Kenneth J Ciuffreda, Mh Esther Han, Barry Tannen, Daniella Rutner
{"title":"视觉雪综合征:脑震荡/轻度创伤性脑损伤中不断发展的神经验光考虑。","authors":"Kenneth J Ciuffreda, Mh Esther Han, Barry Tannen, Daniella Rutner","doi":"10.2217/cnc-2021-0003","DOIUrl":null,"url":null,"abstract":"Visual snow syndrome (VSS) is a relatively rare, unusual and enigmatic medical condition [1–4]. It frequently occurs in patients with concussion/mild traumatic brain injury (C/mTBI) and other brain-related abnormalities [1–7]. VSS presents with a constellation of visual and non-visual problems. The hallmark symptom is the appearance of pixelated ‘visual snow’ (VS) occurring in a single plane in front of and throughout the visual field, either achromatic or chromatic in nature. Individuals diagnosed with VSS must also report two or more of the following four primary visual perceptual phenomena: photosensitivity, night vision problems (nyctalopia), palinopsia and enhanced entoptic imagery [1,2]. They frequently also report some of the following secondary visual and non-visual symptoms: photopsia, migraine, phonophobia, hyperacusis, cutaneous allodynia, tinnitus, balance disturbances and tremor [1,2]. Based on the patient’s case history and the aforementioned possible symptomatology, we have developed a VSS symptom questionnaire to assist in diagnosis, as well as to assess the effect of a therapeutic intervention [5]. This questionnaire is used in our Vision Rehabilitation Service. We have also proposed a range of basic and advanced vision tests to assist in better understanding VSS [5]. The presence of VS per se was reported as early as 1944 in association with the use of digitalis for heart problems [8]. However, it is only over the past decade that VSS has received considerable attention [1–7], with emphasis on C/mTBI. This has focused on defining the diagnostic criteria and related aspects. Unfortunately, there has been a paucity of reports related to treatment, which has been minimally successful; for example, the work of van Dongan et al. [9]. Hence we have taken a different, neuro-optometrically based, approach in our evolving clinical studies [5–7] – especially in the patient with C/mTBI – with promising results. This has included the use of specialized chromatic and achromatic tints and a saccadic tracking paradigm. Our primary focus has involved the use of specialized spectacle tints, typically of a chromatic nature [5–7]. Different tints are tested on a patient, and the one that best reduces the perceived intensity of the VS is dispensed, being incorporated into the spectacle refractive correction. In addition, this tint typically also reduces the patient’s photosensitivity, as well as the perceived intensity of the disturbing palinopsia, if either or both are present. Two commercially available tints found to be effective are BPI-Omega (Brain Power Miami, FL, USA) and FL-41 (Brain Power Miami). In an earlier medically based study [10], the Intuitive ColorimeterTM (Cerium Visual Technologies Tenterden, Kent, UK) was used to assess chromatic tint preferences in 12 individuals with VSS. Eleven of the individuals (92%) had a distinct, repeatable chromatic preference, typically in the blue–yellow color spectrum. We have also used the Intuitive Colorimeter [7] to customize precisely the patient’s preferred chromatic filtration (‘tint’)","PeriodicalId":37006,"journal":{"name":"Concussion","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-04-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8162163/pdf/","citationCount":"8","resultStr":"{\"title\":\"Visual snow syndrome: evolving neuro-optometric considerations in concussion/mild traumatic brain injury.\",\"authors\":\"Kenneth J Ciuffreda, Mh Esther Han, Barry Tannen, Daniella Rutner\",\"doi\":\"10.2217/cnc-2021-0003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Visual snow syndrome (VSS) is a relatively rare, unusual and enigmatic medical condition [1–4]. It frequently occurs in patients with concussion/mild traumatic brain injury (C/mTBI) and other brain-related abnormalities [1–7]. VSS presents with a constellation of visual and non-visual problems. The hallmark symptom is the appearance of pixelated ‘visual snow’ (VS) occurring in a single plane in front of and throughout the visual field, either achromatic or chromatic in nature. Individuals diagnosed with VSS must also report two or more of the following four primary visual perceptual phenomena: photosensitivity, night vision problems (nyctalopia), palinopsia and enhanced entoptic imagery [1,2]. They frequently also report some of the following secondary visual and non-visual symptoms: photopsia, migraine, phonophobia, hyperacusis, cutaneous allodynia, tinnitus, balance disturbances and tremor [1,2]. Based on the patient’s case history and the aforementioned possible symptomatology, we have developed a VSS symptom questionnaire to assist in diagnosis, as well as to assess the effect of a therapeutic intervention [5]. This questionnaire is used in our Vision Rehabilitation Service. We have also proposed a range of basic and advanced vision tests to assist in better understanding VSS [5]. The presence of VS per se was reported as early as 1944 in association with the use of digitalis for heart problems [8]. However, it is only over the past decade that VSS has received considerable attention [1–7], with emphasis on C/mTBI. This has focused on defining the diagnostic criteria and related aspects. Unfortunately, there has been a paucity of reports related to treatment, which has been minimally successful; for example, the work of van Dongan et al. [9]. Hence we have taken a different, neuro-optometrically based, approach in our evolving clinical studies [5–7] – especially in the patient with C/mTBI – with promising results. This has included the use of specialized chromatic and achromatic tints and a saccadic tracking paradigm. Our primary focus has involved the use of specialized spectacle tints, typically of a chromatic nature [5–7]. Different tints are tested on a patient, and the one that best reduces the perceived intensity of the VS is dispensed, being incorporated into the spectacle refractive correction. In addition, this tint typically also reduces the patient’s photosensitivity, as well as the perceived intensity of the disturbing palinopsia, if either or both are present. Two commercially available tints found to be effective are BPI-Omega (Brain Power Miami, FL, USA) and FL-41 (Brain Power Miami). In an earlier medically based study [10], the Intuitive ColorimeterTM (Cerium Visual Technologies Tenterden, Kent, UK) was used to assess chromatic tint preferences in 12 individuals with VSS. Eleven of the individuals (92%) had a distinct, repeatable chromatic preference, typically in the blue–yellow color spectrum. We have also used the Intuitive Colorimeter [7] to customize precisely the patient’s preferred chromatic filtration (‘tint’)\",\"PeriodicalId\":37006,\"journal\":{\"name\":\"Concussion\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-04-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8162163/pdf/\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Concussion\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2217/cnc-2021-0003\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Concussion","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2217/cnc-2021-0003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
Visual snow syndrome (VSS) is a relatively rare, unusual and enigmatic medical condition [1–4]. It frequently occurs in patients with concussion/mild traumatic brain injury (C/mTBI) and other brain-related abnormalities [1–7]. VSS presents with a constellation of visual and non-visual problems. The hallmark symptom is the appearance of pixelated ‘visual snow’ (VS) occurring in a single plane in front of and throughout the visual field, either achromatic or chromatic in nature. Individuals diagnosed with VSS must also report two or more of the following four primary visual perceptual phenomena: photosensitivity, night vision problems (nyctalopia), palinopsia and enhanced entoptic imagery [1,2]. They frequently also report some of the following secondary visual and non-visual symptoms: photopsia, migraine, phonophobia, hyperacusis, cutaneous allodynia, tinnitus, balance disturbances and tremor [1,2]. Based on the patient’s case history and the aforementioned possible symptomatology, we have developed a VSS symptom questionnaire to assist in diagnosis, as well as to assess the effect of a therapeutic intervention [5]. This questionnaire is used in our Vision Rehabilitation Service. We have also proposed a range of basic and advanced vision tests to assist in better understanding VSS [5]. The presence of VS per se was reported as early as 1944 in association with the use of digitalis for heart problems [8]. However, it is only over the past decade that VSS has received considerable attention [1–7], with emphasis on C/mTBI. This has focused on defining the diagnostic criteria and related aspects. Unfortunately, there has been a paucity of reports related to treatment, which has been minimally successful; for example, the work of van Dongan et al. [9]. Hence we have taken a different, neuro-optometrically based, approach in our evolving clinical studies [5–7] – especially in the patient with C/mTBI – with promising results. This has included the use of specialized chromatic and achromatic tints and a saccadic tracking paradigm. Our primary focus has involved the use of specialized spectacle tints, typically of a chromatic nature [5–7]. Different tints are tested on a patient, and the one that best reduces the perceived intensity of the VS is dispensed, being incorporated into the spectacle refractive correction. In addition, this tint typically also reduces the patient’s photosensitivity, as well as the perceived intensity of the disturbing palinopsia, if either or both are present. Two commercially available tints found to be effective are BPI-Omega (Brain Power Miami, FL, USA) and FL-41 (Brain Power Miami). In an earlier medically based study [10], the Intuitive ColorimeterTM (Cerium Visual Technologies Tenterden, Kent, UK) was used to assess chromatic tint preferences in 12 individuals with VSS. Eleven of the individuals (92%) had a distinct, repeatable chromatic preference, typically in the blue–yellow color spectrum. We have also used the Intuitive Colorimeter [7] to customize precisely the patient’s preferred chromatic filtration (‘tint’)