{"title":"摘要电絮凝法采用铝(Al)和铜(Cu)电极降低洗衣垃圾中的COD和TSS","authors":"Mirna Desyderia Sumawan","doi":"10.30872/jkm.v18i2.737","DOIUrl":null,"url":null,"abstract":"A research about reduction of COD and TSS from laundry waste with Electrocoagulation method using Al and Cu electrodes in COD and TSS reduction parameters has been done. In this research, the voltage and optimum time determited based on occurred in electrocoagulation process. The determination of COD and TSS in the contact time was 60 minutes with the value of COD was 90.5645% and TSS 63.7279%. The value of voltage optimum was 12 Volt, obtain COD was 90.2392% and TSS 60.7052%.","PeriodicalId":31725,"journal":{"name":"Jurnal Kimia Mulawarman","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-05-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"DECREASING OF COD AND TSS FROM LAUNDRY WASTE USES ALUMINUM (Al) AND COPPER (Cu) ELECTRODES IN THE ELECTROCOAGULATION METHOD\",\"authors\":\"Mirna Desyderia Sumawan\",\"doi\":\"10.30872/jkm.v18i2.737\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A research about reduction of COD and TSS from laundry waste with Electrocoagulation method using Al and Cu electrodes in COD and TSS reduction parameters has been done. In this research, the voltage and optimum time determited based on occurred in electrocoagulation process. The determination of COD and TSS in the contact time was 60 minutes with the value of COD was 90.5645% and TSS 63.7279%. The value of voltage optimum was 12 Volt, obtain COD was 90.2392% and TSS 60.7052%.\",\"PeriodicalId\":31725,\"journal\":{\"name\":\"Jurnal Kimia Mulawarman\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-05-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jurnal Kimia Mulawarman\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.30872/jkm.v18i2.737\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Kimia Mulawarman","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30872/jkm.v18i2.737","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
DECREASING OF COD AND TSS FROM LAUNDRY WASTE USES ALUMINUM (Al) AND COPPER (Cu) ELECTRODES IN THE ELECTROCOAGULATION METHOD
A research about reduction of COD and TSS from laundry waste with Electrocoagulation method using Al and Cu electrodes in COD and TSS reduction parameters has been done. In this research, the voltage and optimum time determited based on occurred in electrocoagulation process. The determination of COD and TSS in the contact time was 60 minutes with the value of COD was 90.5645% and TSS 63.7279%. The value of voltage optimum was 12 Volt, obtain COD was 90.2392% and TSS 60.7052%.