{"title":"使用C型臂荧光镜检查术中评估后脚对齐。","authors":"","doi":"10.1016/j.jos.2023.08.014","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Hindfoot malalignment can cause various foot and ankle problems. For better surgical performance and correction of hindfoot malalignments, reliable intraoperative determination of hindfoot alignment is essential. However, there is no standard method for the intraoperative assessment of hindfoot alignment. We devised an intraoperative modified Méary posteroanterior (IOPPA) view to assess intraoperative hindfoot alignment. This study aimed to compare this intraoperative method with other radiographic hindfoot alignment measurements.</p></div><div><h3>Methods</h3><p>Thirty-seven patients (47 feet) with various foot and ankle conditions scheduled to undergo surgery were prospectively recruited. Before surgery, the Saltzman, long axial, and modified Méary views were taken in a controlled and standardized fashion. IOPPA views were obtained under simulated weight bearing conditions using C-arm fluoroscopy in the operating room before surgery. The relationship between the IOPPA view and the three radiographic hindfoot alignments was evaluated using Pearson's correlation.</p></div><div><h3>Results</h3><p><span>The mean hindfoot alignment angle was varus 3.50° (CI, varus 1.91 to 5.08) on the Saltzman view, varus 2.00° (CI, varus 0.60 to 3.39) on the long axial view, varus 0.13° (CI, valgus 1.41 to varus 1.67) on the modified Méary view, and varus 1.32° (CI, valgus 0.02 to varus 2.65) on IOPPA view. The IOPPA view and the three other hindfoot alignment views were found to be significantly correlated (</span><em>r</em> = 0.60 for the Saltzman view, <em>r</em> = 0.50 for the long axial view, <em>r</em> = 0.71 for the modified Méary view, <em>P</em> &lt; .05). The intraobserver ICC (Intraclass Correlation Coefficient) value was 0.974 and interobserver ICC (Intraclass Correlation Coefficient) value was 0.988 for the IOPPA view (<em>P</em> &lt; .001).</p></div><div><h3>Conclusion</h3><p>There was a statistically significant correlation between the IOPPA view and the other three hindfoot alignment views. We also found that interobserver and intraobserver ICC values were excellent. This study proposes that the IOPPA view can be used as a reliable intraoperative assessment tool for hindfoot alignment.</p></div><div><h3>Level of evidence</h3><p>Prospective study.</p></div>","PeriodicalId":16939,"journal":{"name":"Journal of Orthopaedic Science","volume":"29 5","pages":"Pages 1248-1254"},"PeriodicalIF":1.5000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Intraoperative assessment of hindfoot alignment using C-arm fluoroscopy\",\"authors\":\"\",\"doi\":\"10.1016/j.jos.2023.08.014\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>Hindfoot malalignment can cause various foot and ankle problems. For better surgical performance and correction of hindfoot malalignments, reliable intraoperative determination of hindfoot alignment is essential. However, there is no standard method for the intraoperative assessment of hindfoot alignment. We devised an intraoperative modified Méary posteroanterior (IOPPA) view to assess intraoperative hindfoot alignment. This study aimed to compare this intraoperative method with other radiographic hindfoot alignment measurements.</p></div><div><h3>Methods</h3><p>Thirty-seven patients (47 feet) with various foot and ankle conditions scheduled to undergo surgery were prospectively recruited. Before surgery, the Saltzman, long axial, and modified Méary views were taken in a controlled and standardized fashion. IOPPA views were obtained under simulated weight bearing conditions using C-arm fluoroscopy in the operating room before surgery. The relationship between the IOPPA view and the three radiographic hindfoot alignments was evaluated using Pearson's correlation.</p></div><div><h3>Results</h3><p><span>The mean hindfoot alignment angle was varus 3.50° (CI, varus 1.91 to 5.08) on the Saltzman view, varus 2.00° (CI, varus 0.60 to 3.39) on the long axial view, varus 0.13° (CI, valgus 1.41 to varus 1.67) on the modified Méary view, and varus 1.32° (CI, valgus 0.02 to varus 2.65) on IOPPA view. The IOPPA view and the three other hindfoot alignment views were found to be significantly correlated (</span><em>r</em> = 0.60 for the Saltzman view, <em>r</em> = 0.50 for the long axial view, <em>r</em> = 0.71 for the modified Méary view, <em>P</em> &lt; .05). The intraobserver ICC (Intraclass Correlation Coefficient) value was 0.974 and interobserver ICC (Intraclass Correlation Coefficient) value was 0.988 for the IOPPA view (<em>P</em> &lt; .001).</p></div><div><h3>Conclusion</h3><p>There was a statistically significant correlation between the IOPPA view and the other three hindfoot alignment views. We also found that interobserver and intraobserver ICC values were excellent. This study proposes that the IOPPA view can be used as a reliable intraoperative assessment tool for hindfoot alignment.</p></div><div><h3>Level of evidence</h3><p>Prospective study.</p></div>\",\"PeriodicalId\":16939,\"journal\":{\"name\":\"Journal of Orthopaedic Science\",\"volume\":\"29 5\",\"pages\":\"Pages 1248-1254\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Orthopaedic Science\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0949265823002531\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedic Science","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0949265823002531","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

背景:后脚错位会导致各种足部和脚踝问题。为了更好的手术性能和矫正后脚对齐不良,术中可靠的后脚对齐测定至关重要。然而,术中评估后脚对齐没有标准的方法。我们设计了一种术中改良的Méary后前(IOPA)视图来评估术中后脚对齐情况。本研究旨在将这种术中方法与其他放射学后足对齐测量方法进行比较。方法:前瞻性地招募了37名(47英尺)患有各种足部和踝关节疾病并计划接受手术的患者。手术前,Saltzman、长轴和改良的Méary视图是以可控和标准化的方式拍摄的。手术前在手术室使用C型臂荧光镜在模拟承重条件下获得IOPA视图。使用Pearson相关性评估IOPA视图与三种放射学后足对齐之间的关系。结果:Saltzman视野下的平均后足排列角为内翻3.50°(CI,内翻1.91至5.08),长轴视野下的内翻2.00°(CI),改良Méary视野下的外翻0.13°(CI1.41至内翻1.67),IOPA视野下的后足内翻1.32°(CI 0.02至内翻2.65)。IOPA视图和其他三个后足对齐视图被发现显著相关(Saltzman视野为0.60,长轴视野为0.50,改良Méary视野为0.71,P结论:IOPA视野与其他三种后足对齐视野之间存在统计学上显著的相关性。我们还发现观察者间和观察者内ICC值非常好。本研究提出,IOPA视野可作为一种可靠的内窥镜用于后足对齐的ative评估工具。证据水平:前瞻性研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Intraoperative assessment of hindfoot alignment using C-arm fluoroscopy

Background

Hindfoot malalignment can cause various foot and ankle problems. For better surgical performance and correction of hindfoot malalignments, reliable intraoperative determination of hindfoot alignment is essential. However, there is no standard method for the intraoperative assessment of hindfoot alignment. We devised an intraoperative modified Méary posteroanterior (IOPPA) view to assess intraoperative hindfoot alignment. This study aimed to compare this intraoperative method with other radiographic hindfoot alignment measurements.

Methods

Thirty-seven patients (47 feet) with various foot and ankle conditions scheduled to undergo surgery were prospectively recruited. Before surgery, the Saltzman, long axial, and modified Méary views were taken in a controlled and standardized fashion. IOPPA views were obtained under simulated weight bearing conditions using C-arm fluoroscopy in the operating room before surgery. The relationship between the IOPPA view and the three radiographic hindfoot alignments was evaluated using Pearson's correlation.

Results

The mean hindfoot alignment angle was varus 3.50° (CI, varus 1.91 to 5.08) on the Saltzman view, varus 2.00° (CI, varus 0.60 to 3.39) on the long axial view, varus 0.13° (CI, valgus 1.41 to varus 1.67) on the modified Méary view, and varus 1.32° (CI, valgus 0.02 to varus 2.65) on IOPPA view. The IOPPA view and the three other hindfoot alignment views were found to be significantly correlated (r = 0.60 for the Saltzman view, r = 0.50 for the long axial view, r = 0.71 for the modified Méary view, P < .05). The intraobserver ICC (Intraclass Correlation Coefficient) value was 0.974 and interobserver ICC (Intraclass Correlation Coefficient) value was 0.988 for the IOPPA view (P < .001).

Conclusion

There was a statistically significant correlation between the IOPPA view and the other three hindfoot alignment views. We also found that interobserver and intraobserver ICC values were excellent. This study proposes that the IOPPA view can be used as a reliable intraoperative assessment tool for hindfoot alignment.

Level of evidence

Prospective study.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Orthopaedic Science
Journal of Orthopaedic Science 医学-整形外科
CiteScore
3.00
自引率
0.00%
发文量
290
审稿时长
90 days
期刊介绍: The Journal of Orthopaedic Science is the official peer-reviewed journal of the Japanese Orthopaedic Association. The journal publishes the latest researches and topical debates in all fields of clinical and experimental orthopaedics, including musculoskeletal medicine, sports medicine, locomotive syndrome, trauma, paediatrics, oncology and biomaterials, as well as basic researches.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信