改进血浆microRNA提取和商用试剂盒比较的方案。

IF 3.8 3区 医学 Q1 MEDICAL LABORATORY TECHNOLOGY
Harshini Sriram, Twinkle Khanka, Shweta Kedia, Priyanka Tyagi, Sitaram Ghogale, Nilesh Deshpande, Gaurav Chatterjee, Sweta Rajpal, Nikhil V Patkar, Papagudi G Subramanian, Sumeet Gujral, Syed Hasan, Prashant R Tembhare
{"title":"改进血浆microRNA提取和商用试剂盒比较的方案。","authors":"Harshini Sriram,&nbsp;Twinkle Khanka,&nbsp;Shweta Kedia,&nbsp;Priyanka Tyagi,&nbsp;Sitaram Ghogale,&nbsp;Nilesh Deshpande,&nbsp;Gaurav Chatterjee,&nbsp;Sweta Rajpal,&nbsp;Nikhil V Patkar,&nbsp;Papagudi G Subramanian,&nbsp;Sumeet Gujral,&nbsp;Syed Hasan,&nbsp;Prashant R Tembhare","doi":"10.11613/BM.2021.030705","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>MicroRNAs are small, non-coding RNA molecules that are becoming popular biomarkers in several diseases. However, their low abundance in serum/plasma poses a challenge in exploiting their potential in clinics. Several commercial kits are available for rapid isolation of microRNA from plasma. However, reports guiding the selection of appropriate kits to study downstream assays are scarce. Hence, we compared four commercial kits to evaluate microRNA-extraction from plasma and provided a modified protocol that further improved the superior kit's performance.</p><p><strong>Materials and methods: </strong>We compared four kits (miRNeasy Serum/Plasma, miRNeasy Mini Kit from Qiagen; RNA-isolation, and Absolutely-RNA MicroRNA Kit from Agilent technologies) for quality and quantity of microRNA isolated, extraction efficiency, and cost-effectiveness. Bioanalyzer-based Agilent Small RNA kit was used to evaluate quality and quantity of microRNA. Extraction efficiency was evaluated by detection of four endogenous control microRNA using real-time-PCR. Further, we modified the manufacturer's protocol for miRNeasy Serum/Plasma kit to improve yield.</p><p><strong>Results: </strong>miRNeasy Serum/Plasma kit outperformed the other three kits in microRNA-quality (P < 0.005) and yielded maximum microRNA-quantity. Recovery of endogenous control microRNA <i>i.e.</i> hsa-miR-24-3p, hsa-miR-191-5p, hsa-miR-423-5p and hsa-miR-484 was higher as well. Modification with the inclusion of a double elution step enhanced yield of microRNA extracted with miRNeasy Serum/Plasma kit significantly (P < 0.001).</p><p><strong>Conclusion: </strong>We demonstrated that miRNeasy Serum/Plasma kit outperforms other kits and can be reliably used with a limited plasma quantity. We have provided a modified microRNA-extraction protocol with improved microRNA output for downstream analyses.</p>","PeriodicalId":9021,"journal":{"name":"Biochemia Medica","volume":"31 3","pages":"030705"},"PeriodicalIF":3.8000,"publicationDate":"2021-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8495618/pdf/","citationCount":"5","resultStr":"{\"title\":\"Improved protocol for plasma microRNA extraction and comparison of commercial kits.\",\"authors\":\"Harshini Sriram,&nbsp;Twinkle Khanka,&nbsp;Shweta Kedia,&nbsp;Priyanka Tyagi,&nbsp;Sitaram Ghogale,&nbsp;Nilesh Deshpande,&nbsp;Gaurav Chatterjee,&nbsp;Sweta Rajpal,&nbsp;Nikhil V Patkar,&nbsp;Papagudi G Subramanian,&nbsp;Sumeet Gujral,&nbsp;Syed Hasan,&nbsp;Prashant R Tembhare\",\"doi\":\"10.11613/BM.2021.030705\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>MicroRNAs are small, non-coding RNA molecules that are becoming popular biomarkers in several diseases. However, their low abundance in serum/plasma poses a challenge in exploiting their potential in clinics. Several commercial kits are available for rapid isolation of microRNA from plasma. However, reports guiding the selection of appropriate kits to study downstream assays are scarce. Hence, we compared four commercial kits to evaluate microRNA-extraction from plasma and provided a modified protocol that further improved the superior kit's performance.</p><p><strong>Materials and methods: </strong>We compared four kits (miRNeasy Serum/Plasma, miRNeasy Mini Kit from Qiagen; RNA-isolation, and Absolutely-RNA MicroRNA Kit from Agilent technologies) for quality and quantity of microRNA isolated, extraction efficiency, and cost-effectiveness. Bioanalyzer-based Agilent Small RNA kit was used to evaluate quality and quantity of microRNA. Extraction efficiency was evaluated by detection of four endogenous control microRNA using real-time-PCR. Further, we modified the manufacturer's protocol for miRNeasy Serum/Plasma kit to improve yield.</p><p><strong>Results: </strong>miRNeasy Serum/Plasma kit outperformed the other three kits in microRNA-quality (P < 0.005) and yielded maximum microRNA-quantity. Recovery of endogenous control microRNA <i>i.e.</i> hsa-miR-24-3p, hsa-miR-191-5p, hsa-miR-423-5p and hsa-miR-484 was higher as well. Modification with the inclusion of a double elution step enhanced yield of microRNA extracted with miRNeasy Serum/Plasma kit significantly (P < 0.001).</p><p><strong>Conclusion: </strong>We demonstrated that miRNeasy Serum/Plasma kit outperforms other kits and can be reliably used with a limited plasma quantity. We have provided a modified microRNA-extraction protocol with improved microRNA output for downstream analyses.</p>\",\"PeriodicalId\":9021,\"journal\":{\"name\":\"Biochemia Medica\",\"volume\":\"31 3\",\"pages\":\"030705\"},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2021-10-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8495618/pdf/\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biochemia Medica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.11613/BM.2021.030705\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biochemia Medica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11613/BM.2021.030705","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 5

摘要

MicroRNAs是一种小的、非编码的RNA分子,正在成为几种疾病中流行的生物标志物。然而,它们在血清/血浆中的低丰度对其临床应用潜力提出了挑战。有几种商用试剂盒可用于从血浆中快速分离microRNA。然而,指导选择合适的试剂盒来研究下游检测的报告很少。因此,我们比较了四种商业试剂盒来评估从血浆中提取microrna,并提供了一种改进的方案,进一步提高了优越试剂盒的性能。材料和方法:我们比较了四种试剂盒(miRNeasy Serum/Plasma, miRNeasy Mini Kit from Qiagen;rna分离和绝对rna MicroRNA Kit(来自Agilent technologies),用于分离的MicroRNA的质量和数量,提取效率和成本效益。使用基于生物分析仪的Agilent小RNA试剂盒评估microRNA的质量和数量。采用real-time-PCR检测4种内源性对照microRNA,评价提取效率。此外,我们修改了miRNeasy血清/血浆试剂盒的制造商协议,以提高产量。结果:miRNeasy血清/血浆试剂盒在microrna质量上优于其他3种试剂盒(P < 0.005),且microrna含量最高。内源性对照microRNA,即hsa-miR-24-3p、hsa-miR-191-5p、hsa-miR-423-5p和hsa-miR-484的回收率也较高。加入双洗脱步骤的修饰显著提高了miRNeasy血清/血浆试剂盒提取的microRNA的产量(P < 0.001)。结论:我们证明miRNeasy血清/血浆试剂盒优于其他试剂盒,可以可靠地用于有限的血浆量。我们提供了一种改进的microRNA提取方案,改善了下游分析的microRNA输出。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Improved protocol for plasma microRNA extraction and comparison of commercial kits.

Improved protocol for plasma microRNA extraction and comparison of commercial kits.

Introduction: MicroRNAs are small, non-coding RNA molecules that are becoming popular biomarkers in several diseases. However, their low abundance in serum/plasma poses a challenge in exploiting their potential in clinics. Several commercial kits are available for rapid isolation of microRNA from plasma. However, reports guiding the selection of appropriate kits to study downstream assays are scarce. Hence, we compared four commercial kits to evaluate microRNA-extraction from plasma and provided a modified protocol that further improved the superior kit's performance.

Materials and methods: We compared four kits (miRNeasy Serum/Plasma, miRNeasy Mini Kit from Qiagen; RNA-isolation, and Absolutely-RNA MicroRNA Kit from Agilent technologies) for quality and quantity of microRNA isolated, extraction efficiency, and cost-effectiveness. Bioanalyzer-based Agilent Small RNA kit was used to evaluate quality and quantity of microRNA. Extraction efficiency was evaluated by detection of four endogenous control microRNA using real-time-PCR. Further, we modified the manufacturer's protocol for miRNeasy Serum/Plasma kit to improve yield.

Results: miRNeasy Serum/Plasma kit outperformed the other three kits in microRNA-quality (P < 0.005) and yielded maximum microRNA-quantity. Recovery of endogenous control microRNA i.e. hsa-miR-24-3p, hsa-miR-191-5p, hsa-miR-423-5p and hsa-miR-484 was higher as well. Modification with the inclusion of a double elution step enhanced yield of microRNA extracted with miRNeasy Serum/Plasma kit significantly (P < 0.001).

Conclusion: We demonstrated that miRNeasy Serum/Plasma kit outperforms other kits and can be reliably used with a limited plasma quantity. We have provided a modified microRNA-extraction protocol with improved microRNA output for downstream analyses.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Biochemia Medica
Biochemia Medica 医学-医学实验技术
CiteScore
5.50
自引率
3.00%
发文量
70
审稿时长
>12 weeks
期刊介绍: Biochemia Medica is the official peer-reviewed journal of the Croatian Society of Medical Biochemistry and Laboratory Medicine. Journal provides a wide coverage of research in all aspects of clinical chemistry and laboratory medicine. Following categories fit into the scope of the Journal: general clinical chemistry, haematology and haemostasis, molecular diagnostics and endocrinology. Development, validation and verification of analytical techniques and methods applicable to clinical chemistry and laboratory medicine are welcome as well as studies dealing with laboratory organization, automation and quality control. Journal publishes on a regular basis educative preanalytical case reports (Preanalytical mysteries), articles dealing with applied biostatistics (Lessons in biostatistics) and research integrity (Research integrity corner).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信