鼻内窥镜下眶内复位治疗孤立性爆裂骨折。

Sea-Yuong Jeon, Jae Hwan Kwon, Jin Pyeong Kim, Seong Ki Ahn, Jung Je Park, Dong Gu Hur, Seong Wook Seo
{"title":"鼻内窥镜下眶内复位治疗孤立性爆裂骨折。","authors":"Sea-Yuong Jeon,&nbsp;Jae Hwan Kwon,&nbsp;Jin Pyeong Kim,&nbsp;Seong Ki Ahn,&nbsp;Jung Je Park,&nbsp;Dong Gu Hur,&nbsp;Seong Wook Seo","doi":"10.1080/03655230701624962","DOIUrl":null,"url":null,"abstract":"<p><strong>Conclusion: </strong>Endoscopic intranasal reduction of the orbital floor with a detachable temporary balloon, or of the medial orbital wall with a silastic sheet and Merocel packing, provided good functional results and definite advantages. We suggest that these techniques are another surgical alternative for isolated orbital floor or medial wall blowout fractures that do not accompany any associated fractures of the orbital rim.</p><p><strong>Objectives: </strong>Extended applications of endoscopic sinus surgery have reported endoscopic intranasal reduction or reconstruction of the orbital wall with good functional and cosmetic results. We present our experience with endoscopic intranasal reduction of the orbit in isolated orbital floor and/or medial wall blowout fractures, treated by reduction of the orbital floor with a detachable temporary balloon, or of the medial orbital wall with a silastic sheet and Merocel packing.</p><p><strong>Subjects and methods: </strong>Floor reduction: After creating a wide middle meatal antrostomy, herniated orbital contents and fracture-displaced floor are mobilized and reduced. The orbital floor is supported by a saline filled balloon, which is connected with an infant feeding catheter and passed through the middle meatal antrostoma. After confirming the reduction of the orbital floor by postoperative CT, the catheter is ligated and cut in short to keep it in the nasal cavity. Medial wall reduction: After completing an intranasal ethmoidectomy, herniated orbital contents and fractured lamina papyracea are mobilized and reduced. The shape of the medial orbital wall is fixed by a silastic sheet and Merocel packing saturated with an antibiotic solution. Surgery was performed when the eye function could be accurately assessed, usually at 7 to 10 days following the injury. Temporary supporting of the orbital wall with a detachable temporary balloon, or a silastic sheet and Merocel packing was removed 4 weeks after surgery in the out-patient clinic.</p><p><strong>Results: </strong>We have experienced 40 cases of endoscopic intranasal reduction of the orbit in blowout fractures. CT scan confirmed isolated orbital floor fracture in 11 patients, isolated medial wall fracture in 17 patients, and combined fractures of the orbital floor and the medial wall in 12 patients. Twenty five patients had diplopia, 20 patients had limitation of eye movement, and 14 patients developed enophthalmos. Thirty three of the 40 patients recovered completely without any residual eye symptoms or complications.</p>","PeriodicalId":7027,"journal":{"name":"Acta oto-laryngologica. Supplementum","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2007-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/03655230701624962","citationCount":"16","resultStr":"{\"title\":\"Endoscopic intranasal reduction of the orbit in isolated blowout fractures.\",\"authors\":\"Sea-Yuong Jeon,&nbsp;Jae Hwan Kwon,&nbsp;Jin Pyeong Kim,&nbsp;Seong Ki Ahn,&nbsp;Jung Je Park,&nbsp;Dong Gu Hur,&nbsp;Seong Wook Seo\",\"doi\":\"10.1080/03655230701624962\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Conclusion: </strong>Endoscopic intranasal reduction of the orbital floor with a detachable temporary balloon, or of the medial orbital wall with a silastic sheet and Merocel packing, provided good functional results and definite advantages. We suggest that these techniques are another surgical alternative for isolated orbital floor or medial wall blowout fractures that do not accompany any associated fractures of the orbital rim.</p><p><strong>Objectives: </strong>Extended applications of endoscopic sinus surgery have reported endoscopic intranasal reduction or reconstruction of the orbital wall with good functional and cosmetic results. We present our experience with endoscopic intranasal reduction of the orbit in isolated orbital floor and/or medial wall blowout fractures, treated by reduction of the orbital floor with a detachable temporary balloon, or of the medial orbital wall with a silastic sheet and Merocel packing.</p><p><strong>Subjects and methods: </strong>Floor reduction: After creating a wide middle meatal antrostomy, herniated orbital contents and fracture-displaced floor are mobilized and reduced. The orbital floor is supported by a saline filled balloon, which is connected with an infant feeding catheter and passed through the middle meatal antrostoma. After confirming the reduction of the orbital floor by postoperative CT, the catheter is ligated and cut in short to keep it in the nasal cavity. Medial wall reduction: After completing an intranasal ethmoidectomy, herniated orbital contents and fractured lamina papyracea are mobilized and reduced. The shape of the medial orbital wall is fixed by a silastic sheet and Merocel packing saturated with an antibiotic solution. Surgery was performed when the eye function could be accurately assessed, usually at 7 to 10 days following the injury. Temporary supporting of the orbital wall with a detachable temporary balloon, or a silastic sheet and Merocel packing was removed 4 weeks after surgery in the out-patient clinic.</p><p><strong>Results: </strong>We have experienced 40 cases of endoscopic intranasal reduction of the orbit in blowout fractures. CT scan confirmed isolated orbital floor fracture in 11 patients, isolated medial wall fracture in 17 patients, and combined fractures of the orbital floor and the medial wall in 12 patients. Twenty five patients had diplopia, 20 patients had limitation of eye movement, and 14 patients developed enophthalmos. Thirty three of the 40 patients recovered completely without any residual eye symptoms or complications.</p>\",\"PeriodicalId\":7027,\"journal\":{\"name\":\"Acta oto-laryngologica. Supplementum\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/03655230701624962\",\"citationCount\":\"16\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta oto-laryngologica. Supplementum\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/03655230701624962\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta oto-laryngologica. Supplementum","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/03655230701624962","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16

摘要

结论:鼻内窥镜下用可拆卸的临时球囊对眶底进行复位,或用硅橡胶片和Merocel填充物对眶内壁进行复位,具有良好的功能效果和明显的优势。我们建议这些技术是治疗孤立性眶底或内侧壁爆裂性骨折的另一种手术选择,这些骨折不伴有任何相关的眶缘骨折。目的:鼻内窥镜手术的广泛应用已经报道了鼻内窥镜眶壁复位或重建,具有良好的功能和美容效果。我们在鼻内窥镜下对孤立性眶底和/或内侧壁爆裂性骨折进行眶内复位的经验,治疗方法是用可拆卸的临时球囊复位眶底,或用硅橡胶片和Merocel填充物复位眶内壁。目标和方法:底复位:在创建一个宽的中间金属窦口后,将眶内容物突出和骨折移位的底移动并复位。眶底由一个充满生理盐水的球囊支撑,球囊与婴儿喂养导管连接并穿过中间金属窦口。术后CT确认眶底复位后,结扎并剪短导管,使其留在鼻腔内。内侧壁复位:完成鼻内筛切除术后,眶内内容物突出和纸莎草板骨折被移动和复位。内侧眶壁的形状由硅橡胶片和含抗生素溶液的墨罗塞尔填充物固定。通常在受伤后7至10天,当眼睛功能可以准确评估时进行手术。用可拆卸的临时球囊或胶布和Merocel填充物临时支撑眼眶壁,于手术后4周在门诊取出。结果:采用鼻内窥镜下眶内固定术治疗爆裂性骨折40例。CT扫描证实孤立性眶底骨折11例,孤立性内侧壁骨折17例,眶底与内侧壁合并骨折12例。复视25例,眼球运动受限20例,眼球内陷14例。40例患者中有33例完全康复,没有任何残留的眼部症状或并发症。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Endoscopic intranasal reduction of the orbit in isolated blowout fractures.

Conclusion: Endoscopic intranasal reduction of the orbital floor with a detachable temporary balloon, or of the medial orbital wall with a silastic sheet and Merocel packing, provided good functional results and definite advantages. We suggest that these techniques are another surgical alternative for isolated orbital floor or medial wall blowout fractures that do not accompany any associated fractures of the orbital rim.

Objectives: Extended applications of endoscopic sinus surgery have reported endoscopic intranasal reduction or reconstruction of the orbital wall with good functional and cosmetic results. We present our experience with endoscopic intranasal reduction of the orbit in isolated orbital floor and/or medial wall blowout fractures, treated by reduction of the orbital floor with a detachable temporary balloon, or of the medial orbital wall with a silastic sheet and Merocel packing.

Subjects and methods: Floor reduction: After creating a wide middle meatal antrostomy, herniated orbital contents and fracture-displaced floor are mobilized and reduced. The orbital floor is supported by a saline filled balloon, which is connected with an infant feeding catheter and passed through the middle meatal antrostoma. After confirming the reduction of the orbital floor by postoperative CT, the catheter is ligated and cut in short to keep it in the nasal cavity. Medial wall reduction: After completing an intranasal ethmoidectomy, herniated orbital contents and fractured lamina papyracea are mobilized and reduced. The shape of the medial orbital wall is fixed by a silastic sheet and Merocel packing saturated with an antibiotic solution. Surgery was performed when the eye function could be accurately assessed, usually at 7 to 10 days following the injury. Temporary supporting of the orbital wall with a detachable temporary balloon, or a silastic sheet and Merocel packing was removed 4 weeks after surgery in the out-patient clinic.

Results: We have experienced 40 cases of endoscopic intranasal reduction of the orbit in blowout fractures. CT scan confirmed isolated orbital floor fracture in 11 patients, isolated medial wall fracture in 17 patients, and combined fractures of the orbital floor and the medial wall in 12 patients. Twenty five patients had diplopia, 20 patients had limitation of eye movement, and 14 patients developed enophthalmos. Thirty three of the 40 patients recovered completely without any residual eye symptoms or complications.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信