{"title":"基于离体猪主动脉模型,内膜瓣的位置、长度和厚度在Stanford B型主动脉夹层传播中的作用。","authors":"Shuangjing Wang, Heyue Jia, Yifu Xi, Pengfei Yuan, Mingwei Wu, Wei Guo, Duanduan Chen, Jiang Xiong","doi":"10.1177/15266028231199930","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To explore the role of location, length, and thickness of the intimal flap in the propagation of Stanford type B aortic dissection (TBAD) based on ex vivo porcine aorta models based on ex vivo porcine aorta models.</p><p><strong>Materials and methods: </strong>The porcine aortas were harvested and randomly divided into 6 groups to create various TBAD aortic models. We constructed intimal flaps for different locations (group A [entry tear on outer curvature] and group B [entry tear on inner curvature]), lengths (group C [long] and group D [short]), and thicknesses (group E [thick] and group F [thin]). For the ex vivo perfusion experiments conducted on model aortas, an experimental circulation loop (ECL) was employed. The pressure in false lumen (FL) was constantly monitored. A comparison was made between the morphological data collected before and after the experiment to quantify the changes in the FL after the experiment.</p><p><strong>Results: </strong>Compared the results with group B, the mean peak pressures of the FL in group A were lower (106.87±15.55 vs. 124.01±22.75 mm Hg, p=0.028). The mean axial propagation length in group A was shown to be shorter than that of group B (88.14±33.38 vs. 197.43±41.65 mm, p<0.001). The mean peak pressure was higher in group C than in group D (144.04±19.37 vs. 92.51±26.70 mm Hg, p<0.001). The mean peak pressure of group E was higher than that of group F (160.83±32.83 vs. 109.33±15.62 mm Hg, p<0.001), as was the mean axial propagation length of group E (143.11±39.73 vs. 100.45±35.44 mm, p=0.021). According to the results of multivariable linear regression, axial propagation length=45.873-0.703×length of initial FL+0.863× peak pressure (p<0.001).</p><p><strong>Conclusion: </strong>There was a relationship between FL propagation and the location, length, and thickness of the intimal flap. The axial propagation length was related to the length of the intimal flap and the peak pressure of propagation. It may be helpful to evaluate the risk of propagation in patients with TBAD.Clinical ImpactThis study found that the locations, lengths, and thickness of the intimal flap significantly contributed to propagation pressure of FL. Using dissection flap characteristics, a physician can predict FL development in a patient and formulate a treatment plan.The purpose was to investigate the relationship between the dissection flap characteristics (location, length, and thickness) and the propagation of the FL, which is not clear at present. This study employed porcine models to create an experimental circulation loop. The perfusion experiment was conducted using a FL without distal re-entry and a non-pulsating flow.</p>","PeriodicalId":50210,"journal":{"name":"Journal of Endovascular Therapy","volume":" ","pages":"1214-1223"},"PeriodicalIF":1.5000,"publicationDate":"2025-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Role of Location, Length, and Thickness of the Intimal Flap in the Propagation of Stanford Type B Aortic Dissection Based on Ex Vivo Porcine Aorta Models.\",\"authors\":\"Shuangjing Wang, Heyue Jia, Yifu Xi, Pengfei Yuan, Mingwei Wu, Wei Guo, Duanduan Chen, Jiang Xiong\",\"doi\":\"10.1177/15266028231199930\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To explore the role of location, length, and thickness of the intimal flap in the propagation of Stanford type B aortic dissection (TBAD) based on ex vivo porcine aorta models based on ex vivo porcine aorta models.</p><p><strong>Materials and methods: </strong>The porcine aortas were harvested and randomly divided into 6 groups to create various TBAD aortic models. We constructed intimal flaps for different locations (group A [entry tear on outer curvature] and group B [entry tear on inner curvature]), lengths (group C [long] and group D [short]), and thicknesses (group E [thick] and group F [thin]). For the ex vivo perfusion experiments conducted on model aortas, an experimental circulation loop (ECL) was employed. The pressure in false lumen (FL) was constantly monitored. A comparison was made between the morphological data collected before and after the experiment to quantify the changes in the FL after the experiment.</p><p><strong>Results: </strong>Compared the results with group B, the mean peak pressures of the FL in group A were lower (106.87±15.55 vs. 124.01±22.75 mm Hg, p=0.028). The mean axial propagation length in group A was shown to be shorter than that of group B (88.14±33.38 vs. 197.43±41.65 mm, p<0.001). The mean peak pressure was higher in group C than in group D (144.04±19.37 vs. 92.51±26.70 mm Hg, p<0.001). The mean peak pressure of group E was higher than that of group F (160.83±32.83 vs. 109.33±15.62 mm Hg, p<0.001), as was the mean axial propagation length of group E (143.11±39.73 vs. 100.45±35.44 mm, p=0.021). According to the results of multivariable linear regression, axial propagation length=45.873-0.703×length of initial FL+0.863× peak pressure (p<0.001).</p><p><strong>Conclusion: </strong>There was a relationship between FL propagation and the location, length, and thickness of the intimal flap. The axial propagation length was related to the length of the intimal flap and the peak pressure of propagation. It may be helpful to evaluate the risk of propagation in patients with TBAD.Clinical ImpactThis study found that the locations, lengths, and thickness of the intimal flap significantly contributed to propagation pressure of FL. Using dissection flap characteristics, a physician can predict FL development in a patient and formulate a treatment plan.The purpose was to investigate the relationship between the dissection flap characteristics (location, length, and thickness) and the propagation of the FL, which is not clear at present. This study employed porcine models to create an experimental circulation loop. The perfusion experiment was conducted using a FL without distal re-entry and a non-pulsating flow.</p>\",\"PeriodicalId\":50210,\"journal\":{\"name\":\"Journal of Endovascular Therapy\",\"volume\":\" \",\"pages\":\"1214-1223\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2025-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Endovascular Therapy\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/15266028231199930\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/9/20 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"PERIPHERAL VASCULAR DISEASE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Endovascular Therapy","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15266028231199930","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/9/20 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0
摘要
目的:基于离体猪主动脉模型和离体猪动脉模型,探讨内膜瓣的位置、长度和厚度在斯坦福B型主动脉夹层(TBAD)传播中的作用。材料和方法:取猪主动脉,随机分为6组,建立不同的TBAD主动脉模型。我们构建了不同位置(A组[外曲进入撕裂]和B组[内曲进入撕裂]])、长度(C组[长]和D组[短])和厚度(E组[厚]和F组[薄])的内膜瓣。对于在模型主动脉上进行的离体灌注实验,采用了实验循环回路(ECL)。持续监测假腔(FL)内的压力。在实验前后收集的形态学数据之间进行比较,以量化实验后FL的变化。结果:与B组比较,A组FL的平均峰值压力较低(106.87±15.55 vs.124.01±22.75 mm Hg,p=0.028)。A组的平均轴向传播长度比B组短(88.14±33.38 vs.197.43±41.65 mm,P结论:FL的传播与内膜瓣的位置、长度和厚度有关。轴向传播长度与内膜瓣长度和传播峰值压力有关。这可能有助于评估TBAD患者的传播风险。临床影响:本研究发现内膜瓣的长度和厚度对FL的传播压力有显著影响。利用剥离瓣的特性,医生可以预测患者的FL发展并制定治疗计划。目的是研究夹层皮瓣的特征(位置、长度和厚度)与FL传播之间的关系,目前尚不清楚。这项研究采用了猪模型来创建一个实验循环回路。灌注实验使用FL进行,没有远端再进入和非脉动流。
The Role of Location, Length, and Thickness of the Intimal Flap in the Propagation of Stanford Type B Aortic Dissection Based on Ex Vivo Porcine Aorta Models.
Purpose: To explore the role of location, length, and thickness of the intimal flap in the propagation of Stanford type B aortic dissection (TBAD) based on ex vivo porcine aorta models based on ex vivo porcine aorta models.
Materials and methods: The porcine aortas were harvested and randomly divided into 6 groups to create various TBAD aortic models. We constructed intimal flaps for different locations (group A [entry tear on outer curvature] and group B [entry tear on inner curvature]), lengths (group C [long] and group D [short]), and thicknesses (group E [thick] and group F [thin]). For the ex vivo perfusion experiments conducted on model aortas, an experimental circulation loop (ECL) was employed. The pressure in false lumen (FL) was constantly monitored. A comparison was made between the morphological data collected before and after the experiment to quantify the changes in the FL after the experiment.
Results: Compared the results with group B, the mean peak pressures of the FL in group A were lower (106.87±15.55 vs. 124.01±22.75 mm Hg, p=0.028). The mean axial propagation length in group A was shown to be shorter than that of group B (88.14±33.38 vs. 197.43±41.65 mm, p<0.001). The mean peak pressure was higher in group C than in group D (144.04±19.37 vs. 92.51±26.70 mm Hg, p<0.001). The mean peak pressure of group E was higher than that of group F (160.83±32.83 vs. 109.33±15.62 mm Hg, p<0.001), as was the mean axial propagation length of group E (143.11±39.73 vs. 100.45±35.44 mm, p=0.021). According to the results of multivariable linear regression, axial propagation length=45.873-0.703×length of initial FL+0.863× peak pressure (p<0.001).
Conclusion: There was a relationship between FL propagation and the location, length, and thickness of the intimal flap. The axial propagation length was related to the length of the intimal flap and the peak pressure of propagation. It may be helpful to evaluate the risk of propagation in patients with TBAD.Clinical ImpactThis study found that the locations, lengths, and thickness of the intimal flap significantly contributed to propagation pressure of FL. Using dissection flap characteristics, a physician can predict FL development in a patient and formulate a treatment plan.The purpose was to investigate the relationship between the dissection flap characteristics (location, length, and thickness) and the propagation of the FL, which is not clear at present. This study employed porcine models to create an experimental circulation loop. The perfusion experiment was conducted using a FL without distal re-entry and a non-pulsating flow.
期刊介绍:
The Journal of Endovascular Therapy (formerly the Journal of Endovascular Surgery) was established in 1994 as a forum for all physicians, scientists, and allied healthcare professionals who are engaged or interested in peripheral endovascular techniques and technology. An official publication of the International Society of Endovascular Specialists (ISEVS), the Journal of Endovascular Therapy publishes peer-reviewed articles of interest to clinicians and researchers in the field of peripheral endovascular interventions.