{"title":"快速稳定指示反相高效液相色谱法测定盐酸倍他洛尔片的含量。","authors":"Sylvain Auvity, Fouad Chiadmi, Salvatore Cisternino, Jean-Eudes Fontan, Joël Schlatter","doi":"10.4137/ACI.S11256","DOIUrl":null,"url":null,"abstract":"<p><p>A stability-indicating reversed-phase high performance liquid chromatography (RP-HPLC) method was developed for the determination of betaxolol hydrochloride, a drug used in the treatment of hypertension and glaucoma. The desired chromatographic separation was achieved on a Nucleosil C18, 4 μm (150 × 4.6 mm) column, using isocratic elution at a 220 nm detector wavelength. The optimized mobile phase consisted of a 0.02 M potassium dihydrogen phosphate: methanol (40:60, v/v, pH 3.0 adjusted with o- phosphoric acid) as solvent. The flow rate was 1.6 mL/min and the retention time of betaxolol hydrochloride was 1.72 min. The linearity for betaxolol hydrochloride was in the range of 25 to 200 μg/mL. Recovery for betaxolol hydrochloride was calculated as 100.01%-101.35%. The stability-indicating capability was established by forced degradation experiments and the separation of unknown degradation products. The developed RP-HPLC method was validated according to the International Conference on Harmonization (ICH) guidelines. This validated method was applied for the estimation of betaxolol hydrochloride in commercially available tablets.</p>","PeriodicalId":7781,"journal":{"name":"Analytical Chemistry Insights","volume":" ","pages":"1-7"},"PeriodicalIF":0.0000,"publicationDate":"2013-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.4137/ACI.S11256","citationCount":"4","resultStr":"{\"title\":\"A Rapid Stability-Indicating RP-HPLC Method for the Determination of Betaxolol Hydrochloride in Pharmaceutical Tablets.\",\"authors\":\"Sylvain Auvity, Fouad Chiadmi, Salvatore Cisternino, Jean-Eudes Fontan, Joël Schlatter\",\"doi\":\"10.4137/ACI.S11256\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A stability-indicating reversed-phase high performance liquid chromatography (RP-HPLC) method was developed for the determination of betaxolol hydrochloride, a drug used in the treatment of hypertension and glaucoma. The desired chromatographic separation was achieved on a Nucleosil C18, 4 μm (150 × 4.6 mm) column, using isocratic elution at a 220 nm detector wavelength. The optimized mobile phase consisted of a 0.02 M potassium dihydrogen phosphate: methanol (40:60, v/v, pH 3.0 adjusted with o- phosphoric acid) as solvent. The flow rate was 1.6 mL/min and the retention time of betaxolol hydrochloride was 1.72 min. The linearity for betaxolol hydrochloride was in the range of 25 to 200 μg/mL. Recovery for betaxolol hydrochloride was calculated as 100.01%-101.35%. The stability-indicating capability was established by forced degradation experiments and the separation of unknown degradation products. The developed RP-HPLC method was validated according to the International Conference on Harmonization (ICH) guidelines. This validated method was applied for the estimation of betaxolol hydrochloride in commercially available tablets.</p>\",\"PeriodicalId\":7781,\"journal\":{\"name\":\"Analytical Chemistry Insights\",\"volume\":\" \",\"pages\":\"1-7\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.4137/ACI.S11256\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytical Chemistry Insights\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4137/ACI.S11256\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2013/3/11 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Chemistry Insights","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4137/ACI.S11256","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2013/3/11 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
A Rapid Stability-Indicating RP-HPLC Method for the Determination of Betaxolol Hydrochloride in Pharmaceutical Tablets.
A stability-indicating reversed-phase high performance liquid chromatography (RP-HPLC) method was developed for the determination of betaxolol hydrochloride, a drug used in the treatment of hypertension and glaucoma. The desired chromatographic separation was achieved on a Nucleosil C18, 4 μm (150 × 4.6 mm) column, using isocratic elution at a 220 nm detector wavelength. The optimized mobile phase consisted of a 0.02 M potassium dihydrogen phosphate: methanol (40:60, v/v, pH 3.0 adjusted with o- phosphoric acid) as solvent. The flow rate was 1.6 mL/min and the retention time of betaxolol hydrochloride was 1.72 min. The linearity for betaxolol hydrochloride was in the range of 25 to 200 μg/mL. Recovery for betaxolol hydrochloride was calculated as 100.01%-101.35%. The stability-indicating capability was established by forced degradation experiments and the separation of unknown degradation products. The developed RP-HPLC method was validated according to the International Conference on Harmonization (ICH) guidelines. This validated method was applied for the estimation of betaxolol hydrochloride in commercially available tablets.