手动轮椅部件鼓式滚动阻力试验机的研制与标定

IF 0.7 Q4 REHABILITATION
Joseph Ott, M. Marcus, Travis Henderson, Holly Wilson-Jene, London Lee, J. Pearlman
{"title":"手动轮椅部件鼓式滚动阻力试验机的研制与标定","authors":"Joseph Ott, M. Marcus, Travis Henderson, Holly Wilson-Jene, London Lee, J. Pearlman","doi":"10.3233/TAD-200285","DOIUrl":null,"url":null,"abstract":"BACKGROUND: Manual wheelchair users are at a high risk of repetitive strain injuries, carpal tunnel syndrome, and rotator cuff tears due to propelling their wheelchair for mobility. Rolling resistance (RR) is one of the key forces that leads to increased propulsion forces and risk of injuries. OBJECTIVE: To better understand the factors contributing to RR, we iteratively designed, developed, and validated a drum-based testing machine and test method. METHODS: As part of the validation of the system, we tested and compared 4 manual wheelchair wheels under a range of conditions including camber, toe in/out, tire pressure, surfaces, and speed. A treadmill was employed to simulate flat ground RR. RESULTS: A machine was effectively designed, developed, and tested to measure RR. Tire type, surfaces, and toe were found to be the largest contributors to RR. Comparison of the drum-based system to flat ground revealed that an offset can be used to calculate overground RR from drum measurements. CONCLUSIONS: Ongoing work includes performing a comprehensive analysis of the degree to which each factor contributes to RR of commonly used casters and rear-wheels so that the wheelchair sector can work to reduce RR and the associated risk of repetitive strain injuries.","PeriodicalId":22201,"journal":{"name":"Technology and Disability","volume":"1 1","pages":"1-13"},"PeriodicalIF":0.7000,"publicationDate":"2021-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3233/TAD-200285","citationCount":"1","resultStr":"{\"title\":\"Development and calibration of drum-based rolling resistance testing machine for manual wheelchair components\",\"authors\":\"Joseph Ott, M. Marcus, Travis Henderson, Holly Wilson-Jene, London Lee, J. Pearlman\",\"doi\":\"10.3233/TAD-200285\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"BACKGROUND: Manual wheelchair users are at a high risk of repetitive strain injuries, carpal tunnel syndrome, and rotator cuff tears due to propelling their wheelchair for mobility. Rolling resistance (RR) is one of the key forces that leads to increased propulsion forces and risk of injuries. OBJECTIVE: To better understand the factors contributing to RR, we iteratively designed, developed, and validated a drum-based testing machine and test method. METHODS: As part of the validation of the system, we tested and compared 4 manual wheelchair wheels under a range of conditions including camber, toe in/out, tire pressure, surfaces, and speed. A treadmill was employed to simulate flat ground RR. RESULTS: A machine was effectively designed, developed, and tested to measure RR. Tire type, surfaces, and toe were found to be the largest contributors to RR. Comparison of the drum-based system to flat ground revealed that an offset can be used to calculate overground RR from drum measurements. CONCLUSIONS: Ongoing work includes performing a comprehensive analysis of the degree to which each factor contributes to RR of commonly used casters and rear-wheels so that the wheelchair sector can work to reduce RR and the associated risk of repetitive strain injuries.\",\"PeriodicalId\":22201,\"journal\":{\"name\":\"Technology and Disability\",\"volume\":\"1 1\",\"pages\":\"1-13\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2021-03-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3233/TAD-200285\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Technology and Disability\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3233/TAD-200285\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"REHABILITATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Technology and Disability","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3233/TAD-200285","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"REHABILITATION","Score":null,"Total":0}
引用次数: 1

摘要

背景:手动轮椅使用者由于推动轮椅移动而导致重复性劳损、腕管综合征和肩袖撕裂的风险很高。滚动阻力(RR)是导致推进力增加和受伤风险的关键力之一。目的:为了更好地了解导致RR的因素,我们反复设计、开发和验证了一种基于滚筒的测试机和测试方法。方法:作为系统验证的一部分,我们在一系列条件下测试和比较了4个手动轮椅车轮,包括外倾角、前束角、轮胎压力、表面和速度。采用跑步机模拟平地RR。结果:有效地设计、开发并测试了一台测量RR的机器。轮胎类型、表面和脚趾被发现是RR的最大贡献者。基于转鼓的系统与平地的比较表明,偏移量可用于根据转鼓测量值计算地上RR。结论:正在进行的工作包括对每个因素对常用脚轮和后轮RR的影响程度进行全面分析,以便轮椅行业能够努力降低RR和重复性劳损的相关风险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development and calibration of drum-based rolling resistance testing machine for manual wheelchair components
BACKGROUND: Manual wheelchair users are at a high risk of repetitive strain injuries, carpal tunnel syndrome, and rotator cuff tears due to propelling their wheelchair for mobility. Rolling resistance (RR) is one of the key forces that leads to increased propulsion forces and risk of injuries. OBJECTIVE: To better understand the factors contributing to RR, we iteratively designed, developed, and validated a drum-based testing machine and test method. METHODS: As part of the validation of the system, we tested and compared 4 manual wheelchair wheels under a range of conditions including camber, toe in/out, tire pressure, surfaces, and speed. A treadmill was employed to simulate flat ground RR. RESULTS: A machine was effectively designed, developed, and tested to measure RR. Tire type, surfaces, and toe were found to be the largest contributors to RR. Comparison of the drum-based system to flat ground revealed that an offset can be used to calculate overground RR from drum measurements. CONCLUSIONS: Ongoing work includes performing a comprehensive analysis of the degree to which each factor contributes to RR of commonly used casters and rear-wheels so that the wheelchair sector can work to reduce RR and the associated risk of repetitive strain injuries.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Technology and Disability
Technology and Disability Medicine-Rehabilitation
CiteScore
1.40
自引率
20.00%
发文量
19
期刊介绍: Technology and Disability communicates knowledge about the field of assistive technology devices and services, within the context of the lives of end users - persons with disabilities and their family members. While the topics are technical in nature, the articles are written for broad comprehension despite the reader"s education or training. Technology and Disability"s contents cover research and development efforts, education and training programs, service and policy activities and consumer experiences. - The term Technology refers to assistive devices and services. - The term Disability refers to both permanent and temporary functional limitations experienced by people of any age within any circumstance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信