Proteus ISIS仿真功率因数计算用过零检测器

Jumrianto Jumrianto, R. Royan
{"title":"Proteus ISIS仿真功率因数计算用过零检测器","authors":"Jumrianto Jumrianto, R. Royan","doi":"10.14203/j.mev.2021.v12.28-37","DOIUrl":null,"url":null,"abstract":"One of the important parameters for electrical systems is the power factor (cos phi), which is the ratio of the real power (watt) to the apparent power (volt ampere). The best cos phi value is between 0.85 to 1. A resistive load causes the voltage and current in equal phase angle, while the inductive load causes the current to lag behind the voltage. On the other hand, the capacitive load causes the current to precede the voltage (leading). A simulation to determine the power factor of an electrical network can be done with Proteus ISIS software by creating a phase detection circuit. Automatic control can be done by a microcontroller. This simulation circuit can be used as power factor correction, a trigger angle on SCR trigger for DC motor speed control, for rocket launch angle adjuster, to measure the angle of inclination, and other uses relating to angle adjustments.","PeriodicalId":30530,"journal":{"name":"Journal of Mechatronics Electrical Power and Vehicular Technology","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Proteus ISIS simulation for power factor calculation using zero crossing detector\",\"authors\":\"Jumrianto Jumrianto, R. Royan\",\"doi\":\"10.14203/j.mev.2021.v12.28-37\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"One of the important parameters for electrical systems is the power factor (cos phi), which is the ratio of the real power (watt) to the apparent power (volt ampere). The best cos phi value is between 0.85 to 1. A resistive load causes the voltage and current in equal phase angle, while the inductive load causes the current to lag behind the voltage. On the other hand, the capacitive load causes the current to precede the voltage (leading). A simulation to determine the power factor of an electrical network can be done with Proteus ISIS software by creating a phase detection circuit. Automatic control can be done by a microcontroller. This simulation circuit can be used as power factor correction, a trigger angle on SCR trigger for DC motor speed control, for rocket launch angle adjuster, to measure the angle of inclination, and other uses relating to angle adjustments.\",\"PeriodicalId\":30530,\"journal\":{\"name\":\"Journal of Mechatronics Electrical Power and Vehicular Technology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-07-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Mechatronics Electrical Power and Vehicular Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14203/j.mev.2021.v12.28-37\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Mechatronics Electrical Power and Vehicular Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14203/j.mev.2021.v12.28-37","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

电力系统的一个重要参数是功率因数(cos phi),它是实际功率(瓦特)与视在功率(伏安)之比。最好的cos值在0.85到1之间。电阻性负载使电压和电流相角相等,而感性负载使电流滞后于电压。另一方面,容性负载使电流先于电压(前导)。通过创建相位检测电路,可以使用Proteus ISIS软件进行模拟,以确定电网的功率因数。自动控制可以由微控制器完成。该仿真电路可用于功率因数校正、可控硅上的触发角触发、直流电机调速、火箭发射角度调节器、倾斜角测量以及其他与角度调节有关的用途。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Proteus ISIS simulation for power factor calculation using zero crossing detector
One of the important parameters for electrical systems is the power factor (cos phi), which is the ratio of the real power (watt) to the apparent power (volt ampere). The best cos phi value is between 0.85 to 1. A resistive load causes the voltage and current in equal phase angle, while the inductive load causes the current to lag behind the voltage. On the other hand, the capacitive load causes the current to precede the voltage (leading). A simulation to determine the power factor of an electrical network can be done with Proteus ISIS software by creating a phase detection circuit. Automatic control can be done by a microcontroller. This simulation circuit can be used as power factor correction, a trigger angle on SCR trigger for DC motor speed control, for rocket launch angle adjuster, to measure the angle of inclination, and other uses relating to angle adjustments.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.70
自引率
0.00%
发文量
10
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信