1型强直性肌营养不良和高心室易损性电生理评估:ICD是否正确?

Q3 Medicine
Giusy Sirico, Andrea Montisci, Francesco Secchi, Massimo Mantica
{"title":"1型强直性肌营养不良和高心室易损性电生理评估:ICD是否正确?","authors":"Giusy Sirico,&nbsp;Andrea Montisci,&nbsp;Francesco Secchi,&nbsp;Massimo Mantica","doi":"10.36185/2532-1900-006","DOIUrl":null,"url":null,"abstract":"<p><p>A significant number of sudden death (SD) is observed in myotonic dystrophy (DM1) despite pacemaker implantation and some consider the ICD to be the preferential device in patients with conduction disease. According to the latest guidelines, prophylactic ICD implantation in patients with neuromuscular disorder should follow the same recommendations of non-ischemic dilated cardiomyopathy, being reasonable when pacing is needed. We here report a case of DM1 patient who underwent ICD implantation even in the absence of conduction disturbances on ECG and ventricular dysfunction/fibrosis at cardiac magnetic resonance. The occurrence of syncope, non-sustained ventricular tachycardias at 24-Holter ECG monitoring and a family history of SD resulted associated with ventricular fibrillation inducibility at electrophysiological study, favouring ICD implantation. On our advice, DM1 patient with this association of SD risk factors should be targeted for ICD implantation.</p>","PeriodicalId":35953,"journal":{"name":"Acta Myologica","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/a8/cc/am-2020-01-32.PMC7315899.pdf","citationCount":"0","resultStr":"{\"title\":\"Myotonic dystrophy type 1 and high ventricular vulnerability at the electrophysiological evaluation: ICD yes or not?\",\"authors\":\"Giusy Sirico,&nbsp;Andrea Montisci,&nbsp;Francesco Secchi,&nbsp;Massimo Mantica\",\"doi\":\"10.36185/2532-1900-006\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A significant number of sudden death (SD) is observed in myotonic dystrophy (DM1) despite pacemaker implantation and some consider the ICD to be the preferential device in patients with conduction disease. According to the latest guidelines, prophylactic ICD implantation in patients with neuromuscular disorder should follow the same recommendations of non-ischemic dilated cardiomyopathy, being reasonable when pacing is needed. We here report a case of DM1 patient who underwent ICD implantation even in the absence of conduction disturbances on ECG and ventricular dysfunction/fibrosis at cardiac magnetic resonance. The occurrence of syncope, non-sustained ventricular tachycardias at 24-Holter ECG monitoring and a family history of SD resulted associated with ventricular fibrillation inducibility at electrophysiological study, favouring ICD implantation. On our advice, DM1 patient with this association of SD risk factors should be targeted for ICD implantation.</p>\",\"PeriodicalId\":35953,\"journal\":{\"name\":\"Acta Myologica\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/a8/cc/am-2020-01-32.PMC7315899.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Myologica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.36185/2532-1900-006\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Myologica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.36185/2532-1900-006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

尽管植入了起搏器,但在肌强直性营养不良(DM1)患者中仍观察到大量猝死(SD),一些人认为ICD是传导疾病患者的首选装置。根据最新的指南,神经肌肉疾病患者预防性ICD植入应遵循与非缺血性扩张型心肌病相同的建议,在需要起搏时是合理的。我们在此报告一例DM1患者,即使在没有心电图传导障碍和心脏磁共振心室功能障碍/纤维化的情况下,也接受了ICD植入。在电生理研究中,24小时动态心电图监测中晕厥、非持续性室性心动过速和SD家族史的发生与心室颤动的诱发性相关,有利于ICD植入。根据我们的建议,具有这种SD危险因素关联的DM1患者应该有针对性地植入ICD。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Myotonic dystrophy type 1 and high ventricular vulnerability at the electrophysiological evaluation: ICD yes or not?

A significant number of sudden death (SD) is observed in myotonic dystrophy (DM1) despite pacemaker implantation and some consider the ICD to be the preferential device in patients with conduction disease. According to the latest guidelines, prophylactic ICD implantation in patients with neuromuscular disorder should follow the same recommendations of non-ischemic dilated cardiomyopathy, being reasonable when pacing is needed. We here report a case of DM1 patient who underwent ICD implantation even in the absence of conduction disturbances on ECG and ventricular dysfunction/fibrosis at cardiac magnetic resonance. The occurrence of syncope, non-sustained ventricular tachycardias at 24-Holter ECG monitoring and a family history of SD resulted associated with ventricular fibrillation inducibility at electrophysiological study, favouring ICD implantation. On our advice, DM1 patient with this association of SD risk factors should be targeted for ICD implantation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Acta Myologica
Acta Myologica Medicine-Cardiology and Cardiovascular Medicine
CiteScore
3.70
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信