Anudeep Katrevula, Goutham Reddy Katukuri, A. Singh, P. Inavolu, H. Rughwani, Siddhartha Reddy Alla, M. Ramchandani, N. Duvvur
{"title":"人工智能辅助内吞镜检查使用endobrain的真实世界经验——来自三级保健中心的观察性研究","authors":"Anudeep Katrevula, Goutham Reddy Katukuri, A. Singh, P. Inavolu, H. Rughwani, Siddhartha Reddy Alla, M. Ramchandani, N. Duvvur","doi":"10.1055/s-0042-1758535","DOIUrl":null,"url":null,"abstract":"Abstract Background and Aims Precise optical diagnosis of colorectal polyps could improve the cost-effectiveness of colonoscopy and reduce polypectomy-related complications. We conducted this study to estimate the diagnostic performance of visual inspection alone (WLI + NBI) and of EndoBRAIN (endocytoscopy-computer-aided diagnosis [EC-CAD]) in identifying a lesion as neoplastic or nonneoplastic using EC in real-world scenario. Methods In this observational, prospective, pilot study, a total of 55 polyps were studied in the patients aged more than or equal to 18 years. EndoBRAIN is an artificial intelligence (AI)-based system that analyzes cell nuclei, crypt structure, and vessel pattern in differentiating neoplastic and nonneoplastic lesion in real-time. Endoscopist assessed polyps using white light imaging (WLI), narrow band imaging (NBI) initially followed by assessment using EC with NBI and EC with methylene blue staining. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of endoscopist and EndoBRAIN in identifying the neoplastic from nonneoplastic polyp was compared using histopathology as gold-standard. Results A total of 55 polyps were studied, in which most of them were diminutive (36/55) and located in rectum (21/55). The image acquisition rate was 78% (43/55) and histopathology of the majority was identified to be hyperplastic (20/43) and low-grade adenoma (16/43). EndoBRAIN identified colonic polyps with 100% sensitivity, 81.82% specificity (95% confidence interval [CI], 59.7–94.8%), 90.7% accuracy (95% CI, 77.86–97.41%), 84% positive predictive value (95% CI, 68.4–92.72%), and 100% negative predictive value. The sensitivity and negative predictive value were significantly greater than visual inspection of endoscopist. The diagnostic accuracy seems to be superior; however, it did not reach statistical significance. Specificity and positive predictive value were similar in both groups. Conclusion Optical diagnosis using EC and EC-CAD has a potential role in predicting the histopathological diagnosis. The diagnostic performance of CAD seems to be better than endoscopist using EC for predicting neoplastic lesions.","PeriodicalId":43098,"journal":{"name":"Journal of Digestive Endoscopy","volume":"14 1","pages":"003 - 007"},"PeriodicalIF":0.4000,"publicationDate":"2022-12-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Real-World Experience of AI-Assisted Endocytoscopy Using EndoBRAIN—An Observational Study from a Tertiary Care Center\",\"authors\":\"Anudeep Katrevula, Goutham Reddy Katukuri, A. Singh, P. Inavolu, H. Rughwani, Siddhartha Reddy Alla, M. Ramchandani, N. Duvvur\",\"doi\":\"10.1055/s-0042-1758535\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Background and Aims Precise optical diagnosis of colorectal polyps could improve the cost-effectiveness of colonoscopy and reduce polypectomy-related complications. We conducted this study to estimate the diagnostic performance of visual inspection alone (WLI + NBI) and of EndoBRAIN (endocytoscopy-computer-aided diagnosis [EC-CAD]) in identifying a lesion as neoplastic or nonneoplastic using EC in real-world scenario. Methods In this observational, prospective, pilot study, a total of 55 polyps were studied in the patients aged more than or equal to 18 years. EndoBRAIN is an artificial intelligence (AI)-based system that analyzes cell nuclei, crypt structure, and vessel pattern in differentiating neoplastic and nonneoplastic lesion in real-time. Endoscopist assessed polyps using white light imaging (WLI), narrow band imaging (NBI) initially followed by assessment using EC with NBI and EC with methylene blue staining. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of endoscopist and EndoBRAIN in identifying the neoplastic from nonneoplastic polyp was compared using histopathology as gold-standard. Results A total of 55 polyps were studied, in which most of them were diminutive (36/55) and located in rectum (21/55). The image acquisition rate was 78% (43/55) and histopathology of the majority was identified to be hyperplastic (20/43) and low-grade adenoma (16/43). EndoBRAIN identified colonic polyps with 100% sensitivity, 81.82% specificity (95% confidence interval [CI], 59.7–94.8%), 90.7% accuracy (95% CI, 77.86–97.41%), 84% positive predictive value (95% CI, 68.4–92.72%), and 100% negative predictive value. The sensitivity and negative predictive value were significantly greater than visual inspection of endoscopist. The diagnostic accuracy seems to be superior; however, it did not reach statistical significance. Specificity and positive predictive value were similar in both groups. Conclusion Optical diagnosis using EC and EC-CAD has a potential role in predicting the histopathological diagnosis. The diagnostic performance of CAD seems to be better than endoscopist using EC for predicting neoplastic lesions.\",\"PeriodicalId\":43098,\"journal\":{\"name\":\"Journal of Digestive Endoscopy\",\"volume\":\"14 1\",\"pages\":\"003 - 007\"},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2022-12-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Digestive Endoscopy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1055/s-0042-1758535\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"GASTROENTEROLOGY & HEPATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Digestive Endoscopy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0042-1758535","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
Real-World Experience of AI-Assisted Endocytoscopy Using EndoBRAIN—An Observational Study from a Tertiary Care Center
Abstract Background and Aims Precise optical diagnosis of colorectal polyps could improve the cost-effectiveness of colonoscopy and reduce polypectomy-related complications. We conducted this study to estimate the diagnostic performance of visual inspection alone (WLI + NBI) and of EndoBRAIN (endocytoscopy-computer-aided diagnosis [EC-CAD]) in identifying a lesion as neoplastic or nonneoplastic using EC in real-world scenario. Methods In this observational, prospective, pilot study, a total of 55 polyps were studied in the patients aged more than or equal to 18 years. EndoBRAIN is an artificial intelligence (AI)-based system that analyzes cell nuclei, crypt structure, and vessel pattern in differentiating neoplastic and nonneoplastic lesion in real-time. Endoscopist assessed polyps using white light imaging (WLI), narrow band imaging (NBI) initially followed by assessment using EC with NBI and EC with methylene blue staining. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of endoscopist and EndoBRAIN in identifying the neoplastic from nonneoplastic polyp was compared using histopathology as gold-standard. Results A total of 55 polyps were studied, in which most of them were diminutive (36/55) and located in rectum (21/55). The image acquisition rate was 78% (43/55) and histopathology of the majority was identified to be hyperplastic (20/43) and low-grade adenoma (16/43). EndoBRAIN identified colonic polyps with 100% sensitivity, 81.82% specificity (95% confidence interval [CI], 59.7–94.8%), 90.7% accuracy (95% CI, 77.86–97.41%), 84% positive predictive value (95% CI, 68.4–92.72%), and 100% negative predictive value. The sensitivity and negative predictive value were significantly greater than visual inspection of endoscopist. The diagnostic accuracy seems to be superior; however, it did not reach statistical significance. Specificity and positive predictive value were similar in both groups. Conclusion Optical diagnosis using EC and EC-CAD has a potential role in predicting the histopathological diagnosis. The diagnostic performance of CAD seems to be better than endoscopist using EC for predicting neoplastic lesions.
期刊介绍:
The Journal of Digestive Endoscopy (JDE) is the official publication of the Society of Gastrointestinal Endoscopy of India that has over 1500 members. The society comprises of several key clinicians in this field from different parts of the country and has key international speakers in its advisory board. JDE is a double-blinded peer-reviewed, print and online journal publishing quarterly. It focuses on original investigations, reviews, case reports and clinical images as well as key investigations including but not limited to cholangiopancreatography, fluoroscopy, capsule endoscopy etc.