{"title":"[通过移动应用程序:“轴移计”观察轴移机动的类内相关关系]。","authors":"I Ramos-Moctezuma,&nbsp;F Quintana-Trejo,&nbsp;L Sigala-González,&nbsp;I Leal-Berumen,&nbsp;E Cañedo,&nbsp;J Tonche-Ramos,&nbsp;O Carmona-Máynez,&nbsp;A Aguirre-Madrid,&nbsp;E Berumen-Nafarrate","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The anterior cruciate ligament is an anatomical structure that tends to cause problems for specialists when formulating an accurate diagnosis. There are measurement tools that support the diagnosis such as the KT1000; however, it still has some limitations, since it only manages to measure a single axis of movement, while the \"pivot-shift\" maneuver manages to capture more information about the state of the ligament, as it allows to evaluate the three axes of movement of the joint. The \"pivot-shift\" maneuver lacks a standard execution, therefore it can produce disagreement between evaluators; this creates the need for a tool capable of standardizing the maneuver, while providing an interpretable measurement.</p><p><strong>Material and methods: </strong>Pivot-shift meter application, a mobile software capable of capturing information on the movements made when executing a pivot maneuver. Intraclass correlation coefficient to measure the intra- and inter-observer correlation of the information captured by the application. The data was obtained from 66 random participants, using the mobile phone's built-in gyroscopes.</p><p><strong>Results: </strong>With the 66 tests carried out, it was observed that the evaluators tend to achieve high reproducibility when executing the maneuvers within the time period established by the application, which reached an intraclass correlation coefficient above 90%.</p><p><strong>Conclusion: </strong>The intra- and inter-observer correlation is high enough to be able to perform a quantitative analysis of the pivot-shift maneuver, through a mobile phone.</p>","PeriodicalId":7081,"journal":{"name":"Acta ortopedica mexicana","volume":"35 6","pages":"500-506"},"PeriodicalIF":0.0000,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Intraclass correlation intra- and inter-observer of the pivot-shift maneuver through mobile application: ''pivot-shift meter''].\",\"authors\":\"I Ramos-Moctezuma,&nbsp;F Quintana-Trejo,&nbsp;L Sigala-González,&nbsp;I Leal-Berumen,&nbsp;E Cañedo,&nbsp;J Tonche-Ramos,&nbsp;O Carmona-Máynez,&nbsp;A Aguirre-Madrid,&nbsp;E Berumen-Nafarrate\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>The anterior cruciate ligament is an anatomical structure that tends to cause problems for specialists when formulating an accurate diagnosis. There are measurement tools that support the diagnosis such as the KT1000; however, it still has some limitations, since it only manages to measure a single axis of movement, while the \\\"pivot-shift\\\" maneuver manages to capture more information about the state of the ligament, as it allows to evaluate the three axes of movement of the joint. The \\\"pivot-shift\\\" maneuver lacks a standard execution, therefore it can produce disagreement between evaluators; this creates the need for a tool capable of standardizing the maneuver, while providing an interpretable measurement.</p><p><strong>Material and methods: </strong>Pivot-shift meter application, a mobile software capable of capturing information on the movements made when executing a pivot maneuver. Intraclass correlation coefficient to measure the intra- and inter-observer correlation of the information captured by the application. The data was obtained from 66 random participants, using the mobile phone's built-in gyroscopes.</p><p><strong>Results: </strong>With the 66 tests carried out, it was observed that the evaluators tend to achieve high reproducibility when executing the maneuvers within the time period established by the application, which reached an intraclass correlation coefficient above 90%.</p><p><strong>Conclusion: </strong>The intra- and inter-observer correlation is high enough to be able to perform a quantitative analysis of the pivot-shift maneuver, through a mobile phone.</p>\",\"PeriodicalId\":7081,\"journal\":{\"name\":\"Acta ortopedica mexicana\",\"volume\":\"35 6\",\"pages\":\"500-506\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta ortopedica mexicana\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta ortopedica mexicana","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

前言:前交叉韧带是一种解剖结构,在制定准确诊断时往往会引起专家的问题。有支持诊断的测量工具,如KT1000;然而,它仍然有一些局限性,因为它只能测量单个运动轴,而“pivot-shift”操作可以捕获更多关于韧带状态的信息,因为它允许评估关节的三个运动轴。“支点转移”策略缺乏标准的执行,因此可能在评估者之间产生分歧;这就需要一种能够标准化操作的工具,同时提供可解释的测量。材料和方法:枢轴移动仪表应用程序,一种移动软件,能够捕获在执行枢轴机动时所做的运动的信息。类内相关系数用于测量应用程序捕获的信息的观察者内部和观察者之间的相关性。这些数据是通过手机内置的陀螺仪从66名随机参与者那里获得的。结果:通过66个测试,观察到评估者在应用程序设定的时间内执行操作时往往具有较高的重现性,其类内相关系数达到90%以上。结论:观察者内部和观察者之间的相关性足够高,可以通过手机对枢轴移位操作进行定量分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Intraclass correlation intra- and inter-observer of the pivot-shift maneuver through mobile application: ''pivot-shift meter''].

Introduction: The anterior cruciate ligament is an anatomical structure that tends to cause problems for specialists when formulating an accurate diagnosis. There are measurement tools that support the diagnosis such as the KT1000; however, it still has some limitations, since it only manages to measure a single axis of movement, while the "pivot-shift" maneuver manages to capture more information about the state of the ligament, as it allows to evaluate the three axes of movement of the joint. The "pivot-shift" maneuver lacks a standard execution, therefore it can produce disagreement between evaluators; this creates the need for a tool capable of standardizing the maneuver, while providing an interpretable measurement.

Material and methods: Pivot-shift meter application, a mobile software capable of capturing information on the movements made when executing a pivot maneuver. Intraclass correlation coefficient to measure the intra- and inter-observer correlation of the information captured by the application. The data was obtained from 66 random participants, using the mobile phone's built-in gyroscopes.

Results: With the 66 tests carried out, it was observed that the evaluators tend to achieve high reproducibility when executing the maneuvers within the time period established by the application, which reached an intraclass correlation coefficient above 90%.

Conclusion: The intra- and inter-observer correlation is high enough to be able to perform a quantitative analysis of the pivot-shift maneuver, through a mobile phone.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信