经颅磁刺激(TMS)诱发外周肌肉活动时记录的生物磁信号。

IF 1.3 4区 医学 Q4 ENGINEERING, BIOMEDICAL
Geoffrey Z Iwata, Yinan Hu, Arne Wickenbrock, Tilmann Sander, Muthuraman Muthuraman, Venkata Chaitanya Chirumamilla, Sergiu Groppa, Qishan Liu, Dmitry Budker
{"title":"经颅磁刺激(TMS)诱发外周肌肉活动时记录的生物磁信号。","authors":"Geoffrey Z Iwata,&nbsp;Yinan Hu,&nbsp;Arne Wickenbrock,&nbsp;Tilmann Sander,&nbsp;Muthuraman Muthuraman,&nbsp;Venkata Chaitanya Chirumamilla,&nbsp;Sergiu Groppa,&nbsp;Qishan Liu,&nbsp;Dmitry Budker","doi":"10.1515/bmt-2021-0019","DOIUrl":null,"url":null,"abstract":"<p><p>Transcranial magnetic stimulation (TMS) has widespread clinical applications from diagnosis to treatment. We combined TMS with non-contact magnetic detection of TMS-evoked muscle activity in peripheral limbs to explore a new diagnostic modality that enhances the utility of TMS as a clinical tool by leveraging technological advances in magnetometry. We recorded measurements in a regular hospital room using an array of optically pumped magnetometers (OPMs) inside a portable shield that encloses only the forearm and hand of the subject. We present magnetomyograms (MMG)s of TMS-evoked movement in a human hand, together with a simultaneous surface electromyograph (EMG) data. The biomagnetic signals recorded in the MMG provides detailed spatial and temporal information that is complementary to that of the electric signal channels. Moreover, we identify features in the magnetic recording beyond that of the EMG. This system demonstrates the value of biomagnetic signals in TMS-based clinical approaches and widens its availability and practical potential.</p>","PeriodicalId":8900,"journal":{"name":"Biomedical Engineering / Biomedizinische Technik","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2022-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Biomagnetic signals recorded during transcranial magnetic stimulation (TMS)-evoked peripheral muscular activity.\",\"authors\":\"Geoffrey Z Iwata,&nbsp;Yinan Hu,&nbsp;Arne Wickenbrock,&nbsp;Tilmann Sander,&nbsp;Muthuraman Muthuraman,&nbsp;Venkata Chaitanya Chirumamilla,&nbsp;Sergiu Groppa,&nbsp;Qishan Liu,&nbsp;Dmitry Budker\",\"doi\":\"10.1515/bmt-2021-0019\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Transcranial magnetic stimulation (TMS) has widespread clinical applications from diagnosis to treatment. We combined TMS with non-contact magnetic detection of TMS-evoked muscle activity in peripheral limbs to explore a new diagnostic modality that enhances the utility of TMS as a clinical tool by leveraging technological advances in magnetometry. We recorded measurements in a regular hospital room using an array of optically pumped magnetometers (OPMs) inside a portable shield that encloses only the forearm and hand of the subject. We present magnetomyograms (MMG)s of TMS-evoked movement in a human hand, together with a simultaneous surface electromyograph (EMG) data. The biomagnetic signals recorded in the MMG provides detailed spatial and temporal information that is complementary to that of the electric signal channels. Moreover, we identify features in the magnetic recording beyond that of the EMG. This system demonstrates the value of biomagnetic signals in TMS-based clinical approaches and widens its availability and practical potential.</p>\",\"PeriodicalId\":8900,\"journal\":{\"name\":\"Biomedical Engineering / Biomedizinische Technik\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2022-08-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomedical Engineering / Biomedizinische Technik\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1515/bmt-2021-0019\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/10/26 0:00:00\",\"PubModel\":\"Print\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Engineering / Biomedizinische Technik","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1515/bmt-2021-0019","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/10/26 0:00:00","PubModel":"Print","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 9

摘要

经颅磁刺激(TMS)具有广泛的临床应用,从诊断到治疗。我们将经颅磁刺激与经颅磁刺激诱发的外周肢体肌肉活动的非接触磁检测相结合,探索一种新的诊断方式,通过利用磁测技术的进步,增强经颅磁刺激作为临床工具的实用性。我们在一个普通的医院房间里使用一组光泵磁强计(opm)在一个便携式屏蔽内记录测量结果,该屏蔽只包裹受试者的前臂和手。我们展示了经颅磁刺激诱发的人手运动的磁肌图(MMG),以及同步的表面肌电图(EMG)数据。在MMG中记录的生物磁信号提供了详细的空间和时间信息,与电信号通道的信息互补。此外,我们在磁记录中发现了肌电图之外的特征。该系统展示了生物磁信号在基于tms的临床方法中的价值,并扩大了其可用性和实用潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Biomagnetic signals recorded during transcranial magnetic stimulation (TMS)-evoked peripheral muscular activity.

Transcranial magnetic stimulation (TMS) has widespread clinical applications from diagnosis to treatment. We combined TMS with non-contact magnetic detection of TMS-evoked muscle activity in peripheral limbs to explore a new diagnostic modality that enhances the utility of TMS as a clinical tool by leveraging technological advances in magnetometry. We recorded measurements in a regular hospital room using an array of optically pumped magnetometers (OPMs) inside a portable shield that encloses only the forearm and hand of the subject. We present magnetomyograms (MMG)s of TMS-evoked movement in a human hand, together with a simultaneous surface electromyograph (EMG) data. The biomagnetic signals recorded in the MMG provides detailed spatial and temporal information that is complementary to that of the electric signal channels. Moreover, we identify features in the magnetic recording beyond that of the EMG. This system demonstrates the value of biomagnetic signals in TMS-based clinical approaches and widens its availability and practical potential.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.50
自引率
5.90%
发文量
58
审稿时长
2-3 weeks
期刊介绍: Biomedical Engineering / Biomedizinische Technik (BMT) is a high-quality forum for the exchange of knowledge in the fields of biomedical engineering, medical information technology and biotechnology/bioengineering. As an established journal with a tradition of more than 60 years, BMT addresses engineers, natural scientists, and clinicians working in research, industry, or clinical practice.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信