{"title":"研究改装LED灯在长期测试中照明特性的变化","authors":"N. P. Nesterkina, E. Kuznetsov, J. Zhuravleva","doi":"10.21443/1560-9278-2022-25-4-305-312","DOIUrl":null,"url":null,"abstract":"The paper analyzes the results of comparative studies of the lighting characteristics of retrofit LED lamps of the A60 form factor from various manufacturers: Uniel (Russia - China), JazzWay (Russia - China), Philips (Netherlands), Ecola (Russia), Wolta (Germany). During the test period of lamps up to 6,000 hours, the following lighting characteristics were measured: luminous flux, power consumption, pulsation coefficient. The lamps were tested for 6,000 hours of burning at mains voltage of 220 V. The lamps were turned off 4 times a day and turned on again no less than 15 minutes after being turned off. Measurements of the lighting characteristics of the lamps were carried out after 0, 1,000, 2,000, 3,000, 4,000, 6,000 hours of burning. The position of the lamps during the tests is with the base up. The test results show that the measured value of the initial luminous flux of all retrofit LED lamps corresponds to the declared one; a high value of the lumen maintenance after 6,000 hours of burning among retrofit LED lamps has been shown by Uniel LED 10W 4000K (94.5 %), Philips Essential LED 9W 6500K (96.2 %), Wolta LX 12W 3000K (95.3 %), for lamps JazzWay PLED-SP 10W 5000K and Ecola Classic LED 10.2W 4000K lumen maintenance is less than 90 %. According to the test results, only for the Uniel LED 10W 4000K lamp, the measured values of lighting characteristics and pulsation coefficient, including after 6,000 hours of burning, correspond to the declared ones. With a low pulsation coefficient of 2.3 % for this lamp, the lumen maintenance after 6,000 hours is 94.5 %, which corresponds to lumen maintenance code 9 according to state standard (GOST IEC 62612-2019).","PeriodicalId":30200,"journal":{"name":"Vestnik MGTU","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-12-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Studying changes in the lighting characteristics of retrofit LED lamps during long-term testing\",\"authors\":\"N. P. Nesterkina, E. Kuznetsov, J. Zhuravleva\",\"doi\":\"10.21443/1560-9278-2022-25-4-305-312\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper analyzes the results of comparative studies of the lighting characteristics of retrofit LED lamps of the A60 form factor from various manufacturers: Uniel (Russia - China), JazzWay (Russia - China), Philips (Netherlands), Ecola (Russia), Wolta (Germany). During the test period of lamps up to 6,000 hours, the following lighting characteristics were measured: luminous flux, power consumption, pulsation coefficient. The lamps were tested for 6,000 hours of burning at mains voltage of 220 V. The lamps were turned off 4 times a day and turned on again no less than 15 minutes after being turned off. Measurements of the lighting characteristics of the lamps were carried out after 0, 1,000, 2,000, 3,000, 4,000, 6,000 hours of burning. The position of the lamps during the tests is with the base up. The test results show that the measured value of the initial luminous flux of all retrofit LED lamps corresponds to the declared one; a high value of the lumen maintenance after 6,000 hours of burning among retrofit LED lamps has been shown by Uniel LED 10W 4000K (94.5 %), Philips Essential LED 9W 6500K (96.2 %), Wolta LX 12W 3000K (95.3 %), for lamps JazzWay PLED-SP 10W 5000K and Ecola Classic LED 10.2W 4000K lumen maintenance is less than 90 %. According to the test results, only for the Uniel LED 10W 4000K lamp, the measured values of lighting characteristics and pulsation coefficient, including after 6,000 hours of burning, correspond to the declared ones. With a low pulsation coefficient of 2.3 % for this lamp, the lumen maintenance after 6,000 hours is 94.5 %, which corresponds to lumen maintenance code 9 according to state standard (GOST IEC 62612-2019).\",\"PeriodicalId\":30200,\"journal\":{\"name\":\"Vestnik MGTU\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-12-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Vestnik MGTU\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21443/1560-9278-2022-25-4-305-312\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vestnik MGTU","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21443/1560-9278-2022-25-4-305-312","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
本文分析了来自Uniel(俄罗斯-中国)、JazzWay(俄罗斯-中华)、Philips(荷兰)、Ecola(俄罗斯)、Wolta(德国)等不同制造商的A60形状因子改装LED灯的照明特性的比较研究结果。在长达6000小时的灯具测试期间,测量了以下照明特性:光通量、功耗、脉动系数。在220V的电源电压下对这些灯进行了6000小时的燃烧测试。每天关闭4次灯,并在关闭后不少于15分钟再次打开。在燃烧0、1000、2000、3000、4000、6000小时后对这些灯的照明特性进行了测量。测试期间,灯的位置是底座向上。测试结果表明,所有改装LED灯的初始光通量测量值与申报值一致;Uniel LED 10W 4000K(94.5%)、Philips Essential LED 9W 6500K(96.2%)、Wolta LX 12W 3000K(95.3%)显示了改装LED灯在燃烧6000小时后的高流明维持值,JazzWay PLED-SP 10W 5000K和Ecola Classic LED 10.2W 4000K的流明维持低于90%。根据测试结果,只有Uniel LED 10W 4000K灯的照明特性和脉动系数的测量值,包括燃烧6000小时后的测量值与声明值一致。该灯的低脉动系数为2.3%,6000小时后的管腔维持率为94.5%,符合国家标准(GOST IEC 62612-2019)规定的管腔维持代码9。
Studying changes in the lighting characteristics of retrofit LED lamps during long-term testing
The paper analyzes the results of comparative studies of the lighting characteristics of retrofit LED lamps of the A60 form factor from various manufacturers: Uniel (Russia - China), JazzWay (Russia - China), Philips (Netherlands), Ecola (Russia), Wolta (Germany). During the test period of lamps up to 6,000 hours, the following lighting characteristics were measured: luminous flux, power consumption, pulsation coefficient. The lamps were tested for 6,000 hours of burning at mains voltage of 220 V. The lamps were turned off 4 times a day and turned on again no less than 15 minutes after being turned off. Measurements of the lighting characteristics of the lamps were carried out after 0, 1,000, 2,000, 3,000, 4,000, 6,000 hours of burning. The position of the lamps during the tests is with the base up. The test results show that the measured value of the initial luminous flux of all retrofit LED lamps corresponds to the declared one; a high value of the lumen maintenance after 6,000 hours of burning among retrofit LED lamps has been shown by Uniel LED 10W 4000K (94.5 %), Philips Essential LED 9W 6500K (96.2 %), Wolta LX 12W 3000K (95.3 %), for lamps JazzWay PLED-SP 10W 5000K and Ecola Classic LED 10.2W 4000K lumen maintenance is less than 90 %. According to the test results, only for the Uniel LED 10W 4000K lamp, the measured values of lighting characteristics and pulsation coefficient, including after 6,000 hours of burning, correspond to the declared ones. With a low pulsation coefficient of 2.3 % for this lamp, the lumen maintenance after 6,000 hours is 94.5 %, which corresponds to lumen maintenance code 9 according to state standard (GOST IEC 62612-2019).