{"title":"肾细胞癌转移灶扫描时间对CT灌注值的影响","authors":"Chaan S. Ng ,&nbsp;Adam G. Chandler ,&nbsp;Yanwen Chen ,&nbsp;Wei Wei ,&nbsp;Nizar M. Tannir ,&nbsp;Brian P. Hobbs","doi":"10.1016/j.redii.2023.100028","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><p>CT perfusion (CTp) values are affected by CT scan acquisition duration (t<sub>acq</sub>); their reproducibility is adversely affected by uncertainty in their measurement. The objectives were to assess the effects of t<sub>acq</sub> on CTp parameter values in metastases from renal cell carcinoma (mRCC) in thoracic and abdominal locations.</p></div><div><h3>Materials and Methods</h3><p>131 CTp evaluations in 53 patients with mRCC were retrospectively analyzed by distributed parameter modeling to yield tissue blood flow (BF), blood volume (BV), mean transit time (MTT), permeability (PS), and also hepatic arterial perfusion (HAP) and hepatic arterial fraction (HAF) for liver metastases and normal liver, with t<sub>acq</sub> from 25 to 590 s. Penalized piecewise polynomial regression (SPLINE) characterized functional relationships between CTp parameters and acquisition duration, t<sub>acq</sub>. Evidence for time-invariance was evaluated for each parameter at multiple time points by conducting inference on the fitted derivative to assess its proximity to zero as a function of acquisition time. Equivalence testing was implemented with three levels of confidence (low (20%), moderate (70%), high (95%)).</p></div><div><h3>Results</h3><p>Systematic and non-systematic variability was observed for CTp parameter values with limited t<sub>acq</sub>. All parameters in all locations approached increasing stability with increasing t<sub>acq</sub>. PS, HAP and HAF required longer acquisition times than BF, BV and MTT to attain comparable levels of stability. Stabilization tended to require longer acquisition in liver than other tissues. t<sub>acq</sub>=380 s was required to obtain at least moderate level of confidence for all parameters and organs.</p></div><div><h3>Conclusion</h3><p>Increasing t<sub>acq</sub> yields increasingly more stable CT perfusion parameters, and thereby better reproducibility.</p></div>","PeriodicalId":74676,"journal":{"name":"Research in diagnostic and interventional imaging","volume":"6 ","pages":"Article 100028"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Effect of scan duration on CT perfusion values in metastases from renal cell carcinoma\",\"authors\":\"Chaan S. Ng ,&nbsp;Adam G. Chandler ,&nbsp;Yanwen Chen ,&nbsp;Wei Wei ,&nbsp;Nizar M. Tannir ,&nbsp;Brian P. Hobbs\",\"doi\":\"10.1016/j.redii.2023.100028\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objective</h3><p>CT perfusion (CTp) values are affected by CT scan acquisition duration (t<sub>acq</sub>); their reproducibility is adversely affected by uncertainty in their measurement. The objectives were to assess the effects of t<sub>acq</sub> on CTp parameter values in metastases from renal cell carcinoma (mRCC) in thoracic and abdominal locations.</p></div><div><h3>Materials and Methods</h3><p>131 CTp evaluations in 53 patients with mRCC were retrospectively analyzed by distributed parameter modeling to yield tissue blood flow (BF), blood volume (BV), mean transit time (MTT), permeability (PS), and also hepatic arterial perfusion (HAP) and hepatic arterial fraction (HAF) for liver metastases and normal liver, with t<sub>acq</sub> from 25 to 590 s. Penalized piecewise polynomial regression (SPLINE) characterized functional relationships between CTp parameters and acquisition duration, t<sub>acq</sub>. Evidence for time-invariance was evaluated for each parameter at multiple time points by conducting inference on the fitted derivative to assess its proximity to zero as a function of acquisition time. Equivalence testing was implemented with three levels of confidence (low (20%), moderate (70%), high (95%)).</p></div><div><h3>Results</h3><p>Systematic and non-systematic variability was observed for CTp parameter values with limited t<sub>acq</sub>. All parameters in all locations approached increasing stability with increasing t<sub>acq</sub>. PS, HAP and HAF required longer acquisition times than BF, BV and MTT to attain comparable levels of stability. Stabilization tended to require longer acquisition in liver than other tissues. t<sub>acq</sub>=380 s was required to obtain at least moderate level of confidence for all parameters and organs.</p></div><div><h3>Conclusion</h3><p>Increasing t<sub>acq</sub> yields increasingly more stable CT perfusion parameters, and thereby better reproducibility.</p></div>\",\"PeriodicalId\":74676,\"journal\":{\"name\":\"Research in diagnostic and interventional imaging\",\"volume\":\"6 \",\"pages\":\"Article 100028\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Research in diagnostic and interventional imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2772652523000078\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Research in diagnostic and interventional imaging","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2772652523000078","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

目的CT灌注(CTp)值受CT扫描采集时间(tacq)的影响;它们的再现性受到测量不确定性的不利影响。目的是评估tacq对肾细胞癌(mRCC)胸部和腹部转移的CTp参数值的影响。材料与方法通过分布参数模型对53例mRCC患者的131项CTp评估进行回顾性分析,得出肝转移和正常肝的组织血流量(BF)、血容量(BV)、平均转运时间(MTT)、通透性(PS)、肝动脉灌注(HAP)和肝动脉分数(HAF),tacq为25至590 s。惩罚分段多项式回归(SPLINE)表征了CTp参数和采集持续时间tacq之间的函数关系。通过对拟合的导数进行推断,评估其作为采集时间的函数接近零的程度,来评估多个时间点上每个参数的时间不变性证据。采用三个置信水平(低(20%)、中(70%)、高(95%))进行等价性检验。所有位置的所有参数都接近随着tacq的增加而增加的稳定性。PS、HAP和HAF需要比BF、BV和MTT更长的采集时间才能达到可比的稳定性水平。与其他组织相比,稳定往往需要在肝脏中获得更长的时间。需要tacq=380s来获得所有参数和器官的至少中等水平的置信度。结论增加tacq可获得越来越稳定的CT灌注参数,从而获得更好的再现性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effect of scan duration on CT perfusion values in metastases from renal cell carcinoma

Objective

CT perfusion (CTp) values are affected by CT scan acquisition duration (tacq); their reproducibility is adversely affected by uncertainty in their measurement. The objectives were to assess the effects of tacq on CTp parameter values in metastases from renal cell carcinoma (mRCC) in thoracic and abdominal locations.

Materials and Methods

131 CTp evaluations in 53 patients with mRCC were retrospectively analyzed by distributed parameter modeling to yield tissue blood flow (BF), blood volume (BV), mean transit time (MTT), permeability (PS), and also hepatic arterial perfusion (HAP) and hepatic arterial fraction (HAF) for liver metastases and normal liver, with tacq from 25 to 590 s. Penalized piecewise polynomial regression (SPLINE) characterized functional relationships between CTp parameters and acquisition duration, tacq. Evidence for time-invariance was evaluated for each parameter at multiple time points by conducting inference on the fitted derivative to assess its proximity to zero as a function of acquisition time. Equivalence testing was implemented with three levels of confidence (low (20%), moderate (70%), high (95%)).

Results

Systematic and non-systematic variability was observed for CTp parameter values with limited tacq. All parameters in all locations approached increasing stability with increasing tacq. PS, HAP and HAF required longer acquisition times than BF, BV and MTT to attain comparable levels of stability. Stabilization tended to require longer acquisition in liver than other tissues. tacq=380 s was required to obtain at least moderate level of confidence for all parameters and organs.

Conclusion

Increasing tacq yields increasingly more stable CT perfusion parameters, and thereby better reproducibility.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信