrolyte to produce ion Cl<sup>-</sup>. The specimens were beam with cross section area 150x150 mm<sup>2</sup> and 300 mm in length. Rebar with diameter 19 mm was applied in the center of specimen. The results showed that cracking behavior of corroded rebar has bilinear curve that shows the effect of corrosion products movement through cracks. Furthermore, lower corrosion rate has higher cracking speed than higher corrosion rate.</p><p> </p><p>Keywords: <em>corrosion, reinforced concrete, corrosion products, cracking, current density</em></p>\",\"PeriodicalId\":52898,\"journal\":{\"name\":\"Teras Jurnal Jurnal Teknik Sipil\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Teras Jurnal Jurnal Teknik Sipil\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.29103/tj.v11i2.507\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Teras Jurnal Jurnal Teknik Sipil","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29103/tj.v11i2.507","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

摘要受腐蚀速率影响的腐蚀量可以通过电流密度的大小来描述。发生的腐蚀量会影响重复混凝土上的裂缝行为,因此,在本研究中,进行了一项实验测试,以评估电流密度对重复混凝土结构表面上发生骨腐蚀的裂缝行为的影响。通过在使用NaCl溶液作为电解质的电腐蚀试验中应用900µA/cm2、500µA/cm2,200µA/cm2和100µA/cm2的电流密度变化来进行试验,以产生Cl-。使用的测试对象是一个阳台,其孔径宽度为150x150 mm2,测试对象长度为300 mm。孔径中心使用直径为19 mm的钢骨。试验结果表明,重复混凝土在其骨骼上发生腐蚀后,其断裂行为具有双线性曲线。此外,测试结果表明,与使用高电流密度的测试对象相比,低电流密度具有更高的混凝土表面断裂率。关键词:腐蚀、反混凝土、产品腐蚀、裂缝、密度电流[UNK]摘要[UNK]钢筋混凝土结构中的腐蚀会因钢筋质量损失而降低结构性能和使用寿命。利用电流密度可以计算出腐蚀速率对腐蚀量的影响。腐蚀量影响钢筋混凝土的开裂行为,因此,在本研究中,进行了实验研究,以评估电流密度对腐蚀钢筋混凝土结构表面混凝土开裂行为的影响。在不同的电流密度下进行了加速腐蚀试验。其为900µA/cm2、500µA/cm2,200µA/cm2和100µA/cm2。以氯化钠溶液为电解质,生成离子Cl-。试样为横截面积为150x150mm2、长度为300mm的梁。将直径为19 mm的钢筋应用于试样的中心。结果表明,锈蚀钢筋的开裂行为具有双线性曲线,反映了锈蚀产物在裂缝中运动的影响。此外,较低的腐蚀速率比较高的腐蚀速率具有更高的开裂速度。关键词:腐蚀,钢筋混凝土,腐蚀产物,开裂,电流密度
本文章由计算机程序翻译,如有差异,请以英文原文为准。
PENGARUH DENSITAS ARUS TERHADAP PERILAKU RETAK BETON BERTULANG YANG MENGALAMI KOROSI TULANGAN

Abstrak

 

Korosi pada struktur beton betulang dapat mengurangi kinerja struktur dan umur layannya karena volume tulangan yang berkurang. Besarnya jumlah korosi yang dipengaruhi oleh laju korosi dapat digambarkan melalui besarnya densitas arus yang terjadi. Jumlah korosi yang terjadi mempengaruhi perilaku retak pada beton bertulang, oleh karen itu, pada studi ini dilakukan uji eksperimental untuk mengevaluasi pengaruh densitas arus terhadap perilaku retak permukaan beton dari struktur beton bertulang yang mengalami korosi tulangan. Pengujian dilakukan dengan mengaplikasikan variasi densitas arus yaitu 900 µA/cm2, 500 µA/cm2, 200 µA/cm2 and 100 µA/cm2 pada pengujian korosi secara elektrik menggunakan larutan NaCl sebagai elektrolit untuk menghasilkan ion Cl-. Benda uji yang digunakan adalah balok dengan luas penampang 150x150 mm2 dan panjang benda uji 300 mm. Tulangan baja diameter 19 mm digunakan pada tengah penampang. Hasil pengujian menunjukkan bahwa perilaku retak dari beton bertulang yang mengalami korosi pada tulangannya memiliki kurva yang bilinear. Selain itu, hasil pengujian menunjukkan bahwa densitas arus yang rendah memiliki kecepatan retak permukaan beton yang lebih tinggi jika dibandingkan dengan benda uji dengan menggunakan densitas arus yang tinggi.

 

Kata kunci: korosi, beton bertulang, produk korosi, retak, densitas arus

 

Abstract

 

Corrosion in reinforced concrete structure can reduce structure performance and its service life due to rebar mass loss. Corrosion amount influenced by corrosion rate can be figured out by using current density. Corrosion amount influences the crack behavior of reinforced concrete, therefore, in this study, experimental study was performed to evaluate the effect of current density to surface concrete cracking behavior of corroded reinforced concrete structure. Accelerated corrosion test tests were conducted with various current density. It was 900 µA/cm2, 500 µA/cm2, 200 µA/cm2 and 100 µA/cm2. NaCl solution was used as electrolyte to produce ion Cl-. The specimens were beam with cross section area 150x150 mm2 and 300 mm in length. Rebar with diameter 19 mm was applied in the center of specimen. The results showed that cracking behavior of corroded rebar has bilinear curve that shows the effect of corrosion products movement through cracks. Furthermore, lower corrosion rate has higher cracking speed than higher corrosion rate.

 

Keywords: corrosion, reinforced concrete, corrosion products, cracking, current density

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
52
审稿时长
6 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信