{"title":"基于经验和三维数值模拟的轴向承桩液化特性研究","authors":"A. Zakariya, A. Rifa’i, S. Ismanti","doi":"10.15294/jtsp.v25i1.42954","DOIUrl":null,"url":null,"abstract":"The liquefaction phenomenon affects to bearing capacity losses of building foundations. When liquefaction occurs in loose sandy soils, the pore water pressure increases, and the effective soil stress decreases significantly. This study deals with the bored pile foundation of Kretek 2 bridge, which is located in an area with high vulnerability to liquefaction. The study aimed to estimate the axial load-bearing capacity of the foundation of Kretek 2 bridge under liquefaction conditions. This study compares the results of calculations using empirical approaches with 3D numerical simulation modeling using MIDAS GTS NX. The results of the empirical calculations show a reduction in the axial bearing capacity of the foundation under liquefaction conditions of 2.88-8.16% and 2.63-7.23% for the approach of Reese and Wright 1977 and O’Neill and Reese 1989, respectively. While using 3D numerical modeling, although there was a decrease in skin resistance, there was no significant decrease in the total bearing capacity, and it was still above the design load (3632.563456.02 kN). Based on these results, the bearing capacity of the installed Kretek 2 Bridge foundation is still capable of receiving loads during static and liquefaction states.","PeriodicalId":31108,"journal":{"name":"Jurnal Teknik Sipil dan Perencanaan","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-04-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Behaviour of Axial Bearing Pile under Liquefaction Condition Based on Empirical and 3D Numerical Simulation\",\"authors\":\"A. Zakariya, A. Rifa’i, S. Ismanti\",\"doi\":\"10.15294/jtsp.v25i1.42954\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The liquefaction phenomenon affects to bearing capacity losses of building foundations. When liquefaction occurs in loose sandy soils, the pore water pressure increases, and the effective soil stress decreases significantly. This study deals with the bored pile foundation of Kretek 2 bridge, which is located in an area with high vulnerability to liquefaction. The study aimed to estimate the axial load-bearing capacity of the foundation of Kretek 2 bridge under liquefaction conditions. This study compares the results of calculations using empirical approaches with 3D numerical simulation modeling using MIDAS GTS NX. The results of the empirical calculations show a reduction in the axial bearing capacity of the foundation under liquefaction conditions of 2.88-8.16% and 2.63-7.23% for the approach of Reese and Wright 1977 and O’Neill and Reese 1989, respectively. While using 3D numerical modeling, although there was a decrease in skin resistance, there was no significant decrease in the total bearing capacity, and it was still above the design load (3632.563456.02 kN). Based on these results, the bearing capacity of the installed Kretek 2 Bridge foundation is still capable of receiving loads during static and liquefaction states.\",\"PeriodicalId\":31108,\"journal\":{\"name\":\"Jurnal Teknik Sipil dan Perencanaan\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-04-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jurnal Teknik Sipil dan Perencanaan\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15294/jtsp.v25i1.42954\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Teknik Sipil dan Perencanaan","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15294/jtsp.v25i1.42954","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
液化现象对建筑物地基承载力损失有较大影响。松软砂土发生液化时,孔隙水压力增大,有效土应力显著减小。本文研究的是Kretek 2桥的钻孔灌注桩基础,该桥位于液化易损区。本研究旨在估算液化条件下Kretek 2桥地基的轴向承载能力。本研究将使用经验方法的计算结果与使用MIDAS GTS NX的三维数值模拟建模进行了比较。经验计算结果表明,采用Reese and Wright 1977和O’neill and Reese 1989的方法,液化条件下地基轴向承载力分别降低2.88-8.16%和2.63-7.23%。采用三维数值模拟时,虽然表皮阻力有所降低,但总承载能力没有明显降低,仍高于设计荷载(3632.563456.02 kN)。基于这些结果,已安装的Kretek 2桥基础在静态和液化状态下仍然能够承受载荷。
Behaviour of Axial Bearing Pile under Liquefaction Condition Based on Empirical and 3D Numerical Simulation
The liquefaction phenomenon affects to bearing capacity losses of building foundations. When liquefaction occurs in loose sandy soils, the pore water pressure increases, and the effective soil stress decreases significantly. This study deals with the bored pile foundation of Kretek 2 bridge, which is located in an area with high vulnerability to liquefaction. The study aimed to estimate the axial load-bearing capacity of the foundation of Kretek 2 bridge under liquefaction conditions. This study compares the results of calculations using empirical approaches with 3D numerical simulation modeling using MIDAS GTS NX. The results of the empirical calculations show a reduction in the axial bearing capacity of the foundation under liquefaction conditions of 2.88-8.16% and 2.63-7.23% for the approach of Reese and Wright 1977 and O’Neill and Reese 1989, respectively. While using 3D numerical modeling, although there was a decrease in skin resistance, there was no significant decrease in the total bearing capacity, and it was still above the design load (3632.563456.02 kN). Based on these results, the bearing capacity of the installed Kretek 2 Bridge foundation is still capable of receiving loads during static and liquefaction states.