{"title":"肺静脉隔离房颤后隆突内再入性房性心动过速。","authors":"Kohki Nakamura, Takehito Sasaki, Wataru Sasaki, Yumiko Haraguchi, Koki Kimura, Shigeto Naito","doi":"10.1111/pace.14440","DOIUrl":null,"url":null,"abstract":"<p><p>A 77-year-old man underwent catheter ablation of an atrial tachycardia (AT) after a pulmonary vein (PV) isolation of atrial fibrillation. The AT appeared to be a figure-of-eight reentrant AT by high-resolution mapping: one reentrant circuit rotated clockwise within the right PV (RPV) carina and the other rotated counterclockwise via two conduction gaps along the previous RPV isolation line. However, entrainment pacing from the carina and conduction gaps suggested that the AT was an intra-carina localized reentrant AT with a passive loop around the anterior RPV isolation line via those gaps. A radiofrequency application at the RPV carina terminated the AT.</p>","PeriodicalId":520740,"journal":{"name":"Pacing and clinical electrophysiology : PACE","volume":" ","pages":"700-702"},"PeriodicalIF":1.3000,"publicationDate":"2022-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Intra-carina reentrant atrial tachycardia after pulmonary vein isolation of atrial fibrillation.\",\"authors\":\"Kohki Nakamura, Takehito Sasaki, Wataru Sasaki, Yumiko Haraguchi, Koki Kimura, Shigeto Naito\",\"doi\":\"10.1111/pace.14440\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A 77-year-old man underwent catheter ablation of an atrial tachycardia (AT) after a pulmonary vein (PV) isolation of atrial fibrillation. The AT appeared to be a figure-of-eight reentrant AT by high-resolution mapping: one reentrant circuit rotated clockwise within the right PV (RPV) carina and the other rotated counterclockwise via two conduction gaps along the previous RPV isolation line. However, entrainment pacing from the carina and conduction gaps suggested that the AT was an intra-carina localized reentrant AT with a passive loop around the anterior RPV isolation line via those gaps. A radiofrequency application at the RPV carina terminated the AT.</p>\",\"PeriodicalId\":520740,\"journal\":{\"name\":\"Pacing and clinical electrophysiology : PACE\",\"volume\":\" \",\"pages\":\"700-702\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2022-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pacing and clinical electrophysiology : PACE\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1111/pace.14440\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/1/17 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pacing and clinical electrophysiology : PACE","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1111/pace.14440","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/17 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
Intra-carina reentrant atrial tachycardia after pulmonary vein isolation of atrial fibrillation.
A 77-year-old man underwent catheter ablation of an atrial tachycardia (AT) after a pulmonary vein (PV) isolation of atrial fibrillation. The AT appeared to be a figure-of-eight reentrant AT by high-resolution mapping: one reentrant circuit rotated clockwise within the right PV (RPV) carina and the other rotated counterclockwise via two conduction gaps along the previous RPV isolation line. However, entrainment pacing from the carina and conduction gaps suggested that the AT was an intra-carina localized reentrant AT with a passive loop around the anterior RPV isolation line via those gaps. A radiofrequency application at the RPV carina terminated the AT.