{"title":"尼日利亚南南三角洲州阿尼奥查南部地方政府地区石油产品的放射性评估","authors":"B. Ijabor, A. Omojola, F. Omojola, Favour Chukwueke, Praise Azuka, Prudent Agama, Francisca Okafor","doi":"10.4103/rpe.rpe_5_22","DOIUrl":null,"url":null,"abstract":"Monitoring the background levels from petroleum products is essential because of the everyday use and the increasing number of fuel, diesel, kerosene, and gas stations in Delta State, Nigeria. The study aims to determine the background ionizing radiation (BIR) in milli-Roentgen per hour (mR/h), absorbed dose rate (ADR) (nGy/h), and annual effective dose rate (AED) (mSv/year) in selected fuel, diesel, kerosene, and cooking gas-dispensing stations in Aniocha South Local Government Area of Delta State. The study was carried out using a calibrated Geiger Muller detector (Radiation Alert Inspector) in count per minute mode for point measurements and a geographical positioning system for determining the longitude and latitude of each point where measurements were taken from. The mean outdoor BIR, ADR, and AED were 0.011 ± 0.002 mR/h, 91.6 ± 19.5 nGy/h, and 0.11 ± 0.02 mSv/year, respectively, with 84% of the BIR below the world average. The mean BIR was below the world average while the ADR and AED were above it. Kerosene stations had the highest BIR. The outdoor measurements from this study were comparable to similar articles with slight variation. The study shows that the attendant and customers were safe in the areas where this study was conducted.","PeriodicalId":32488,"journal":{"name":"Radiation Protection and Environment","volume":"45 1","pages":"33 - 40"},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Radiological assessment of petroleum products in Aniocha South Local Government Area of Delta State, South-South Nigeria\",\"authors\":\"B. Ijabor, A. Omojola, F. Omojola, Favour Chukwueke, Praise Azuka, Prudent Agama, Francisca Okafor\",\"doi\":\"10.4103/rpe.rpe_5_22\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Monitoring the background levels from petroleum products is essential because of the everyday use and the increasing number of fuel, diesel, kerosene, and gas stations in Delta State, Nigeria. The study aims to determine the background ionizing radiation (BIR) in milli-Roentgen per hour (mR/h), absorbed dose rate (ADR) (nGy/h), and annual effective dose rate (AED) (mSv/year) in selected fuel, diesel, kerosene, and cooking gas-dispensing stations in Aniocha South Local Government Area of Delta State. The study was carried out using a calibrated Geiger Muller detector (Radiation Alert Inspector) in count per minute mode for point measurements and a geographical positioning system for determining the longitude and latitude of each point where measurements were taken from. The mean outdoor BIR, ADR, and AED were 0.011 ± 0.002 mR/h, 91.6 ± 19.5 nGy/h, and 0.11 ± 0.02 mSv/year, respectively, with 84% of the BIR below the world average. The mean BIR was below the world average while the ADR and AED were above it. Kerosene stations had the highest BIR. The outdoor measurements from this study were comparable to similar articles with slight variation. The study shows that the attendant and customers were safe in the areas where this study was conducted.\",\"PeriodicalId\":32488,\"journal\":{\"name\":\"Radiation Protection and Environment\",\"volume\":\"45 1\",\"pages\":\"33 - 40\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiation Protection and Environment\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/rpe.rpe_5_22\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation Protection and Environment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/rpe.rpe_5_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

由于尼日利亚三角洲州的燃料、柴油、煤油和加油站的日常使用和数量不断增加,监测石油产品的本底水平至关重要。本研究旨在确定三角洲州阿尼奥查南部地方政府区选定的燃料、柴油、煤油和烹饪用汽油加气站的本底电离辐射(BIR)(单位为毫伦索每小时(mR/h))、吸收剂量率(ADR) (nGy/h)和年有效剂量率(AED) (mSv/年)。这项研究使用经过校准的盖革穆勒探测器(辐射警报检查员)以每分钟计数模式进行点测量,并使用地理定位系统确定每个测量点的经度和纬度。平均室外BIR、ADR和AED分别为0.011±0.002 mR/h、91.6±19.5 nGy/h和0.11±0.02 mSv/年,其中84%的BIR低于世界平均水平。平均BIR低于世界平均水平,ADR和AED高于世界平均水平。煤油站的BIR最高。本研究的室外测量值与类似的文章具有可比性,差异很小。研究表明,在进行这项研究的地区,服务员和顾客是安全的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Radiological assessment of petroleum products in Aniocha South Local Government Area of Delta State, South-South Nigeria
Monitoring the background levels from petroleum products is essential because of the everyday use and the increasing number of fuel, diesel, kerosene, and gas stations in Delta State, Nigeria. The study aims to determine the background ionizing radiation (BIR) in milli-Roentgen per hour (mR/h), absorbed dose rate (ADR) (nGy/h), and annual effective dose rate (AED) (mSv/year) in selected fuel, diesel, kerosene, and cooking gas-dispensing stations in Aniocha South Local Government Area of Delta State. The study was carried out using a calibrated Geiger Muller detector (Radiation Alert Inspector) in count per minute mode for point measurements and a geographical positioning system for determining the longitude and latitude of each point where measurements were taken from. The mean outdoor BIR, ADR, and AED were 0.011 ± 0.002 mR/h, 91.6 ± 19.5 nGy/h, and 0.11 ± 0.02 mSv/year, respectively, with 84% of the BIR below the world average. The mean BIR was below the world average while the ADR and AED were above it. Kerosene stations had the highest BIR. The outdoor measurements from this study were comparable to similar articles with slight variation. The study shows that the attendant and customers were safe in the areas where this study was conducted.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
15 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信