{"title":"利用时程和校准数据估计浓度响应函数和变点。","authors":"B Qiang, A Abdalla, S Morgan, P Hashemi, E Peña","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>In this paper the problem of determining the functional relationship between time and the concentration of a chemical substance is studied. An intervention drug is administered on the experimental unit from which the chemical substance (specimen) is measured. This drug is hypothesized to cause a change in the concentration level of the chemical substance a certain lag-time after the intervention. However, the concentration value could not be directly measured, but rather a surrogate response can be measured. In the time-course study, this surrogate response is measured using different electrodes which possess varied behaviors. To utilize these surrogate measurements arising from the different electrodes (sensors), a calibration study is undertaken which measures the surrogate response for the different electrodes at known concentration levels. Based on the time-course and calibration data sets, a statistical procedure to estimate the signal function and the lag-time is proposed. Simulation studies indicate that the proposed procedure is able to reasonably recover the signal function and the lag-time. The procedure is then applied to the real data sets obtained during an analytical chemistry experiment.</p>","PeriodicalId":72412,"journal":{"name":"Biostatistics and biometrics open access journal","volume":"9 3","pages":"57-68"},"PeriodicalIF":0.0000,"publicationDate":"2019-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8189314/pdf/","citationCount":"0","resultStr":"{\"title\":\"Estimating Concentration Response Function and Change-Point using Time-Course and Calibration Data.\",\"authors\":\"B Qiang, A Abdalla, S Morgan, P Hashemi, E Peña\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In this paper the problem of determining the functional relationship between time and the concentration of a chemical substance is studied. An intervention drug is administered on the experimental unit from which the chemical substance (specimen) is measured. This drug is hypothesized to cause a change in the concentration level of the chemical substance a certain lag-time after the intervention. However, the concentration value could not be directly measured, but rather a surrogate response can be measured. In the time-course study, this surrogate response is measured using different electrodes which possess varied behaviors. To utilize these surrogate measurements arising from the different electrodes (sensors), a calibration study is undertaken which measures the surrogate response for the different electrodes at known concentration levels. Based on the time-course and calibration data sets, a statistical procedure to estimate the signal function and the lag-time is proposed. Simulation studies indicate that the proposed procedure is able to reasonably recover the signal function and the lag-time. The procedure is then applied to the real data sets obtained during an analytical chemistry experiment.</p>\",\"PeriodicalId\":72412,\"journal\":{\"name\":\"Biostatistics and biometrics open access journal\",\"volume\":\"9 3\",\"pages\":\"57-68\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8189314/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biostatistics and biometrics open access journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2019/3/18 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biostatistics and biometrics open access journal","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2019/3/18 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
Estimating Concentration Response Function and Change-Point using Time-Course and Calibration Data.
In this paper the problem of determining the functional relationship between time and the concentration of a chemical substance is studied. An intervention drug is administered on the experimental unit from which the chemical substance (specimen) is measured. This drug is hypothesized to cause a change in the concentration level of the chemical substance a certain lag-time after the intervention. However, the concentration value could not be directly measured, but rather a surrogate response can be measured. In the time-course study, this surrogate response is measured using different electrodes which possess varied behaviors. To utilize these surrogate measurements arising from the different electrodes (sensors), a calibration study is undertaken which measures the surrogate response for the different electrodes at known concentration levels. Based on the time-course and calibration data sets, a statistical procedure to estimate the signal function and the lag-time is proposed. Simulation studies indicate that the proposed procedure is able to reasonably recover the signal function and the lag-time. The procedure is then applied to the real data sets obtained during an analytical chemistry experiment.