{"title":"固相萃取-柱切换LC-MS/MS分析人粪便中血清素。","authors":"Yukiko Hirabayashi, Kiminori Nakamura, Tsuyoshi Sonehara, Daisuke Suzuki, Satoru Hanzawa, Yu Shimizu, Tomoyasu Aizawa, Koshi Nakamura, Akiko Tamakoshi, Tokiyoshi Ayabe","doi":"10.5702/massspectrometry.A0081","DOIUrl":null,"url":null,"abstract":"<p><p>Serotonin, an important neurotransmitter, is produced mainly in intestines, and serotonin levels in feces can be an indicator of the intestinal environment. Human feces, however, contain a large amount of contaminants, which vary widely owing to food contents and the intestinal environment, and these contaminants would be expected to interfere with the determination of serotonin levels in human feces. To remove these contaminants and determine serotonin levels, we developed a new method using solid phase extraction (SPE) and column-switching LC-MS/MS. Serotonin, labeled with a stable isotope, was added to human feces samples prior to SPE as an internal standard to correct for individual differences in matrix effects. The recovery rate for SPE was 55.9-81.0% (intraday) and 56.5-78.1% (interday) for feces from two subjects. We analyzed 220 fecal samples from 96 subjects including 76 pregnant and post-delivery women. The endogenous serotonin content per unit weight of dried feces was 0.09-14.13 ng/mg for pregnant and post-delivery women and 0.30-9.93 ng/mg for the remaining subjects.</p>","PeriodicalId":18243,"journal":{"name":"Mass spectrometry","volume":"9 1","pages":"A0081"},"PeriodicalIF":0.0000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.5702/massspectrometry.A0081","citationCount":"2","resultStr":"{\"title\":\"Analysis of Serotonin in Human Feces Using Solid Phase Extraction and Column-Switching LC-MS/MS.\",\"authors\":\"Yukiko Hirabayashi, Kiminori Nakamura, Tsuyoshi Sonehara, Daisuke Suzuki, Satoru Hanzawa, Yu Shimizu, Tomoyasu Aizawa, Koshi Nakamura, Akiko Tamakoshi, Tokiyoshi Ayabe\",\"doi\":\"10.5702/massspectrometry.A0081\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Serotonin, an important neurotransmitter, is produced mainly in intestines, and serotonin levels in feces can be an indicator of the intestinal environment. Human feces, however, contain a large amount of contaminants, which vary widely owing to food contents and the intestinal environment, and these contaminants would be expected to interfere with the determination of serotonin levels in human feces. To remove these contaminants and determine serotonin levels, we developed a new method using solid phase extraction (SPE) and column-switching LC-MS/MS. Serotonin, labeled with a stable isotope, was added to human feces samples prior to SPE as an internal standard to correct for individual differences in matrix effects. The recovery rate for SPE was 55.9-81.0% (intraday) and 56.5-78.1% (interday) for feces from two subjects. We analyzed 220 fecal samples from 96 subjects including 76 pregnant and post-delivery women. The endogenous serotonin content per unit weight of dried feces was 0.09-14.13 ng/mg for pregnant and post-delivery women and 0.30-9.93 ng/mg for the remaining subjects.</p>\",\"PeriodicalId\":18243,\"journal\":{\"name\":\"Mass spectrometry\",\"volume\":\"9 1\",\"pages\":\"A0081\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.5702/massspectrometry.A0081\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Mass spectrometry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5702/massspectrometry.A0081\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2020/3/31 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"Physics and Astronomy\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Mass spectrometry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5702/massspectrometry.A0081","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2020/3/31 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Physics and Astronomy","Score":null,"Total":0}
Analysis of Serotonin in Human Feces Using Solid Phase Extraction and Column-Switching LC-MS/MS.
Serotonin, an important neurotransmitter, is produced mainly in intestines, and serotonin levels in feces can be an indicator of the intestinal environment. Human feces, however, contain a large amount of contaminants, which vary widely owing to food contents and the intestinal environment, and these contaminants would be expected to interfere with the determination of serotonin levels in human feces. To remove these contaminants and determine serotonin levels, we developed a new method using solid phase extraction (SPE) and column-switching LC-MS/MS. Serotonin, labeled with a stable isotope, was added to human feces samples prior to SPE as an internal standard to correct for individual differences in matrix effects. The recovery rate for SPE was 55.9-81.0% (intraday) and 56.5-78.1% (interday) for feces from two subjects. We analyzed 220 fecal samples from 96 subjects including 76 pregnant and post-delivery women. The endogenous serotonin content per unit weight of dried feces was 0.09-14.13 ng/mg for pregnant and post-delivery women and 0.30-9.93 ng/mg for the remaining subjects.