Florian Günther, Rainer H Straub, Wolfgang Hartung, Martin Fleck, Boris Ehrenstein, Louisa Schminke
{"title":"可溶性转铁蛋白受体在类风湿关节炎缺铁性贫血诊断中的临床应用","authors":"Florian Günther, Rainer H Straub, Wolfgang Hartung, Martin Fleck, Boris Ehrenstein, Louisa Schminke","doi":"10.1155/2022/7067262","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>We analyzed the added value of sTfR measurement in routine clinical practice to standard parameters (SP) of iron deficiency in the detection of iron deficiency anemia (IDA) in patients with rheumatoid arthritis (RA).</p><p><strong>Methods: </strong>Blood samples from 116 patients with RA were analyzed in a prospective study. Based on biochemical parameters, patients were classified as having IDA, anemia of chronic disease (ACD), IDA with concomitant ACD (ACD/IDA), or \"other anemia.\" Sensitivity, specificity, positive (PPV), and negative predictive values (NPV) of sTfR and SP of iron status alone and in combination were calculated for the diagnosis of IDA in general, i.e., IDA or ACD/IDA.</p><p><strong>Results: </strong>In the whole sample, with regard to the diagnosis of iron deficiency (IDA or ACD/IDA), sTfR had a higher sensitivity compared both to the combined use of SP and to the combination of SP with sTfR (80.9% versus 66.7/54.8%). Specificity, PPV and NPV did not differ substantially. When patients were stratified in groups with high (CRP levels above the median, i.e., 24.1 mg/l) and low (CRP levels less or equal to the median) inflammation, the diagnostic superiority of sTfR was restricted to patients with high inflammation. In this group, the diagnostic performance of sTfR was superior both to the combined use of SP and the combination of SP with sTfR with higher sensitivity (100% versus 52.4%) and NPV (100% versus 77.7/76.7%) and comparable specificity and PPV.</p><p><strong>Conclusion: </strong>For the detection of iron depletion (IDA or ACD/IDA) in anemic RA patients, sTfR is superior to SP of iron deficiency only in highly inflammatory states.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":" ","pages":"7067262"},"PeriodicalIF":4.6000,"publicationDate":"2022-10-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9581666/pdf/","citationCount":"1","resultStr":"{\"title\":\"Usefulness of Soluble Transferrin Receptor in the Diagnosis of Iron Deficiency Anemia in Rheumatoid Arthritis Patients in Clinical Practice.\",\"authors\":\"Florian Günther, Rainer H Straub, Wolfgang Hartung, Martin Fleck, Boris Ehrenstein, Louisa Schminke\",\"doi\":\"10.1155/2022/7067262\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aim: </strong>We analyzed the added value of sTfR measurement in routine clinical practice to standard parameters (SP) of iron deficiency in the detection of iron deficiency anemia (IDA) in patients with rheumatoid arthritis (RA).</p><p><strong>Methods: </strong>Blood samples from 116 patients with RA were analyzed in a prospective study. Based on biochemical parameters, patients were classified as having IDA, anemia of chronic disease (ACD), IDA with concomitant ACD (ACD/IDA), or \\\"other anemia.\\\" Sensitivity, specificity, positive (PPV), and negative predictive values (NPV) of sTfR and SP of iron status alone and in combination were calculated for the diagnosis of IDA in general, i.e., IDA or ACD/IDA.</p><p><strong>Results: </strong>In the whole sample, with regard to the diagnosis of iron deficiency (IDA or ACD/IDA), sTfR had a higher sensitivity compared both to the combined use of SP and to the combination of SP with sTfR (80.9% versus 66.7/54.8%). Specificity, PPV and NPV did not differ substantially. When patients were stratified in groups with high (CRP levels above the median, i.e., 24.1 mg/l) and low (CRP levels less or equal to the median) inflammation, the diagnostic superiority of sTfR was restricted to patients with high inflammation. In this group, the diagnostic performance of sTfR was superior both to the combined use of SP and the combination of SP with sTfR with higher sensitivity (100% versus 52.4%) and NPV (100% versus 77.7/76.7%) and comparable specificity and PPV.</p><p><strong>Conclusion: </strong>For the detection of iron depletion (IDA or ACD/IDA) in anemic RA patients, sTfR is superior to SP of iron deficiency only in highly inflammatory states.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":\" \",\"pages\":\"7067262\"},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2022-10-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9581666/pdf/\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/2022/7067262\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2022/7067262","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
Usefulness of Soluble Transferrin Receptor in the Diagnosis of Iron Deficiency Anemia in Rheumatoid Arthritis Patients in Clinical Practice.
Aim: We analyzed the added value of sTfR measurement in routine clinical practice to standard parameters (SP) of iron deficiency in the detection of iron deficiency anemia (IDA) in patients with rheumatoid arthritis (RA).
Methods: Blood samples from 116 patients with RA were analyzed in a prospective study. Based on biochemical parameters, patients were classified as having IDA, anemia of chronic disease (ACD), IDA with concomitant ACD (ACD/IDA), or "other anemia." Sensitivity, specificity, positive (PPV), and negative predictive values (NPV) of sTfR and SP of iron status alone and in combination were calculated for the diagnosis of IDA in general, i.e., IDA or ACD/IDA.
Results: In the whole sample, with regard to the diagnosis of iron deficiency (IDA or ACD/IDA), sTfR had a higher sensitivity compared both to the combined use of SP and to the combination of SP with sTfR (80.9% versus 66.7/54.8%). Specificity, PPV and NPV did not differ substantially. When patients were stratified in groups with high (CRP levels above the median, i.e., 24.1 mg/l) and low (CRP levels less or equal to the median) inflammation, the diagnostic superiority of sTfR was restricted to patients with high inflammation. In this group, the diagnostic performance of sTfR was superior both to the combined use of SP and the combination of SP with sTfR with higher sensitivity (100% versus 52.4%) and NPV (100% versus 77.7/76.7%) and comparable specificity and PPV.
Conclusion: For the detection of iron depletion (IDA or ACD/IDA) in anemic RA patients, sTfR is superior to SP of iron deficiency only in highly inflammatory states.
期刊介绍:
ACS Applied Bio Materials is an interdisciplinary journal publishing original research covering all aspects of biomaterials and biointerfaces including and beyond the traditional biosensing, biomedical and therapeutic applications.
The journal is devoted to reports of new and original experimental and theoretical research of an applied nature that integrates knowledge in the areas of materials, engineering, physics, bioscience, and chemistry into important bio applications. The journal is specifically interested in work that addresses the relationship between structure and function and assesses the stability and degradation of materials under relevant environmental and biological conditions.