Michael Le, D. Maestri, Bob Jang, Jason Chinnappa, Sol Qurashi
{"title":"全髋关节置换术后早期血清金属离子水平升高","authors":"Michael Le, D. Maestri, Bob Jang, Jason Chinnappa, Sol Qurashi","doi":"10.15438/rr.10.1.238","DOIUrl":null,"url":null,"abstract":"Background: Serum Cobalt (Co) and Chromium (Cr) forms part of the diagnostic process for metallosis following Total Hip Arthroplasty (THA). While knowledge exists on longer term metal ion levels, expected early post-operative rises in serum Co and Cr in Metal-on-Polyethylene (MoP) THAs are currently unknown. This study aims to describe early rises in serum Co and Cr at 6 months postoperatively. Methods: A prospective cohort study of 84 consecutive patients with an uncemented titanium stem from a single THA manufacturer was performed. Patients had either a metal (n=43) or ceramic (n=41) head articulating with a highly cross-linked polyethylene. Serum Co and Cr levels were measured six months post-operatively. Analysis compared mean values between groups and to determined baseline levels. Subgroup analysis investigated the effect of femoral head size and offset on metal ion levels. Results: A mean difference of 0.002259 ppb (95% CI 0.000449-0.004069 ppb; p=0.015) was found when comparing 6-month serum Co in the metal head group compared to baseline. No significant differences were found in serum Cr (p=0.943) at six months post-surgery compared to baseline. Mean serum Co levels were higher in the MoP group compared to the CoP (Ceramic-on-Polyethylene) and auxiliary control group (p=0.012). There were no differences in serum Cr (p=0.976) between the MoP and CoP groups at 6 months post-surgery. Variations in femoral head size and offset did not impact metal ion levels. Conclusion: At six months post-surgery, a higher magnitude of serum Co exists in metal heads when compared to baseline (p=0.015) and to ceramic heads (p=0.012). Further study is required to determine whether serum concentrations of metal ions will continue to increase over time which might leads to implant failure and revision.","PeriodicalId":20884,"journal":{"name":"Reconstructive Review","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Early Post-operative Rises in Serum Metal Ion Levels in Total Hip Arthroplasty\",\"authors\":\"Michael Le, D. Maestri, Bob Jang, Jason Chinnappa, Sol Qurashi\",\"doi\":\"10.15438/rr.10.1.238\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Serum Cobalt (Co) and Chromium (Cr) forms part of the diagnostic process for metallosis following Total Hip Arthroplasty (THA). While knowledge exists on longer term metal ion levels, expected early post-operative rises in serum Co and Cr in Metal-on-Polyethylene (MoP) THAs are currently unknown. This study aims to describe early rises in serum Co and Cr at 6 months postoperatively. Methods: A prospective cohort study of 84 consecutive patients with an uncemented titanium stem from a single THA manufacturer was performed. Patients had either a metal (n=43) or ceramic (n=41) head articulating with a highly cross-linked polyethylene. Serum Co and Cr levels were measured six months post-operatively. Analysis compared mean values between groups and to determined baseline levels. Subgroup analysis investigated the effect of femoral head size and offset on metal ion levels. Results: A mean difference of 0.002259 ppb (95% CI 0.000449-0.004069 ppb; p=0.015) was found when comparing 6-month serum Co in the metal head group compared to baseline. No significant differences were found in serum Cr (p=0.943) at six months post-surgery compared to baseline. Mean serum Co levels were higher in the MoP group compared to the CoP (Ceramic-on-Polyethylene) and auxiliary control group (p=0.012). There were no differences in serum Cr (p=0.976) between the MoP and CoP groups at 6 months post-surgery. Variations in femoral head size and offset did not impact metal ion levels. Conclusion: At six months post-surgery, a higher magnitude of serum Co exists in metal heads when compared to baseline (p=0.015) and to ceramic heads (p=0.012). Further study is required to determine whether serum concentrations of metal ions will continue to increase over time which might leads to implant failure and revision.\",\"PeriodicalId\":20884,\"journal\":{\"name\":\"Reconstructive Review\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-12-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Reconstructive Review\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15438/rr.10.1.238\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Reconstructive Review","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15438/rr.10.1.238","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
背景:血清钴(Co)和铬(Cr)是全髋关节置换术(THA)后金属中毒诊断过程的一部分。虽然对长期金属离子水平有了解,但术后早期在金属对聚乙烯(MoP) tha中血清Co和Cr的预期升高目前尚不清楚。本研究旨在描述术后6个月血清Co和Cr的早期升高。方法:一项前瞻性队列研究,对84例连续使用来自单一THA制造商的未胶结钛干的患者进行了研究。患者采用金属头(n=43)或陶瓷头(n=41)与高度交联聚乙烯连接。术后6个月测定血清Co和Cr水平。分析比较各组之间的平均值和确定的基线水平。亚组分析探讨股骨头大小和偏移量对金属离子水平的影响。结果:平均差值为0.002259 ppb (95% CI 0.000449-0.004069 ppb;p=0.015),比较金属头组6个月血清Co与基线的差异。术后6个月血清Cr与基线比较无显著差异(p=0.943)。MoP组的平均血清Co水平高于CoP (ceramic -on-聚乙烯)组和辅助对照组(p=0.012)。术后6个月MoP组与CoP组血清Cr差异无统计学意义(p=0.976)。股骨头大小和偏移量的变化对金属离子水平没有影响。结论:术后6个月,金属头的血清Co浓度高于基线(p=0.015)和陶瓷头(p=0.012)。需要进一步的研究来确定血清金属离子浓度是否会随着时间的推移而继续增加,这可能导致种植体失败和翻修。
Early Post-operative Rises in Serum Metal Ion Levels in Total Hip Arthroplasty
Background: Serum Cobalt (Co) and Chromium (Cr) forms part of the diagnostic process for metallosis following Total Hip Arthroplasty (THA). While knowledge exists on longer term metal ion levels, expected early post-operative rises in serum Co and Cr in Metal-on-Polyethylene (MoP) THAs are currently unknown. This study aims to describe early rises in serum Co and Cr at 6 months postoperatively. Methods: A prospective cohort study of 84 consecutive patients with an uncemented titanium stem from a single THA manufacturer was performed. Patients had either a metal (n=43) or ceramic (n=41) head articulating with a highly cross-linked polyethylene. Serum Co and Cr levels were measured six months post-operatively. Analysis compared mean values between groups and to determined baseline levels. Subgroup analysis investigated the effect of femoral head size and offset on metal ion levels. Results: A mean difference of 0.002259 ppb (95% CI 0.000449-0.004069 ppb; p=0.015) was found when comparing 6-month serum Co in the metal head group compared to baseline. No significant differences were found in serum Cr (p=0.943) at six months post-surgery compared to baseline. Mean serum Co levels were higher in the MoP group compared to the CoP (Ceramic-on-Polyethylene) and auxiliary control group (p=0.012). There were no differences in serum Cr (p=0.976) between the MoP and CoP groups at 6 months post-surgery. Variations in femoral head size and offset did not impact metal ion levels. Conclusion: At six months post-surgery, a higher magnitude of serum Co exists in metal heads when compared to baseline (p=0.015) and to ceramic heads (p=0.012). Further study is required to determine whether serum concentrations of metal ions will continue to increase over time which might leads to implant failure and revision.