Yalçın Gökoğlan, Sait Demirkol, Ibrahim Halil Kurt, Oben Baysan, Serdar Fırtına, Barış Bugan, Hürkan Kurşaklıoğlu
{"title":"三维TEE引导下Amplatzer导管闭塞器经皮有效封堵重度主动脉瓣旁漏。","authors":"Yalçın Gökoğlan, Sait Demirkol, Ibrahim Halil Kurt, Oben Baysan, Serdar Fırtına, Barış Bugan, Hürkan Kurşaklıoğlu","doi":"10.5152/akd.2012.046","DOIUrl":null,"url":null,"abstract":"Aortic paravalvular leaks are well-known complications of prosthetic valve replacement. They are asymptomatic and small, but sometimes may cause symptoms due to severe regurgitation or hemolysis. Medical therapy is limited, while operation causes significant mortality. Percutaneous transcatheter closure techniques, potentially offer symptomatic relief. We describe the use of an Amplatzer duct occluder device with the guidance of 3dimensional transesophageal echocardiography (3DTEE) in a patient with severe aortic prosthetic paravalvular leak resulting in effective closure.","PeriodicalId":55524,"journal":{"name":"Anadolu Kardiyoloji Dergisi-The Anatolian Journal of Cardiology","volume":" ","pages":"181-2"},"PeriodicalIF":0.0000,"publicationDate":"2012-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Percutaneous effective closure of severe aortic prosthetic paravalvular leak using Amplatzer duct occluder device with the guidance of 3D TEE.\",\"authors\":\"Yalçın Gökoğlan, Sait Demirkol, Ibrahim Halil Kurt, Oben Baysan, Serdar Fırtına, Barış Bugan, Hürkan Kurşaklıoğlu\",\"doi\":\"10.5152/akd.2012.046\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Aortic paravalvular leaks are well-known complications of prosthetic valve replacement. They are asymptomatic and small, but sometimes may cause symptoms due to severe regurgitation or hemolysis. Medical therapy is limited, while operation causes significant mortality. Percutaneous transcatheter closure techniques, potentially offer symptomatic relief. We describe the use of an Amplatzer duct occluder device with the guidance of 3dimensional transesophageal echocardiography (3DTEE) in a patient with severe aortic prosthetic paravalvular leak resulting in effective closure.\",\"PeriodicalId\":55524,\"journal\":{\"name\":\"Anadolu Kardiyoloji Dergisi-The Anatolian Journal of Cardiology\",\"volume\":\" \",\"pages\":\"181-2\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Anadolu Kardiyoloji Dergisi-The Anatolian Journal of Cardiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5152/akd.2012.046\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2012/2/7 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anadolu Kardiyoloji Dergisi-The Anatolian Journal of Cardiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5152/akd.2012.046","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2012/2/7 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
Percutaneous effective closure of severe aortic prosthetic paravalvular leak using Amplatzer duct occluder device with the guidance of 3D TEE.
Aortic paravalvular leaks are well-known complications of prosthetic valve replacement. They are asymptomatic and small, but sometimes may cause symptoms due to severe regurgitation or hemolysis. Medical therapy is limited, while operation causes significant mortality. Percutaneous transcatheter closure techniques, potentially offer symptomatic relief. We describe the use of an Amplatzer duct occluder device with the guidance of 3dimensional transesophageal echocardiography (3DTEE) in a patient with severe aortic prosthetic paravalvular leak resulting in effective closure.