Thaiane Rodrigues Aguiar, Wladimir Franco de Sá Barbosa, Marina Di Francescantonio, Marcelo Giannini
{"title":"陶瓷底漆及硅化后热处理对树脂水泥与二硅酸锂基陶瓷粘结强度的影响","authors":"Thaiane Rodrigues Aguiar, Wladimir Franco de Sá Barbosa, Marina Di Francescantonio, Marcelo Giannini","doi":"10.1186/s40563-016-0078-0","DOIUrl":null,"url":null,"abstract":"<p>This study evaluated the effect of different ceramic primers and heat treatment of silane coupling agents on bond strength of resin cement to glass ceramic. Five ceramic primers (Clearfil Ceramic Primer/CCP, MonoBond-S, ProSil, RelyX Ceramic Primer and Silano) and one conventional resin cement (RelyX ARC) were tested. Lithium disilicate-based ceramic plates were previously etched with hydrofluoric acid, except for CCP (n?=?10). All silane agents were applied to ceramics according to the manufacturer’s instructions and primed ceramics plates were heated (in oven at 100?°C for 1?min) or not before resin cement placement. Dual-cure resin cement was mixed and inserted in tubes (0.75?mm diameter?×?1?mm height) that were positioned over primed ceramic surfaces. Micro-shear testing was performed using a universal testing machine. Bond strength data were analyzed using two-way ANOVA and Tukey’s test (5%). Ceramic primer heating did not improve the bond strength of the resin cement to lithium disilicate. Most of ceramic primers did not indicate significant difference in bond strength among them; however, CCP yielded the lowest bond strength among the ceramic primers. In conclusion, when the silane was applied on etched surface the bond strength was higher and heat treatment of silane coupling agents did not affect the bond strength.</p>","PeriodicalId":464,"journal":{"name":"Applied Adhesion Science","volume":"4 1","pages":""},"PeriodicalIF":1.6800,"publicationDate":"2016-12-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1186/s40563-016-0078-0","citationCount":"5","resultStr":"{\"title\":\"Effects of ceramic primers and post-silanization heat treatment on bond strength of resin cement to lithium disilicate-based ceramic\",\"authors\":\"Thaiane Rodrigues Aguiar, Wladimir Franco de Sá Barbosa, Marina Di Francescantonio, Marcelo Giannini\",\"doi\":\"10.1186/s40563-016-0078-0\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>This study evaluated the effect of different ceramic primers and heat treatment of silane coupling agents on bond strength of resin cement to glass ceramic. Five ceramic primers (Clearfil Ceramic Primer/CCP, MonoBond-S, ProSil, RelyX Ceramic Primer and Silano) and one conventional resin cement (RelyX ARC) were tested. Lithium disilicate-based ceramic plates were previously etched with hydrofluoric acid, except for CCP (n?=?10). All silane agents were applied to ceramics according to the manufacturer’s instructions and primed ceramics plates were heated (in oven at 100?°C for 1?min) or not before resin cement placement. Dual-cure resin cement was mixed and inserted in tubes (0.75?mm diameter?×?1?mm height) that were positioned over primed ceramic surfaces. Micro-shear testing was performed using a universal testing machine. Bond strength data were analyzed using two-way ANOVA and Tukey’s test (5%). Ceramic primer heating did not improve the bond strength of the resin cement to lithium disilicate. Most of ceramic primers did not indicate significant difference in bond strength among them; however, CCP yielded the lowest bond strength among the ceramic primers. In conclusion, when the silane was applied on etched surface the bond strength was higher and heat treatment of silane coupling agents did not affect the bond strength.</p>\",\"PeriodicalId\":464,\"journal\":{\"name\":\"Applied Adhesion Science\",\"volume\":\"4 1\",\"pages\":\"\"},\"PeriodicalIF\":1.6800,\"publicationDate\":\"2016-12-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1186/s40563-016-0078-0\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied Adhesion Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://link.springer.com/article/10.1186/s40563-016-0078-0\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Adhesion Science","FirstCategoryId":"1085","ListUrlMain":"https://link.springer.com/article/10.1186/s40563-016-0078-0","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
Effects of ceramic primers and post-silanization heat treatment on bond strength of resin cement to lithium disilicate-based ceramic
This study evaluated the effect of different ceramic primers and heat treatment of silane coupling agents on bond strength of resin cement to glass ceramic. Five ceramic primers (Clearfil Ceramic Primer/CCP, MonoBond-S, ProSil, RelyX Ceramic Primer and Silano) and one conventional resin cement (RelyX ARC) were tested. Lithium disilicate-based ceramic plates were previously etched with hydrofluoric acid, except for CCP (n?=?10). All silane agents were applied to ceramics according to the manufacturer’s instructions and primed ceramics plates were heated (in oven at 100?°C for 1?min) or not before resin cement placement. Dual-cure resin cement was mixed and inserted in tubes (0.75?mm diameter?×?1?mm height) that were positioned over primed ceramic surfaces. Micro-shear testing was performed using a universal testing machine. Bond strength data were analyzed using two-way ANOVA and Tukey’s test (5%). Ceramic primer heating did not improve the bond strength of the resin cement to lithium disilicate. Most of ceramic primers did not indicate significant difference in bond strength among them; however, CCP yielded the lowest bond strength among the ceramic primers. In conclusion, when the silane was applied on etched surface the bond strength was higher and heat treatment of silane coupling agents did not affect the bond strength.
期刊介绍:
Applied Adhesion Science focuses on practical applications of adhesives, with special emphasis in fields such as oil industry, aerospace and biomedicine. Topics related to the phenomena of adhesion and the application of adhesive materials are welcome, especially in biomedical areas such as adhesive dentistry. Both theoretical and experimental works are considered for publication. Applied Adhesion Science is a peer-reviewed open access journal published under the SpringerOpen brand. The journal''s open access policy offers a fast publication workflow whilst maintaining rigorous peer review process.