{"title":"一种新型全息单像深度重建传感器的现场评价","authors":"Simon Hartlieb","doi":"10.1051/jeos/2023017","DOIUrl":null,"url":null,"abstract":"A camera-based single-image sensor is presented, that is able to measure the distance of one or multiple object points (light emitters). The sensor consists of a camera, whose lens is upgraded with a diffractive optical element (DOE). It fulfils two tasks: adding a vortex point spread function (PSF) and replication of the vortex PSFs to a predefined pattern of K spots. Both, shape and rotation of the vortex PSF is sensitive to defocus. The sensor concept is presented and its capabilities evaluated both on axis and off-axis. The achieved standard deviation of the error ranges between 8.5 µm (on-axis) and 3.5 µm (off-axis) within a measurement range of 20 mm. However, as soon as calibration and measurement position no longer match, the accuracy is limited. An analysis of the effects responsible for this are also part of the publication.","PeriodicalId":674,"journal":{"name":"Journal of the European Optical Society-Rapid Publications","volume":" ","pages":""},"PeriodicalIF":1.9000,"publicationDate":"2023-04-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Field evaluation of a novel holographic single-image depth reconstruction sensor\",\"authors\":\"Simon Hartlieb\",\"doi\":\"10.1051/jeos/2023017\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A camera-based single-image sensor is presented, that is able to measure the distance of one or multiple object points (light emitters). The sensor consists of a camera, whose lens is upgraded with a diffractive optical element (DOE). It fulfils two tasks: adding a vortex point spread function (PSF) and replication of the vortex PSFs to a predefined pattern of K spots. Both, shape and rotation of the vortex PSF is sensitive to defocus. The sensor concept is presented and its capabilities evaluated both on axis and off-axis. The achieved standard deviation of the error ranges between 8.5 µm (on-axis) and 3.5 µm (off-axis) within a measurement range of 20 mm. However, as soon as calibration and measurement position no longer match, the accuracy is limited. An analysis of the effects responsible for this are also part of the publication.\",\"PeriodicalId\":674,\"journal\":{\"name\":\"Journal of the European Optical Society-Rapid Publications\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2023-04-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the European Optical Society-Rapid Publications\",\"FirstCategoryId\":\"4\",\"ListUrlMain\":\"https://doi.org/10.1051/jeos/2023017\",\"RegionNum\":4,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"OPTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the European Optical Society-Rapid Publications","FirstCategoryId":"4","ListUrlMain":"https://doi.org/10.1051/jeos/2023017","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPTICS","Score":null,"Total":0}
Field evaluation of a novel holographic single-image depth reconstruction sensor
A camera-based single-image sensor is presented, that is able to measure the distance of one or multiple object points (light emitters). The sensor consists of a camera, whose lens is upgraded with a diffractive optical element (DOE). It fulfils two tasks: adding a vortex point spread function (PSF) and replication of the vortex PSFs to a predefined pattern of K spots. Both, shape and rotation of the vortex PSF is sensitive to defocus. The sensor concept is presented and its capabilities evaluated both on axis and off-axis. The achieved standard deviation of the error ranges between 8.5 µm (on-axis) and 3.5 µm (off-axis) within a measurement range of 20 mm. However, as soon as calibration and measurement position no longer match, the accuracy is limited. An analysis of the effects responsible for this are also part of the publication.
期刊介绍:
Rapid progress in optics and photonics has broadened its application enormously into many branches, including information and communication technology, security, sensing, bio- and medical sciences, healthcare and chemistry.
Recent achievements in other sciences have allowed continual discovery of new natural mysteries and formulation of challenging goals for optics that require further development of modern concepts and running fundamental research.
The Journal of the European Optical Society – Rapid Publications (JEOS:RP) aims to tackle all of the aforementioned points in the form of prompt, scientific, high-quality communications that report on the latest findings. It presents emerging technologies and outlining strategic goals in optics and photonics.
The journal covers both fundamental and applied topics, including but not limited to:
Classical and quantum optics
Light/matter interaction
Optical communication
Micro- and nanooptics
Nonlinear optical phenomena
Optical materials
Optical metrology
Optical spectroscopy
Colour research
Nano and metamaterials
Modern photonics technology
Optical engineering, design and instrumentation
Optical applications in bio-physics and medicine
Interdisciplinary fields using photonics, such as in energy, climate change and cultural heritage
The journal aims to provide readers with recent and important achievements in optics/photonics and, as its name suggests, it strives for the shortest possible publication time.