{"title":"非粘连性囊性外伤性人工晶状体异位","authors":"Zeli Chen, Yan Wu, Mao-sheng Chen, Zhen Liu","doi":"10.1097/j.jcro.0000000000000076","DOIUrl":null,"url":null,"abstract":"Introduction: This study describes a case of traumatic intraocular lens (IOL) ectopia with retention in the pupil that occurred 2 years after cataract surgery. Patient and Clinical Findings: A 55-year-old man, who underwent cataract surgery 2 years ago, sustained an ocular injury while slapping a bug on the left eyelid, following which he had decreased vision. His IOL shifted out of the capsule and was retained in the pupil. Diagnosis, Intervention, and Outcomes: The patient was diagnosed with IOL ectopia with retention in the pupil. An IOL reposition operation was performed successfully. The IOL was completely returned into the capsule, and postoperatively, his uncorrected distance visual acuity immediately improved to 0.097 logMAR. Conclusions: An IOL could slide out of the nonadhesive capsule under external force even if the capsulorhexis is performed perfectly with a continuous curvilinear circle at the center and the anterior capsule covers the IOL optical surface.","PeriodicalId":14598,"journal":{"name":"JCRS Online Case Reports","volume":"29 1","pages":"e00076"},"PeriodicalIF":0.0000,"publicationDate":"2022-02-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Traumatic intraocular lens ectopia from a nonadhesive capsule\",\"authors\":\"Zeli Chen, Yan Wu, Mao-sheng Chen, Zhen Liu\",\"doi\":\"10.1097/j.jcro.0000000000000076\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction: This study describes a case of traumatic intraocular lens (IOL) ectopia with retention in the pupil that occurred 2 years after cataract surgery. Patient and Clinical Findings: A 55-year-old man, who underwent cataract surgery 2 years ago, sustained an ocular injury while slapping a bug on the left eyelid, following which he had decreased vision. His IOL shifted out of the capsule and was retained in the pupil. Diagnosis, Intervention, and Outcomes: The patient was diagnosed with IOL ectopia with retention in the pupil. An IOL reposition operation was performed successfully. The IOL was completely returned into the capsule, and postoperatively, his uncorrected distance visual acuity immediately improved to 0.097 logMAR. Conclusions: An IOL could slide out of the nonadhesive capsule under external force even if the capsulorhexis is performed perfectly with a continuous curvilinear circle at the center and the anterior capsule covers the IOL optical surface.\",\"PeriodicalId\":14598,\"journal\":{\"name\":\"JCRS Online Case Reports\",\"volume\":\"29 1\",\"pages\":\"e00076\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-02-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JCRS Online Case Reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1097/j.jcro.0000000000000076\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JCRS Online Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/j.jcro.0000000000000076","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

摘要本研究报告一例白内障手术后2年发生外伤性人工晶状体(IOL)异位伴瞳孔潴留。患者和临床表现:一名55岁的男性,两年前接受白内障手术,在左眼睑拍虫时眼部受伤,随后视力下降。他的人工晶状体移出囊并保留在瞳孔中。诊断、干预和结果:患者被诊断为人工晶状体异位并瞳孔内潴留。成功行人工晶状体复位手术。人工晶状体完全返回囊内,术后未矫正距离视力立即提高至0.097 logMAR。结论:即使撕囊过程完美,中心呈连续曲线圆形,前囊覆盖人工晶状体光学表面,人工晶状体也能在外力作用下从非粘连囊中滑出。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Traumatic intraocular lens ectopia from a nonadhesive capsule
Introduction: This study describes a case of traumatic intraocular lens (IOL) ectopia with retention in the pupil that occurred 2 years after cataract surgery. Patient and Clinical Findings: A 55-year-old man, who underwent cataract surgery 2 years ago, sustained an ocular injury while slapping a bug on the left eyelid, following which he had decreased vision. His IOL shifted out of the capsule and was retained in the pupil. Diagnosis, Intervention, and Outcomes: The patient was diagnosed with IOL ectopia with retention in the pupil. An IOL reposition operation was performed successfully. The IOL was completely returned into the capsule, and postoperatively, his uncorrected distance visual acuity immediately improved to 0.097 logMAR. Conclusions: An IOL could slide out of the nonadhesive capsule under external force even if the capsulorhexis is performed perfectly with a continuous curvilinear circle at the center and the anterior capsule covers the IOL optical surface.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
JCRS Online Case Reports
JCRS Online Case Reports Medicine-Ophthalmology
CiteScore
0.30
自引率
0.00%
发文量
22
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信