SPECT/CT关节造影对疑似无菌性关节假体松动的诊断准确性。

IF 1.7 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Bo Bao, Crystal S Liu, Edward C O Masson, Jonathan T Abele
{"title":"SPECT/CT关节造影对疑似无菌性关节假体松动的诊断准确性。","authors":"Bo Bao,&nbsp;Crystal S Liu,&nbsp;Edward C O Masson,&nbsp;Jonathan T Abele","doi":"10.1186/s41824-021-00098-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the diagnostic accuracy of SPECT/CT arthrography in patients with suspected aseptic prosthesis loosening following hip and knee arthroplasty.</p><p><strong>Methods: </strong>A retrospective review of 63 SPECT/CT arthrogram studies (36 knees and 27 hips) between February 1, 2013, and July 1, 2018, was conducted. All patients underwent clinical and radiologic evaluation as part of their assessment for persistent pain following hip and knee arthroplasty. The detection of tracer activity along the bone-prosthetic interface on SPECT/CT suggests aseptic loosening. Operative assessment as well as clinical/radiologic follow-up at a minimum of 1 year was used as the reference standard.</p><p><strong>Results: </strong>The sensitivity and specificity of SPECT/CT for detection of aseptic loosening was 6/7 (86%) and 55/56 (98%), respectively. This gives a positive predictive value (PPV) of 6/7 (86%), a negative predictive value (NPV) of 55/56 (98%), and a diagnostic accuracy of 61/63 (97%).</p><p><strong>Conclusion: </strong>SPECT/CT arthrography has a high diagnostic accuracy (97%) in the evaluation of loosening of both hip and knee arthroplasties in patients with persistent post-procedural pain.</p>","PeriodicalId":36160,"journal":{"name":"European Journal of Hybrid Imaging","volume":"5 1","pages":"4"},"PeriodicalIF":1.7000,"publicationDate":"2021-02-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8218161/pdf/","citationCount":"24","resultStr":"{\"title\":\"Diagnostic accuracy of SPECT/CT arthrography in patients with suspected aseptic joint prostheses loosening.\",\"authors\":\"Bo Bao,&nbsp;Crystal S Liu,&nbsp;Edward C O Masson,&nbsp;Jonathan T Abele\",\"doi\":\"10.1186/s41824-021-00098-y\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the diagnostic accuracy of SPECT/CT arthrography in patients with suspected aseptic prosthesis loosening following hip and knee arthroplasty.</p><p><strong>Methods: </strong>A retrospective review of 63 SPECT/CT arthrogram studies (36 knees and 27 hips) between February 1, 2013, and July 1, 2018, was conducted. All patients underwent clinical and radiologic evaluation as part of their assessment for persistent pain following hip and knee arthroplasty. The detection of tracer activity along the bone-prosthetic interface on SPECT/CT suggests aseptic loosening. Operative assessment as well as clinical/radiologic follow-up at a minimum of 1 year was used as the reference standard.</p><p><strong>Results: </strong>The sensitivity and specificity of SPECT/CT for detection of aseptic loosening was 6/7 (86%) and 55/56 (98%), respectively. This gives a positive predictive value (PPV) of 6/7 (86%), a negative predictive value (NPV) of 55/56 (98%), and a diagnostic accuracy of 61/63 (97%).</p><p><strong>Conclusion: </strong>SPECT/CT arthrography has a high diagnostic accuracy (97%) in the evaluation of loosening of both hip and knee arthroplasties in patients with persistent post-procedural pain.</p>\",\"PeriodicalId\":36160,\"journal\":{\"name\":\"European Journal of Hybrid Imaging\",\"volume\":\"5 1\",\"pages\":\"4\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2021-02-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8218161/pdf/\",\"citationCount\":\"24\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Hybrid Imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1186/s41824-021-00098-y\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Hybrid Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s41824-021-00098-y","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 24

摘要

目的:评价SPECT/CT关节造影对髋关节置换术后疑似无菌性假体松动的诊断准确性。方法:回顾性分析2013年2月1日至2018年7月1日期间的63例SPECT/CT关节造影研究(36例膝关节和27例髋关节)。所有患者都接受了临床和放射学评估,作为髋关节和膝关节置换术后持续疼痛评估的一部分。在SPECT/CT上沿骨-假体界面检测示踪剂活性提示无菌性松动。手术评估以及至少1年的临床/放射学随访作为参考标准。结果:SPECT/CT检测无菌性松动的敏感性为6/7(86%),特异性为55/56(98%)。阳性预测值(PPV)为6/7(86%),阴性预测值(NPV)为55/56(98%),诊断准确率为61/63(97%)。结论:SPECT/CT关节造影在评估髋关节和膝关节置换术后持续疼痛患者松动时具有很高的诊断准确性(97%)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Diagnostic accuracy of SPECT/CT arthrography in patients with suspected aseptic joint prostheses loosening.

Diagnostic accuracy of SPECT/CT arthrography in patients with suspected aseptic joint prostheses loosening.

Diagnostic accuracy of SPECT/CT arthrography in patients with suspected aseptic joint prostheses loosening.

Diagnostic accuracy of SPECT/CT arthrography in patients with suspected aseptic joint prostheses loosening.

Purpose: To evaluate the diagnostic accuracy of SPECT/CT arthrography in patients with suspected aseptic prosthesis loosening following hip and knee arthroplasty.

Methods: A retrospective review of 63 SPECT/CT arthrogram studies (36 knees and 27 hips) between February 1, 2013, and July 1, 2018, was conducted. All patients underwent clinical and radiologic evaluation as part of their assessment for persistent pain following hip and knee arthroplasty. The detection of tracer activity along the bone-prosthetic interface on SPECT/CT suggests aseptic loosening. Operative assessment as well as clinical/radiologic follow-up at a minimum of 1 year was used as the reference standard.

Results: The sensitivity and specificity of SPECT/CT for detection of aseptic loosening was 6/7 (86%) and 55/56 (98%), respectively. This gives a positive predictive value (PPV) of 6/7 (86%), a negative predictive value (NPV) of 55/56 (98%), and a diagnostic accuracy of 61/63 (97%).

Conclusion: SPECT/CT arthrography has a high diagnostic accuracy (97%) in the evaluation of loosening of both hip and knee arthroplasties in patients with persistent post-procedural pain.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
European Journal of Hybrid Imaging
European Journal of Hybrid Imaging Computer Science-Computer Science (miscellaneous)
CiteScore
3.40
自引率
0.00%
发文量
29
审稿时长
17 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信