经胸超声心动图在新生儿缩窄术前评估中的应用:与先进成像技术相关的限制风险。

IF 1.2 Q3 PEDIATRICS
Pediatric quality & safety Pub Date : 2023-09-28 eCollection Date: 2023-09-01 DOI:10.1097/pq9.0000000000000682
Christina L Benjamin, Erik G Ellsworth, Roosevelt Bryant, Deepti P Bhat
{"title":"经胸超声心动图在新生儿缩窄术前评估中的应用:与先进成像技术相关的限制风险。","authors":"Christina L Benjamin,&nbsp;Erik G Ellsworth,&nbsp;Roosevelt Bryant,&nbsp;Deepti P Bhat","doi":"10.1097/pq9.0000000000000682","DOIUrl":null,"url":null,"abstract":"<p><p>A newborn male child with prenatally identified aortic arch hypoplasia presented to our facility for cardiac management. He had been started on prostaglandins at the delivery facility and was subsequently placed on a high-flow nasal cannula due to associated apnea. On the day of life three, the patient underwent cardiac computed tomography scan for delineation of his anatomy. The patient remained intubated after his imaging study in anticipation of surgical intervention, which took place at the age of 5 days. The patient required a peritoneal dialysis catheter placement 2 days after his procedure due to oliguria. He progressed into renal failure requiring continuous renal replacement therapy. This patient was subsequently discussed at our departmental morbidity and mortality conference. The short time frame between contrast administration for the computed tomography and surgical intervention was thought to have contributed to his renal failure. We discussed the adequacy of transverse aortic arch imaging by echocardiogram and the utility of advanced imaging in the fragile neonatal period. This discussion resulted in our department asking, \"Is transthoracic echocardiography accurate when diagnosing and characterizing aortic coarctation at our institution? Are advanced imaging studies necessary in instances of simple coarctation?\"</p>","PeriodicalId":74412,"journal":{"name":"Pediatric quality & safety","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2023-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10538927/pdf/","citationCount":"0","resultStr":"{\"title\":\"Transthoracic Echocardiography in the Preoperative Assessment of Newborn Coarctation: Limiting Risks Associated with Advanced Imaging Techniques.\",\"authors\":\"Christina L Benjamin,&nbsp;Erik G Ellsworth,&nbsp;Roosevelt Bryant,&nbsp;Deepti P Bhat\",\"doi\":\"10.1097/pq9.0000000000000682\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A newborn male child with prenatally identified aortic arch hypoplasia presented to our facility for cardiac management. He had been started on prostaglandins at the delivery facility and was subsequently placed on a high-flow nasal cannula due to associated apnea. On the day of life three, the patient underwent cardiac computed tomography scan for delineation of his anatomy. The patient remained intubated after his imaging study in anticipation of surgical intervention, which took place at the age of 5 days. The patient required a peritoneal dialysis catheter placement 2 days after his procedure due to oliguria. He progressed into renal failure requiring continuous renal replacement therapy. This patient was subsequently discussed at our departmental morbidity and mortality conference. The short time frame between contrast administration for the computed tomography and surgical intervention was thought to have contributed to his renal failure. We discussed the adequacy of transverse aortic arch imaging by echocardiogram and the utility of advanced imaging in the fragile neonatal period. This discussion resulted in our department asking, \\\"Is transthoracic echocardiography accurate when diagnosing and characterizing aortic coarctation at our institution? Are advanced imaging studies necessary in instances of simple coarctation?\\\"</p>\",\"PeriodicalId\":74412,\"journal\":{\"name\":\"Pediatric quality & safety\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2023-09-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10538927/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pediatric quality & safety\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1097/pq9.0000000000000682\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/9/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"PEDIATRICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pediatric quality & safety","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/pq9.0000000000000682","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/9/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"PEDIATRICS","Score":null,"Total":0}
引用次数: 0

摘要

一名出生前经鉴定为主动脉弓发育不全的新生男婴被送往我们的心脏管理机构。他在分娩设施开始服用前列腺素,随后由于相关的呼吸暂停而被放置在高流量鼻插管上。在生命三的那天,患者接受了心脏计算机断层扫描,以描绘他的解剖结构。该患者在5天大时进行了影像学研究,预计会进行手术干预,之后仍在插管。由于少尿,患者在手术后2天需要放置腹膜透析导管。他进展为肾衰竭,需要持续进行肾脏替代治疗。该患者随后在我们的部门发病率和死亡率会议上进行了讨论。计算机断层扫描造影剂给药和手术干预之间的短时间被认为是导致他的肾衰竭的原因。我们讨论了超声心动图横主动脉弓成像的充分性以及高级成像在新生儿脆弱期的应用。这一讨论导致我们部门提出问题:“在我们机构诊断和表征主动脉缩窄时,经胸超声心动图是否准确?在简单缩窄的情况下,是否需要进行高级成像研究?”
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Transthoracic Echocardiography in the Preoperative Assessment of Newborn Coarctation: Limiting Risks Associated with Advanced Imaging Techniques.

A newborn male child with prenatally identified aortic arch hypoplasia presented to our facility for cardiac management. He had been started on prostaglandins at the delivery facility and was subsequently placed on a high-flow nasal cannula due to associated apnea. On the day of life three, the patient underwent cardiac computed tomography scan for delineation of his anatomy. The patient remained intubated after his imaging study in anticipation of surgical intervention, which took place at the age of 5 days. The patient required a peritoneal dialysis catheter placement 2 days after his procedure due to oliguria. He progressed into renal failure requiring continuous renal replacement therapy. This patient was subsequently discussed at our departmental morbidity and mortality conference. The short time frame between contrast administration for the computed tomography and surgical intervention was thought to have contributed to his renal failure. We discussed the adequacy of transverse aortic arch imaging by echocardiogram and the utility of advanced imaging in the fragile neonatal period. This discussion resulted in our department asking, "Is transthoracic echocardiography accurate when diagnosing and characterizing aortic coarctation at our institution? Are advanced imaging studies necessary in instances of simple coarctation?"

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.20
自引率
0.00%
发文量
0
审稿时长
20 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信