Bob Buzas, Julie Smith, Gregory E Gilbert, Nancy Moureau
{"title":"使用抗反流无针连接器的中心静脉通路装置的家庭输液药房质量改进,以减少闭塞,急诊室就诊和阿替普酶成本。","authors":"Bob Buzas, Julie Smith, Gregory E Gilbert, Nancy Moureau","doi":"10.1093/ajhp/zxac083","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The study's purpose was to measure the impact of anti-reflux needleless connector usage in prevention of intraluminal thrombotic occlusions among central venous catheters, as represented by alteplase usage, in a home infusion patient population.</p><p><strong>Methods: </strong>An18-month before-and-after cohort study of a single home infusion intervention was conducted to compare occlusion outcomes with use of two types of needleless connectors-neutral and anti-reflux-in preventing catheter occlusions, which have been reported to occur in 28% of home infusion patients, resulting in treatment delays, increased nursing encounters and emergency room visits, and higher overall pharmacy costs for supplies and alteplase.</p><p><strong>Results: </strong>A total of 552,707 patient therapy days were studied: 42.5% in the neutral needleless connector group (n = 235,004 therapy days) and 57.5% in the anti-reflux needleless connector group (n = 317,703 therapy days). The rate of alteplase usage with neutral versus anti-reflux needleless connectors was 4.4% versus 2.2% per 1,000 therapy days, with median alteplase use of 112 (95% CI, 89-169) units versus 82 (95% CI, 68-109) units (P < 0.001). Implementation of anti-reflux connectors reduced occlusions and alteplase usage by 48%.</p><p><strong>Conclusion: </strong>Statistical evidence demonstrated that use of anti-reflux needleless connectors with central venous access devices reduced the need for alteplase in the study population. Since 10% of patient occlusions were within 7 days after home infusion admission, future research may indicate that placement of anti-reflux needleless connectors at the time of in-hospital insertion can improve patient outcomes. This quality improvement measure reduced central catheter occlusions, alteplase costs, and the number of required nursing and emergency room visits.</p>","PeriodicalId":520552,"journal":{"name":"American journal of health-system pharmacy : AJHP : official journal of the American Society of Health-System Pharmacists","volume":" ","pages":"1079-1085"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Home infusion pharmacy quality improvement for central venous access devices using anti-reflux needleless connectors to reduce occlusions, emergency room visits, and alteplase costs.\",\"authors\":\"Bob Buzas, Julie Smith, Gregory E Gilbert, Nancy Moureau\",\"doi\":\"10.1093/ajhp/zxac083\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The study's purpose was to measure the impact of anti-reflux needleless connector usage in prevention of intraluminal thrombotic occlusions among central venous catheters, as represented by alteplase usage, in a home infusion patient population.</p><p><strong>Methods: </strong>An18-month before-and-after cohort study of a single home infusion intervention was conducted to compare occlusion outcomes with use of two types of needleless connectors-neutral and anti-reflux-in preventing catheter occlusions, which have been reported to occur in 28% of home infusion patients, resulting in treatment delays, increased nursing encounters and emergency room visits, and higher overall pharmacy costs for supplies and alteplase.</p><p><strong>Results: </strong>A total of 552,707 patient therapy days were studied: 42.5% in the neutral needleless connector group (n = 235,004 therapy days) and 57.5% in the anti-reflux needleless connector group (n = 317,703 therapy days). The rate of alteplase usage with neutral versus anti-reflux needleless connectors was 4.4% versus 2.2% per 1,000 therapy days, with median alteplase use of 112 (95% CI, 89-169) units versus 82 (95% CI, 68-109) units (P < 0.001). Implementation of anti-reflux connectors reduced occlusions and alteplase usage by 48%.</p><p><strong>Conclusion: </strong>Statistical evidence demonstrated that use of anti-reflux needleless connectors with central venous access devices reduced the need for alteplase in the study population. Since 10% of patient occlusions were within 7 days after home infusion admission, future research may indicate that placement of anti-reflux needleless connectors at the time of in-hospital insertion can improve patient outcomes. This quality improvement measure reduced central catheter occlusions, alteplase costs, and the number of required nursing and emergency room visits.</p>\",\"PeriodicalId\":520552,\"journal\":{\"name\":\"American journal of health-system pharmacy : AJHP : official journal of the American Society of Health-System Pharmacists\",\"volume\":\" \",\"pages\":\"1079-1085\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-06-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American journal of health-system pharmacy : AJHP : official journal of the American Society of Health-System Pharmacists\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1093/ajhp/zxac083\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of health-system pharmacy : AJHP : official journal of the American Society of Health-System Pharmacists","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/ajhp/zxac083","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Home infusion pharmacy quality improvement for central venous access devices using anti-reflux needleless connectors to reduce occlusions, emergency room visits, and alteplase costs.
Purpose: The study's purpose was to measure the impact of anti-reflux needleless connector usage in prevention of intraluminal thrombotic occlusions among central venous catheters, as represented by alteplase usage, in a home infusion patient population.
Methods: An18-month before-and-after cohort study of a single home infusion intervention was conducted to compare occlusion outcomes with use of two types of needleless connectors-neutral and anti-reflux-in preventing catheter occlusions, which have been reported to occur in 28% of home infusion patients, resulting in treatment delays, increased nursing encounters and emergency room visits, and higher overall pharmacy costs for supplies and alteplase.
Results: A total of 552,707 patient therapy days were studied: 42.5% in the neutral needleless connector group (n = 235,004 therapy days) and 57.5% in the anti-reflux needleless connector group (n = 317,703 therapy days). The rate of alteplase usage with neutral versus anti-reflux needleless connectors was 4.4% versus 2.2% per 1,000 therapy days, with median alteplase use of 112 (95% CI, 89-169) units versus 82 (95% CI, 68-109) units (P < 0.001). Implementation of anti-reflux connectors reduced occlusions and alteplase usage by 48%.
Conclusion: Statistical evidence demonstrated that use of anti-reflux needleless connectors with central venous access devices reduced the need for alteplase in the study population. Since 10% of patient occlusions were within 7 days after home infusion admission, future research may indicate that placement of anti-reflux needleless connectors at the time of in-hospital insertion can improve patient outcomes. This quality improvement measure reduced central catheter occlusions, alteplase costs, and the number of required nursing and emergency room visits.