并网逆变器主导电力系统的小信号建模与稳定性分析

IF 1.9 Q4 ENERGY & FUELS
Yaran Li , Long Fu , Qiang Li , Wei Wang , Yubin Jia , Zhao Yang Dong
{"title":"并网逆变器主导电力系统的小信号建模与稳定性分析","authors":"Yaran Li ,&nbsp;Long Fu ,&nbsp;Qiang Li ,&nbsp;Wei Wang ,&nbsp;Yubin Jia ,&nbsp;Zhao Yang Dong","doi":"10.1016/j.gloei.2023.06.010","DOIUrl":null,"url":null,"abstract":"<div><p>In this paper, the explicit state-space model for a multi-inverter system including grid-following inverter-based generators (IBGs) and grid-forming IBGs is developed by the two-level component connection method (CCM), which modularized inverter control blocks at the primary level and IBGs at the secondary level. Based on the comprehensive state-space model representing full order of system dynamics, eigenvalues of the overall system are thoroughly analyzed, identifying potential adverse impacts of not only grid-following inverters, but also grid forming inverters on the system small- signal stability, with the underlying principle of oscillations also understood. Numerical and simulation results validate effectiveness of the proposed methodology on IEEE benchmarking 39-bus system</p></div>","PeriodicalId":36174,"journal":{"name":"Global Energy Interconnection","volume":"6 3","pages":"Pages 363-374"},"PeriodicalIF":1.9000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Small-signal modelling and stability analysis of grid-following and grid-forming inverters dominated power system\",\"authors\":\"Yaran Li ,&nbsp;Long Fu ,&nbsp;Qiang Li ,&nbsp;Wei Wang ,&nbsp;Yubin Jia ,&nbsp;Zhao Yang Dong\",\"doi\":\"10.1016/j.gloei.2023.06.010\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>In this paper, the explicit state-space model for a multi-inverter system including grid-following inverter-based generators (IBGs) and grid-forming IBGs is developed by the two-level component connection method (CCM), which modularized inverter control blocks at the primary level and IBGs at the secondary level. Based on the comprehensive state-space model representing full order of system dynamics, eigenvalues of the overall system are thoroughly analyzed, identifying potential adverse impacts of not only grid-following inverters, but also grid forming inverters on the system small- signal stability, with the underlying principle of oscillations also understood. Numerical and simulation results validate effectiveness of the proposed methodology on IEEE benchmarking 39-bus system</p></div>\",\"PeriodicalId\":36174,\"journal\":{\"name\":\"Global Energy Interconnection\",\"volume\":\"6 3\",\"pages\":\"Pages 363-374\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2023-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Global Energy Interconnection\",\"FirstCategoryId\":\"1087\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2096511723000531\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Global Energy Interconnection","FirstCategoryId":"1087","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2096511723000531","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 1

摘要

本文采用两级组件连接方法(CCM),将一级逆变器控制模块模块化,二级逆变器控制模块模块化,建立了包括电网跟随逆变器发电机(ibg)和并网发电机组(ibg)在内的多逆变器系统的显式状态空间模型。基于表示系统动力学全阶的综合状态空间模型,深入分析了整个系统的特征值,识别了随网逆变器和成网逆变器对系统小信号稳定性的潜在不利影响,并了解了其振荡的基本原理。数值和仿真结果验证了该方法在IEEE 39总线系统基准测试中的有效性
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Small-signal modelling and stability analysis of grid-following and grid-forming inverters dominated power system

In this paper, the explicit state-space model for a multi-inverter system including grid-following inverter-based generators (IBGs) and grid-forming IBGs is developed by the two-level component connection method (CCM), which modularized inverter control blocks at the primary level and IBGs at the secondary level. Based on the comprehensive state-space model representing full order of system dynamics, eigenvalues of the overall system are thoroughly analyzed, identifying potential adverse impacts of not only grid-following inverters, but also grid forming inverters on the system small- signal stability, with the underlying principle of oscillations also understood. Numerical and simulation results validate effectiveness of the proposed methodology on IEEE benchmarking 39-bus system

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Global Energy Interconnection
Global Energy Interconnection Engineering-Automotive Engineering
CiteScore
5.70
自引率
0.00%
发文量
985
审稿时长
15 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信