多层计算机断层扫描评估网状钛植入物在腹股沟疝修补术后的收缩

P. Nikitin, N. Nudnov, I. Znamenskiy, R. Azimov, A. A. Karpova, E. E. Averin
{"title":"多层计算机断层扫描评估网状钛植入物在腹股沟疝修补术后的收缩","authors":"P. Nikitin, N. Nudnov, I. Znamenskiy, R. Azimov, A. A. Karpova, E. E. Averin","doi":"10.20862/0042-4676-2021-102-6-377-382","DOIUrl":null,"url":null,"abstract":"Objective: to assess the percentage of mesh “titanium silk” implant shrinkage after inguinal hernia repair surgery in the late postoperative period using multi-slice computed tomography (MSCT). Material and methods. The comparative assessment of the long-term results of treatment in 90 patients with inguinal hernias was performed using MSCT. In 36 (40%) patients of Group 1 the titanium implant was used in Lichtenstein hernia repair surgery. In Group 2, 54 (60%) patients were operated by laparoscopic hernia repair surgery. On day 3 and 3 months after surgery every patient underwent MSCT with subsequent determination of the implant square. Results. The percent of mesh “titanium silk” implant shrinkage 3 months after surgery according to MSCT was 4.4% in Lichtenstein hernia repair group, and 8.3% in laparoscopic hernia repair group. According to Kruskal-Wallis test, there were no statistic differences of this indicator between two groups (p = 0,185). Conclusion. The analysis of long-term results of inguinal hernia repair surgery with titanium mesh implants using MSCT showed that implant square significantly decreases 3 months after surgery. There were no significant differences in implants shrinkage regarding the type of surgery. MSCT is an effective method for evaluating the size of mesh titanium implants after hernia repair surgery.","PeriodicalId":34090,"journal":{"name":"Vestnik rentgenologii i radiologii","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-02-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Multi-Slice Computed Tomography in Assessing Mesh Titanium Implant Shrinkage After Prosthetic Inguinal Hernioplasty\",\"authors\":\"P. Nikitin, N. Nudnov, I. Znamenskiy, R. Azimov, A. A. Karpova, E. E. Averin\",\"doi\":\"10.20862/0042-4676-2021-102-6-377-382\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective: to assess the percentage of mesh “titanium silk” implant shrinkage after inguinal hernia repair surgery in the late postoperative period using multi-slice computed tomography (MSCT). Material and methods. The comparative assessment of the long-term results of treatment in 90 patients with inguinal hernias was performed using MSCT. In 36 (40%) patients of Group 1 the titanium implant was used in Lichtenstein hernia repair surgery. In Group 2, 54 (60%) patients were operated by laparoscopic hernia repair surgery. On day 3 and 3 months after surgery every patient underwent MSCT with subsequent determination of the implant square. Results. The percent of mesh “titanium silk” implant shrinkage 3 months after surgery according to MSCT was 4.4% in Lichtenstein hernia repair group, and 8.3% in laparoscopic hernia repair group. According to Kruskal-Wallis test, there were no statistic differences of this indicator between two groups (p = 0,185). Conclusion. The analysis of long-term results of inguinal hernia repair surgery with titanium mesh implants using MSCT showed that implant square significantly decreases 3 months after surgery. There were no significant differences in implants shrinkage regarding the type of surgery. MSCT is an effective method for evaluating the size of mesh titanium implants after hernia repair surgery.\",\"PeriodicalId\":34090,\"journal\":{\"name\":\"Vestnik rentgenologii i radiologii\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-02-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Vestnik rentgenologii i radiologii\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.20862/0042-4676-2021-102-6-377-382\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vestnik rentgenologii i radiologii","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.20862/0042-4676-2021-102-6-377-382","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:应用多层螺旋ct (MSCT)评价腹股沟疝修补术后后期补片“钛丝”植入物收缩率。材料和方法。采用MSCT对90例腹股沟疝患者的长期治疗效果进行了比较评估。第一组36例(40%)患者采用钛种植体进行利希滕斯坦疝修补术。第2组54例(60%)患者行腹腔镜疝修补术。术后第3天和第3个月,每位患者都进行了MSCT,随后确定了种植体的面积。结果。MSCT显示,Lichtenstein疝修补组术后3个月补片“钛丝”植入物收缩率为4.4%,腹腔镜疝修补组为8.3%。经Kruskal-Wallis检验,两组间该指标无统计学差异(p = 0.185)。结论。MSCT对腹股沟疝修补手术钛网种植体的远期结果分析显示,术后3个月种植体方明显减少。不同手术类型的种植体收缩无显著差异。MSCT是评价疝修补术后网状钛植入物大小的有效方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Multi-Slice Computed Tomography in Assessing Mesh Titanium Implant Shrinkage After Prosthetic Inguinal Hernioplasty
Objective: to assess the percentage of mesh “titanium silk” implant shrinkage after inguinal hernia repair surgery in the late postoperative period using multi-slice computed tomography (MSCT). Material and methods. The comparative assessment of the long-term results of treatment in 90 patients with inguinal hernias was performed using MSCT. In 36 (40%) patients of Group 1 the titanium implant was used in Lichtenstein hernia repair surgery. In Group 2, 54 (60%) patients were operated by laparoscopic hernia repair surgery. On day 3 and 3 months after surgery every patient underwent MSCT with subsequent determination of the implant square. Results. The percent of mesh “titanium silk” implant shrinkage 3 months after surgery according to MSCT was 4.4% in Lichtenstein hernia repair group, and 8.3% in laparoscopic hernia repair group. According to Kruskal-Wallis test, there were no statistic differences of this indicator between two groups (p = 0,185). Conclusion. The analysis of long-term results of inguinal hernia repair surgery with titanium mesh implants using MSCT showed that implant square significantly decreases 3 months after surgery. There were no significant differences in implants shrinkage regarding the type of surgery. MSCT is an effective method for evaluating the size of mesh titanium implants after hernia repair surgery.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
24
审稿时长
36 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信