Brian McEvoy, Stacy Bohl Wiehle, Ken Gordon, Gerry Kearns, Paulo Laranjeira, Nicole McLees
{"title":"通过工艺验证推进环氧乙烷的可持续利用。","authors":"Brian McEvoy, Stacy Bohl Wiehle, Ken Gordon, Gerry Kearns, Paulo Laranjeira, Nicole McLees","doi":"10.2345/0899-8205-55.s3.35","DOIUrl":null,"url":null,"abstract":"<p><p>Based on excellent material compatibility and ability for scale, ethylene oxide (EO) sterilization constitutes approximately 50% of single-use medical device sterilization globally. Epidemiological considerations have elevated focus toward optimization of EO processes, whereby only necessary amounts of sterilant are used in routine processing. EO sterilization of medical devices is validated in accordance with AAMI/ANSI/ISO 11135:2014 via a manner in which a sterility assurance level (SAL) of 10-6 is typically achieved, with multiple layers of conservativeness delivered, using \"overkill\" approaches to validation. Various optimization strategies are being used throughout the medical device industry to deliver the required SAL while utilizing only necessary amounts of sterilant. This article presents relevant experiences and describes challenges and considerations encountered in delivering EO process optimization. Thus far, the results observed by the authors are encouraging in demonstrating how EO processing can be optimized in the delivery of critical single-use medical devices for patient care.</p>","PeriodicalId":35656,"journal":{"name":"Biomedical Instrumentation and Technology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8655701/pdf/i0899-8205-55-s3-35.pdf","citationCount":"3","resultStr":"{\"title\":\"Advancing the Sustainable Use of Ethylene Oxide through Process Validation.\",\"authors\":\"Brian McEvoy, Stacy Bohl Wiehle, Ken Gordon, Gerry Kearns, Paulo Laranjeira, Nicole McLees\",\"doi\":\"10.2345/0899-8205-55.s3.35\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Based on excellent material compatibility and ability for scale, ethylene oxide (EO) sterilization constitutes approximately 50% of single-use medical device sterilization globally. Epidemiological considerations have elevated focus toward optimization of EO processes, whereby only necessary amounts of sterilant are used in routine processing. EO sterilization of medical devices is validated in accordance with AAMI/ANSI/ISO 11135:2014 via a manner in which a sterility assurance level (SAL) of 10-6 is typically achieved, with multiple layers of conservativeness delivered, using \\\"overkill\\\" approaches to validation. Various optimization strategies are being used throughout the medical device industry to deliver the required SAL while utilizing only necessary amounts of sterilant. This article presents relevant experiences and describes challenges and considerations encountered in delivering EO process optimization. Thus far, the results observed by the authors are encouraging in demonstrating how EO processing can be optimized in the delivery of critical single-use medical devices for patient care.</p>\",\"PeriodicalId\":35656,\"journal\":{\"name\":\"Biomedical Instrumentation and Technology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8655701/pdf/i0899-8205-55-s3-35.pdf\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomedical Instrumentation and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2345/0899-8205-55.s3.35\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Instrumentation and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2345/0899-8205-55.s3.35","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
Advancing the Sustainable Use of Ethylene Oxide through Process Validation.
Based on excellent material compatibility and ability for scale, ethylene oxide (EO) sterilization constitutes approximately 50% of single-use medical device sterilization globally. Epidemiological considerations have elevated focus toward optimization of EO processes, whereby only necessary amounts of sterilant are used in routine processing. EO sterilization of medical devices is validated in accordance with AAMI/ANSI/ISO 11135:2014 via a manner in which a sterility assurance level (SAL) of 10-6 is typically achieved, with multiple layers of conservativeness delivered, using "overkill" approaches to validation. Various optimization strategies are being used throughout the medical device industry to deliver the required SAL while utilizing only necessary amounts of sterilant. This article presents relevant experiences and describes challenges and considerations encountered in delivering EO process optimization. Thus far, the results observed by the authors are encouraging in demonstrating how EO processing can be optimized in the delivery of critical single-use medical devices for patient care.
期刊介绍:
AAMI publishes Biomedical Instrumentation & Technology (BI&T) a bi-monthly peer-reviewed journal dedicated to the developers, managers, and users of medical instrumentation and technology.