新方法,老问题-作用的对比增强光谱乳房x线摄影在乳腺癌的诊断波兰妇女。

IF 0.9 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Polish Journal of Radiology Pub Date : 2020-07-27 eCollection Date: 2020-01-01 DOI:10.5114/pjr.2020.97941
Katarzyna Steinhof-Radwańska, Anna Grażyńska, Anna Barczyk-Gutkowska, Maciej Kajor, Piotr Powązka, Andrzej Lorek, Ewa Szlachta-Świątkowska, Irmina Morawska, Karolina Okas, Zuzanna Lelek, Magdalena Bielińska, Iwona Gisterek, Beata Casańas, Joanna Pilch-Kowalczyk
{"title":"新方法,老问题-作用的对比增强光谱乳房x线摄影在乳腺癌的诊断波兰妇女。","authors":"Katarzyna Steinhof-Radwańska,&nbsp;Anna Grażyńska,&nbsp;Anna Barczyk-Gutkowska,&nbsp;Maciej Kajor,&nbsp;Piotr Powązka,&nbsp;Andrzej Lorek,&nbsp;Ewa Szlachta-Świątkowska,&nbsp;Irmina Morawska,&nbsp;Karolina Okas,&nbsp;Zuzanna Lelek,&nbsp;Magdalena Bielińska,&nbsp;Iwona Gisterek,&nbsp;Beata Casańas,&nbsp;Joanna Pilch-Kowalczyk","doi":"10.5114/pjr.2020.97941","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of the study was to evaluate spectral mammography (CESM) in diagnosing breast cancer, which is based on sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV).</p><p><strong>Material and methods: </strong>The study included a group of 547 women who underwent spectral mammography and histopathological verification of the lesion, previously seen in mammography and/or ultrasound. In the group of 547 women, 593 focal lesions were diagnosed. All CESM examinations were carried-out with a digital mammography device dedicated to performing dual-energy CESM acquisitions. An intravenous injection of 1.5 ml/kg of body mass of non-ionic contrast agent was performed.</p><p><strong>Results: </strong>The analysis includes 593 breast lesions, in this group cancer was detected in 327 (55.14%) lesions, and in 256 (43.17%) cases benign lesions were confirmed by histopathological examination and at least 12 months of observation. The method shows differentiation of benign and malignant lesions in the breast: sensitivity of 97.86%, specificity of 59.4%, PPV - 74.76%, NPV - 95.76%.</p><p><strong>Conclusions: </strong>Spectral mammography could be an ideal method to detect breast cancer. Thanks to the high NPV (95.76%), it facilitates the exclusion of cancer in situations where pathological contrast enhancement is not observed. The unsatisfactory specificity of the study (59.4%) would not make it safe to avoid a core needle biopsy of lesions that undergo contrast enhancement.</p>","PeriodicalId":47128,"journal":{"name":"Polish Journal of Radiology","volume":"85 ","pages":"e381-e386"},"PeriodicalIF":0.9000,"publicationDate":"2020-07-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/57/a2/PJR-85-41524.PMC7425219.pdf","citationCount":"6","resultStr":"{\"title\":\"The new method, the old problem - role of contrast-enhanced spectral mammography in the diagnosis of breast cancer among Polish women.\",\"authors\":\"Katarzyna Steinhof-Radwańska,&nbsp;Anna Grażyńska,&nbsp;Anna Barczyk-Gutkowska,&nbsp;Maciej Kajor,&nbsp;Piotr Powązka,&nbsp;Andrzej Lorek,&nbsp;Ewa Szlachta-Świątkowska,&nbsp;Irmina Morawska,&nbsp;Karolina Okas,&nbsp;Zuzanna Lelek,&nbsp;Magdalena Bielińska,&nbsp;Iwona Gisterek,&nbsp;Beata Casańas,&nbsp;Joanna Pilch-Kowalczyk\",\"doi\":\"10.5114/pjr.2020.97941\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The aim of the study was to evaluate spectral mammography (CESM) in diagnosing breast cancer, which is based on sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV).</p><p><strong>Material and methods: </strong>The study included a group of 547 women who underwent spectral mammography and histopathological verification of the lesion, previously seen in mammography and/or ultrasound. In the group of 547 women, 593 focal lesions were diagnosed. All CESM examinations were carried-out with a digital mammography device dedicated to performing dual-energy CESM acquisitions. An intravenous injection of 1.5 ml/kg of body mass of non-ionic contrast agent was performed.</p><p><strong>Results: </strong>The analysis includes 593 breast lesions, in this group cancer was detected in 327 (55.14%) lesions, and in 256 (43.17%) cases benign lesions were confirmed by histopathological examination and at least 12 months of observation. The method shows differentiation of benign and malignant lesions in the breast: sensitivity of 97.86%, specificity of 59.4%, PPV - 74.76%, NPV - 95.76%.</p><p><strong>Conclusions: </strong>Spectral mammography could be an ideal method to detect breast cancer. Thanks to the high NPV (95.76%), it facilitates the exclusion of cancer in situations where pathological contrast enhancement is not observed. The unsatisfactory specificity of the study (59.4%) would not make it safe to avoid a core needle biopsy of lesions that undergo contrast enhancement.</p>\",\"PeriodicalId\":47128,\"journal\":{\"name\":\"Polish Journal of Radiology\",\"volume\":\"85 \",\"pages\":\"e381-e386\"},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2020-07-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/57/a2/PJR-85-41524.PMC7425219.pdf\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Polish Journal of Radiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5114/pjr.2020.97941\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2020/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q4\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Polish Journal of Radiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5114/pjr.2020.97941","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2020/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 6

摘要

目的:评价基于敏感性、特异性、阳性预测值(PPV)和阴性预测值(NPV)的乳腺x线造影(CESM)诊断乳腺癌的价值。材料和方法:该研究包括547名妇女,她们接受了乳房x光检查和组织病理学检查,之前在乳房x光检查和/或超声检查中发现病变。在547名妇女中,诊断出593例局灶性病变。所有CESM检查均使用专用于双能CESM采集的数字乳房x线摄影设备进行。静脉注射非离子造影剂1.5 ml/kg体重。结果:本组共593例乳腺病变,其中检出癌327例(55.14%),经组织病理学检查及至少12个月观察证实良性病变256例(43.17%)。该方法鉴别乳腺良恶性病变的敏感性为97.86%,特异性为59.4%,PPV - 74.76%, NPV - 95.76%。结论:乳腺x线造影是一种理想的检测乳腺癌的方法。高净现值(95.76%)有助于在未观察到病理对比增强的情况下排除癌症。该研究的特异性(59.4%)不令人满意,因此不能安全地避免对进行对比增强的病变进行核心针活检。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

The new method, the old problem - role of contrast-enhanced spectral mammography in the diagnosis of breast cancer among Polish women.

The new method, the old problem - role of contrast-enhanced spectral mammography in the diagnosis of breast cancer among Polish women.

The new method, the old problem - role of contrast-enhanced spectral mammography in the diagnosis of breast cancer among Polish women.

The new method, the old problem - role of contrast-enhanced spectral mammography in the diagnosis of breast cancer among Polish women.

Purpose: The aim of the study was to evaluate spectral mammography (CESM) in diagnosing breast cancer, which is based on sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV).

Material and methods: The study included a group of 547 women who underwent spectral mammography and histopathological verification of the lesion, previously seen in mammography and/or ultrasound. In the group of 547 women, 593 focal lesions were diagnosed. All CESM examinations were carried-out with a digital mammography device dedicated to performing dual-energy CESM acquisitions. An intravenous injection of 1.5 ml/kg of body mass of non-ionic contrast agent was performed.

Results: The analysis includes 593 breast lesions, in this group cancer was detected in 327 (55.14%) lesions, and in 256 (43.17%) cases benign lesions were confirmed by histopathological examination and at least 12 months of observation. The method shows differentiation of benign and malignant lesions in the breast: sensitivity of 97.86%, specificity of 59.4%, PPV - 74.76%, NPV - 95.76%.

Conclusions: Spectral mammography could be an ideal method to detect breast cancer. Thanks to the high NPV (95.76%), it facilitates the exclusion of cancer in situations where pathological contrast enhancement is not observed. The unsatisfactory specificity of the study (59.4%) would not make it safe to avoid a core needle biopsy of lesions that undergo contrast enhancement.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Polish Journal of Radiology
Polish Journal of Radiology RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
2.10
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信