{"title":"一种新型双路高通量声光可调滤光成像分光偏振计","authors":"R. Abdlaty, Q. Fang","doi":"10.1255/jsi.2020.a20","DOIUrl":null,"url":null,"abstract":"It is highly demanding to identify healthy and non-healthy species in a heterogeneous environment such as human tissues. In such a case, one identifier, such as a spectral fingerprint, might be inadequate. Therefore, additional identification is required, for instance, a polarisation measurement. In view of that, the development of a spectropolarimeter that captures two cross-polarised arrays of spectral images is a key requirement. To meet this requirement, an imager optical setup has been designed to provide spatial, spectral and polarisation preference information for species that exist in a heterogeneous environment, such as in medical tissue samples. The spectral and polarisation information is obtained employing an acousto-optic tunable filter and a polarising beam splitter, respectively. The optical imager is designed to operate in the visible-near infrared range (450–850 nm) with a spectral resolution of 3 nm. The spectropolarimeter design along with optical characterisation results are reported.","PeriodicalId":37385,"journal":{"name":"Journal of Spectral Imaging","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-12-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A novel dual-path high-throughput acousto-optic tunable filter imaging spectropolarimeter\",\"authors\":\"R. Abdlaty, Q. Fang\",\"doi\":\"10.1255/jsi.2020.a20\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"It is highly demanding to identify healthy and non-healthy species in a heterogeneous environment such as human tissues. In such a case, one identifier, such as a spectral fingerprint, might be inadequate. Therefore, additional identification is required, for instance, a polarisation measurement. In view of that, the development of a spectropolarimeter that captures two cross-polarised arrays of spectral images is a key requirement. To meet this requirement, an imager optical setup has been designed to provide spatial, spectral and polarisation preference information for species that exist in a heterogeneous environment, such as in medical tissue samples. The spectral and polarisation information is obtained employing an acousto-optic tunable filter and a polarising beam splitter, respectively. The optical imager is designed to operate in the visible-near infrared range (450–850 nm) with a spectral resolution of 3 nm. The spectropolarimeter design along with optical characterisation results are reported.\",\"PeriodicalId\":37385,\"journal\":{\"name\":\"Journal of Spectral Imaging\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-12-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Spectral Imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1255/jsi.2020.a20\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Chemistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Spectral Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1255/jsi.2020.a20","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Chemistry","Score":null,"Total":0}
A novel dual-path high-throughput acousto-optic tunable filter imaging spectropolarimeter
It is highly demanding to identify healthy and non-healthy species in a heterogeneous environment such as human tissues. In such a case, one identifier, such as a spectral fingerprint, might be inadequate. Therefore, additional identification is required, for instance, a polarisation measurement. In view of that, the development of a spectropolarimeter that captures two cross-polarised arrays of spectral images is a key requirement. To meet this requirement, an imager optical setup has been designed to provide spatial, spectral and polarisation preference information for species that exist in a heterogeneous environment, such as in medical tissue samples. The spectral and polarisation information is obtained employing an acousto-optic tunable filter and a polarising beam splitter, respectively. The optical imager is designed to operate in the visible-near infrared range (450–850 nm) with a spectral resolution of 3 nm. The spectropolarimeter design along with optical characterisation results are reported.
期刊介绍:
JSI—Journal of Spectral Imaging is the first journal to bring together current research from the diverse research areas of spectral, hyperspectral and chemical imaging as well as related areas such as remote sensing, chemometrics, data mining and data handling for spectral image data. We believe all those working in Spectral Imaging can benefit from the knowledge of others even in widely different fields. We welcome original research papers, letters, review articles, tutorial papers, short communications and technical notes.