基于医学图像数据重建三维几何的不确定性估计

IF 0.5 Q4 ENGINEERING, MECHANICAL
Marc Horner, Stephen M Luke, Kerim O Genc, Todd M Pietila, Ross T Cotton, Benjamin A Ache, Zachary H Levine, Kevin C Townsend
{"title":"基于医学图像数据重建三维几何的不确定性估计","authors":"Marc Horner,&nbsp;Stephen M Luke,&nbsp;Kerim O Genc,&nbsp;Todd M Pietila,&nbsp;Ross T Cotton,&nbsp;Benjamin A Ache,&nbsp;Zachary H Levine,&nbsp;Kevin C Townsend","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Patient-specific computational modeling is increasingly used to assist with visualization, planning, and execution of medical treatments. This trend is placing more reliance on medical imaging to provide accurate representations of anatomical structures. Digital image analysis is used to extract anatomical data for use in clinical assessment/planning. However, the presence of image artifacts, whether due to interactions between the physical object and the scanning modality or the scanning process, can degrade image accuracy. The process of extracting anatomical structures from the medical images introduces additional sources of variability, e.g., when thresholding or when eroding along apparent edges of biological structures. An estimate of the uncertainty associated with extracting anatomical data from medical images would therefore assist with assessing the reliability of patient-specific treatment plans. To this end, two image datasets were developed and analyzed using standard image analysis procedures. The first dataset was developed by performing a \"virtual voxelization\" of a CAD model of a sphere, representing the idealized scenario of no error in the image acquisition and reconstruction algorithms (i.e., a perfect scan). The second dataset was acquired by scanning three spherical balls using a laboratory-grade CT scanner. For the idealized sphere, the error in sphere diameter was less than or equal to 2% if 5 or more voxels were present across the diameter. The measurement error degraded to approximately 4% for a similar degree of voxelization of the physical phantom. The adaptation of established thresholding procedures to improve segmentation accuracy was also investigated.</p>","PeriodicalId":52254,"journal":{"name":"Journal of Verification, Validation and Uncertainty Quantification","volume":"4 4","pages":""},"PeriodicalIF":0.5000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7448268/pdf/nihms-1572949.pdf","citationCount":"0","resultStr":"{\"title\":\"Towards Estimating the Uncertainty Associated with Three-Dimensional Geometry Reconstructed from Medical Image Data.\",\"authors\":\"Marc Horner,&nbsp;Stephen M Luke,&nbsp;Kerim O Genc,&nbsp;Todd M Pietila,&nbsp;Ross T Cotton,&nbsp;Benjamin A Ache,&nbsp;Zachary H Levine,&nbsp;Kevin C Townsend\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Patient-specific computational modeling is increasingly used to assist with visualization, planning, and execution of medical treatments. This trend is placing more reliance on medical imaging to provide accurate representations of anatomical structures. Digital image analysis is used to extract anatomical data for use in clinical assessment/planning. However, the presence of image artifacts, whether due to interactions between the physical object and the scanning modality or the scanning process, can degrade image accuracy. The process of extracting anatomical structures from the medical images introduces additional sources of variability, e.g., when thresholding or when eroding along apparent edges of biological structures. An estimate of the uncertainty associated with extracting anatomical data from medical images would therefore assist with assessing the reliability of patient-specific treatment plans. To this end, two image datasets were developed and analyzed using standard image analysis procedures. The first dataset was developed by performing a \\\"virtual voxelization\\\" of a CAD model of a sphere, representing the idealized scenario of no error in the image acquisition and reconstruction algorithms (i.e., a perfect scan). The second dataset was acquired by scanning three spherical balls using a laboratory-grade CT scanner. For the idealized sphere, the error in sphere diameter was less than or equal to 2% if 5 or more voxels were present across the diameter. The measurement error degraded to approximately 4% for a similar degree of voxelization of the physical phantom. The adaptation of established thresholding procedures to improve segmentation accuracy was also investigated.</p>\",\"PeriodicalId\":52254,\"journal\":{\"name\":\"Journal of Verification, Validation and Uncertainty Quantification\",\"volume\":\"4 4\",\"pages\":\"\"},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2019-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7448268/pdf/nihms-1572949.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Verification, Validation and Uncertainty Quantification\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, MECHANICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Verification, Validation and Uncertainty Quantification","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

摘要

特定于患者的计算建模越来越多地用于协助可视化、计划和执行医疗。这种趋势越来越依赖于医学成像来提供准确的解剖结构表征。数字图像分析用于提取解剖数据,用于临床评估/计划。然而,图像伪影的存在,无论是由于物理对象与扫描方式或扫描过程之间的相互作用,都会降低图像的精度。从医学图像中提取解剖结构的过程引入了额外的变异性来源,例如,当阈值化或沿着生物结构的明显边缘侵蚀时。因此,对从医学图像中提取解剖数据的不确定性的估计将有助于评估针对具体患者的治疗计划的可靠性。为此,开发了两个图像数据集,并使用标准图像分析程序进行了分析。第一个数据集是通过对一个球体的CAD模型进行“虚拟体素化”来开发的,代表了图像采集和重建算法中没有错误的理想场景(即完美扫描)。第二个数据集是通过使用实验室级CT扫描仪扫描三个球形球获得的。对于理想的球体,如果在直径上存在5个或更多的体素,则球体直径的误差小于或等于2%。测量误差降低到约4%的体素化程度的物理幻影。本文还研究了阈值分割方法的适应性,以提高分割精度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Towards Estimating the Uncertainty Associated with Three-Dimensional Geometry Reconstructed from Medical Image Data.

Towards Estimating the Uncertainty Associated with Three-Dimensional Geometry Reconstructed from Medical Image Data.

Towards Estimating the Uncertainty Associated with Three-Dimensional Geometry Reconstructed from Medical Image Data.

Towards Estimating the Uncertainty Associated with Three-Dimensional Geometry Reconstructed from Medical Image Data.

Patient-specific computational modeling is increasingly used to assist with visualization, planning, and execution of medical treatments. This trend is placing more reliance on medical imaging to provide accurate representations of anatomical structures. Digital image analysis is used to extract anatomical data for use in clinical assessment/planning. However, the presence of image artifacts, whether due to interactions between the physical object and the scanning modality or the scanning process, can degrade image accuracy. The process of extracting anatomical structures from the medical images introduces additional sources of variability, e.g., when thresholding or when eroding along apparent edges of biological structures. An estimate of the uncertainty associated with extracting anatomical data from medical images would therefore assist with assessing the reliability of patient-specific treatment plans. To this end, two image datasets were developed and analyzed using standard image analysis procedures. The first dataset was developed by performing a "virtual voxelization" of a CAD model of a sphere, representing the idealized scenario of no error in the image acquisition and reconstruction algorithms (i.e., a perfect scan). The second dataset was acquired by scanning three spherical balls using a laboratory-grade CT scanner. For the idealized sphere, the error in sphere diameter was less than or equal to 2% if 5 or more voxels were present across the diameter. The measurement error degraded to approximately 4% for a similar degree of voxelization of the physical phantom. The adaptation of established thresholding procedures to improve segmentation accuracy was also investigated.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.60
自引率
16.70%
发文量
12
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信