Pierre Laumonerie, Meagan E Tibbo, Gregoire Laumond, Dominique Barbier, Pauline Assemat, Pascal Swider, Franck Accadbled
{"title":"在前交叉韧带重建中,螺钉和销子联合结构是否能改善胫骨固定?","authors":"Pierre Laumonerie, Meagan E Tibbo, Gregoire Laumond, Dominique Barbier, Pauline Assemat, Pascal Swider, Franck Accadbled","doi":"10.1007/s00590-021-03049-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aims of the present study were to compare the biomechanical properties of tibial fixation in hamstring-graft ACL reconstruction using interference screw and a novel combination interference screw and dowel construct.</p><p><strong>Material and methods: </strong>We compared the fixation of 30 (2- and 4-stranded gracilis and semitendinosis tendons) in 15 fresh-frozen porcine tibiae with a biocomposite resorbable interference screw (Group 1) and a screw and dowel construct (Group 2). Each graft was subjected to load-to-failure testing (50 mm/min) to determine maximum load, displacement at failure and pullout strength.</p><p><strong>Results: </strong>There were no significant differences between the biomechanical properties of the constructs. Multivariate analysis demonstrated that combination constructs (β = 140.20, p = 0.043), screw diameter (β = 185, p = 0.006) and 4-strand grafts (β = 51, p = 0.050) were associated with a significant increase in load at failure. Larger screw diameter was associated with increased construct stiffness (β = 20.15, p = 0.020).</p><p><strong>Conclusion: </strong>The screw and dowel construct led to significantly increased fixation properties compared to interference screws alone in a porcine model. Increased screw diameter and utilization of 4-strand ACL grafts also led to improvement in load-to-failure of the construct. However, this is an in vitro study and additional investigations are needed to determine whether the results are reproducible in vivo.</p><p><strong>Level of evidence: </strong>Level V; Biomechanical study.</p>","PeriodicalId":520619,"journal":{"name":"European journal of orthopaedic surgery & traumatology : orthopedie traumatologie","volume":" ","pages":"759-765"},"PeriodicalIF":1.5000,"publicationDate":"2022-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Does a combined screw and dowel construct improve tibial fixation during anterior cruciate ligament reconstruction?\",\"authors\":\"Pierre Laumonerie, Meagan E Tibbo, Gregoire Laumond, Dominique Barbier, Pauline Assemat, Pascal Swider, Franck Accadbled\",\"doi\":\"10.1007/s00590-021-03049-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The aims of the present study were to compare the biomechanical properties of tibial fixation in hamstring-graft ACL reconstruction using interference screw and a novel combination interference screw and dowel construct.</p><p><strong>Material and methods: </strong>We compared the fixation of 30 (2- and 4-stranded gracilis and semitendinosis tendons) in 15 fresh-frozen porcine tibiae with a biocomposite resorbable interference screw (Group 1) and a screw and dowel construct (Group 2). Each graft was subjected to load-to-failure testing (50 mm/min) to determine maximum load, displacement at failure and pullout strength.</p><p><strong>Results: </strong>There were no significant differences between the biomechanical properties of the constructs. Multivariate analysis demonstrated that combination constructs (β = 140.20, p = 0.043), screw diameter (β = 185, p = 0.006) and 4-strand grafts (β = 51, p = 0.050) were associated with a significant increase in load at failure. Larger screw diameter was associated with increased construct stiffness (β = 20.15, p = 0.020).</p><p><strong>Conclusion: </strong>The screw and dowel construct led to significantly increased fixation properties compared to interference screws alone in a porcine model. Increased screw diameter and utilization of 4-strand ACL grafts also led to improvement in load-to-failure of the construct. However, this is an in vitro study and additional investigations are needed to determine whether the results are reproducible in vivo.</p><p><strong>Level of evidence: </strong>Level V; Biomechanical study.</p>\",\"PeriodicalId\":520619,\"journal\":{\"name\":\"European journal of orthopaedic surgery & traumatology : orthopedie traumatologie\",\"volume\":\" \",\"pages\":\"759-765\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2022-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European journal of orthopaedic surgery & traumatology : orthopedie traumatologie\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s00590-021-03049-2\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2021/6/14 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European journal of orthopaedic surgery & traumatology : orthopedie traumatologie","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s00590-021-03049-2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/6/14 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
目的:本研究的目的是比较干涉螺钉和一种新型干涉螺钉和榫结合结构在腘绳肌腱移植前交叉韧带重建中的胫骨固定的生物力学性能。材料和方法:我们比较了使用生物复合可吸收干涉螺钉(组1)和螺钉-钉结构(组2)固定15只新鲜冷冻猪胫骨的30根(2股和4股股薄筋和半腱膜肌腱)。每个接枝都进行了载荷-破坏测试(50 mm/min),以确定最大载荷、破坏时的位移和拉拔强度。结果:两种构造体的生物力学性能无明显差异。多因素分析表明,组合结构(β = 140.20, p = 0.043)、螺钉直径(β = 185, p = 0.006)和4股移植物(β = 51, p = 0.050)与失败时负荷显著增加相关。较大的螺钉直径与结构刚度增加相关(β = 20.15, p = 0.020)。结论:在猪模型中,螺钉和销钉结构比单纯干涉螺钉的固定性能显著提高。增加螺钉直径和使用4股前交叉韧带移植物也可以改善结构的负荷-失效。然而,这是一项体外研究,需要进一步的调查来确定结果是否在体内可重复。证据等级:V级;生物力学研究。
Does a combined screw and dowel construct improve tibial fixation during anterior cruciate ligament reconstruction?
Purpose: The aims of the present study were to compare the biomechanical properties of tibial fixation in hamstring-graft ACL reconstruction using interference screw and a novel combination interference screw and dowel construct.
Material and methods: We compared the fixation of 30 (2- and 4-stranded gracilis and semitendinosis tendons) in 15 fresh-frozen porcine tibiae with a biocomposite resorbable interference screw (Group 1) and a screw and dowel construct (Group 2). Each graft was subjected to load-to-failure testing (50 mm/min) to determine maximum load, displacement at failure and pullout strength.
Results: There were no significant differences between the biomechanical properties of the constructs. Multivariate analysis demonstrated that combination constructs (β = 140.20, p = 0.043), screw diameter (β = 185, p = 0.006) and 4-strand grafts (β = 51, p = 0.050) were associated with a significant increase in load at failure. Larger screw diameter was associated with increased construct stiffness (β = 20.15, p = 0.020).
Conclusion: The screw and dowel construct led to significantly increased fixation properties compared to interference screws alone in a porcine model. Increased screw diameter and utilization of 4-strand ACL grafts also led to improvement in load-to-failure of the construct. However, this is an in vitro study and additional investigations are needed to determine whether the results are reproducible in vivo.